Web Analytics Made Easy - StatCounter

Amf Relay Tenders

Get complete information related to latest Amf Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Amf Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Amf Relay Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :40916587 Due date: 11 Jul, 202511 Jul, 2025 1.76 Lacs
Tender For supply of electrical and misc items d d - clamp grndg gi 70 sqmm , crc cleaner contact 400ml , earth leakage relay with cbct 12v 1-750ma , earth leakage relay digital 110v 50-750ma , relay overload thermal 80-110a 550 v ac

State Government

CTN :40899567 Due date: 07 Jul, 202507 Jul, 2025 5.00 Lacs
Tender For urgent work at kagdi pickup weir during flood season for the year 2025 - unskilled beldar/ coolie / chowkidar / water man / earth- dresser - unskilled beldar/ coolie / chowkidar / water man / earth- dresser, providing and filling/ replacing hydraulic oil of approved quality up to the required gauge level including cost of all materials, machinery, labour etc. complete., supplying of well stitched earth filled bags of capacity, weigh not less than 40 kg per bag at site etc. complete. plastic bag, empty bag of 50 kg capacity in good condition plastic / polythene, cost of diesel, painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work, hydraulic excavator/ loader like jcb/ poclain, hitachi etc. with all accessories (for actual site working, idle period) having bucket capacity above 0.40 & upto 0.75 cum without gst/ profit, p/laying isi marked p.v.c. insulated submersible cable confirming to(is:694) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.90 % purity copper, stranding in acc. to is:8130/iec 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation pvc type a/c/d , flame retardant as per is 10810-53, better amperage rating as per is:3961 part 5, existing pipe / open trench / cable tray / on surface including making connection etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr - 6.0 sq.mm 3 core flat / round, p & f of direct on line (dol) / star - delta starter as per iec type-2 co-ordination chart of oem in existing panel with circuit breaker having inbuilt overload protection or separate thermal overload relay , short circuit, phase loss protection, suitable contactors, including wiring between switchgears, indicating lamps for r,y,b,on,off, push button for on, off, volt meter, ammeter, selector switch for local/remote, auto/manual/off operation. cast resin cts, provision for potential free contacts making connection, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . direct on line (dol) starter with following motor rating - motor rating 4.0 kw

Central Government/Public Sector

CTN :39986315 Due date: 02 Jul, 202502 Jul, 2025 NA
Tender For bid to ras bid to ras corrigendum : supply of e4953005 thermal overload relay 01-bp9049113796- thermal overload relay with contactor 240v ac as per

Central Government/Public Sector

CTN :40754126 Due date: 04 Jul, 202504 Jul, 2025 1.13 Crore
Tender For corrigendum : supply of spares for abc electricals pvt ltd make flpstarter drillcontrolpanel gateendbox lightingtransformer - chasis wired up with all components fdb 100a dol , isolator reversing 300a fdb 101 c dol , sensetive earth leakage relay up to 750 ma fdb 114ma dol , main contactor 90 150 hp fdb 102 b dol , main contactor kit for 90 150 hp fdb 102 b2 dol , thermal overload ct operated fdb 109bn dol , isolator reversing 300a fsd 101c sds , internal chasis wired up 150kw 200hp fsd 136 sds , contactor for 100 175 hp fsd 102a sds , contactor kit for 100 175 hp fsd 102 a2 sds , contactor for 190 250 hp fsd 102b sds , transformer panel with all components but without transformer , transformer only , electromagnetic earth leakage system , earth leakage relay , pilot relay , bridge rectifier unit , diode , condenser , relay base with wiring , hrc fuse base with carrier , main contactor 25 amps , contactor spare kit 25 amp , thermal overload relay , neutral resistor , resistance for pilot relays , test reset microswitch , leakage indication lamp , leakage indication lamp holder , 30a restrained plug and socket complete , terminal with insulator bushing , bush insulator for terminal , isolator switch 40 amps , front cover bolt , top cover bolt , sensitive earth leakage relay up to 750 ma , sensitive cbt for 750 ma earth leakage relay , mechanical latch type earth leakage relay with contact block , isolator reversing 200a , isolator reversing 300 a , copper busbar 300a with sleeving r y b , 150a restrained plug and socket complete , main contactor 200 amps , auxiliary contactor , magnetic overload relay , sensitive cbt for earth leakage relay 750 ma , selenium bridge rectifier , auxiliary transformer 100va , auxiliary transformer 150va , auxiliary transformer 250va , ct for overload , test microswitch , start stop microswitch , chasis wiring complete with all components including elr cbct , single phase preventor , plug and socket assy. comp. 200 amp sdl side , plug and socket assy. comp. 200 amp geb side , pt for lighting transformer 400va 550v 12v 24v sdl side , fail safe relay to ensure continuity between neutral and the ground , transformer panel complete with all component without transformer , internal chasis wired up with all protections , control transformer , terminal with insulatar incoming throughgoing interconnecting , outgoing terminal , copper busbar with sleeving r y b , isolator switch , earth leakage relay sensitive up to 750 ma , throughgoing cable box with gland and lead cone , sensitive cbt for 750 ma earth leakage relay

Central Government And Public Sector

CTN :40885797 Due date: 21 Jul, 202521 Jul, 2025 87.99 Lacs
Tender For supply of providing and fixing of lightning conductor finial. , jointing copper or g.i. tape with another copper or g i tape , providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall , providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess , repairing rewinding of 1 hp capacity centrifugal pump , repairing rewinding of 2 hp capacity centrifugal pump , repairing rewinding of 3 hp capacity centrifugal pump set , repairin rewinding of 5 hp capacity centrifugal pump set , repairing rewinding of 1.5 hp capacity submersible pumpset , repairing rewinding of 2 hp capacity submersible pumpset , repairing rewinding of 3 hp capacity submersible pumpset , repairing rewinding of 5 hp capacity submersible pumpset , sitc of submersible pumpset of 2 hp water filled , sitc of submersible pumpset of 4 hp water filled , lifting and lowing of submersible or borewell pump upto 5 hp alongwith gi pipe , lifting and lowing of submersible or borewell pump upto 5 hp alongwith hdpe pipe , repairing rewinding of 2 hp sump pump set , repairing rewinding of 3 hp sump pump set , repairing rewinding of 5 hp sump pump , replacement of faulty foot valve of size 40 mm dia , replacement of faulty foot valve of size 50 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 20 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 40 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 50 mm dia , replacement of nrv with new nrv made up of brass of size 40 mm dia , replacement of nrv with new nrv made up of brass of size 50 mm dia , supplying and fixing 20 mm dia b class medium g.i pipe , supplying and fixing 40 mm dia b class medium g.i pipe , supplying and fixing 50 mm dia b class medium g.i pipe , supplying and fixing 20 mm dia heavy duty upvc pipe , supplying and fixing 40 mm dia heavy duty upvc pipe , supplying and fixing 50 mm dia heavy duty upvc pipe , replacement 3 pole power contactors type mnx 12 , replacement 3 pole power contactors type mnx22 , replacement of mounting add on aux. contact block suitable for 9 a to 30 a , replacement of thermal overload relay suitable for mnx contactor range from 0.2 a to 23 a , supplying of 3 x 2.5 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 4 x 16 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 3.5 x 35 sq. mm aluminum conductor cable of 1.1kv grade , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size //bid details 3 / 138 upto 35 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on wall surface , s and m end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm al cable. , s and

Central Government And Public Sector

CTN :40885884 Due date: 21 Jul, 202521 Jul, 2025 87.99 Lacs
Tender For supply of providing and fixing of lightning conductor finial. , jointing copper or g.i. tape with another copper or g i tape , providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall , providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess , repairing rewinding of 1 hp capacity centrifugal pump , repairing rewinding of 2 hp capacity centrifugal pump , repairing rewinding of 3 hp capacity centrifugal pump set , repairin rewinding of 5 hp capacity centrifugal pump set , repairing rewinding of 1.5 hp capacity submersible pumpset , repairing rewinding of 2 hp capacity submersible pumpset , repairing rewinding of 3 hp capacity submersible pumpset , repairing rewinding of 5 hp capacity submersible pumpset , sitc of submersible pumpset of 2 hp water filled , sitc of submersible pumpset of 4 hp water filled , lifting and lowing of submersible or borewell pump upto 5 hp alongwith gi pipe , lifting and lowing of submersible or borewell pump upto 5 hp alongwith hdpe pipe , repairing rewinding of 2 hp sump pump set , repairing rewinding of 3 hp sump pump set , repairing rewinding of 5 hp sump pump , replacement of faulty foot valve of size 40 mm dia , replacement of faulty foot valve of size 50 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 20 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 40 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 50 mm dia , replacement of nrv with new nrv made up of brass of size 40 mm dia , replacement of nrv with new nrv made up of brass of size 50 mm dia , supplying and fixing 20 mm dia b class medium g.i pipe , supplying and fixing 40 mm dia b class medium g.i pipe , supplying and fixing 50 mm dia b class medium g.i pipe , supplying and fixing 20 mm dia heavy duty upvc pipe , supplying and fixing 40 mm dia heavy duty upvc pipe , supplying and fixing 50 mm dia heavy duty upvc pipe , replacement 3 pole power contactors type mnx 12 , replacement 3 pole power contactors type mnx22 , replacement of mounting add on aux. contact block suitable for 9 a to 30 a , replacement of thermal overload relay suitable for mnx contactor range from 0.2 a to 23 a , supplying of 3 x 2.5 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 4 x 16 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 3.5 x 35 sq. mm aluminum conductor cable of 1.1kv grade , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size //bid details 3 / 138 upto 35 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on wall surface , s and m end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm al cable. , s and

CTN :40843055 Due date: 23 Jul, 202523 Jul, 2025 NA
Tender For supply of material and tools for electrical maintenance - self-adhesive pvc insulation tape 6.5m roll , aaa size alkaline battery cell , aa size alkaline battery cell , self bonding electrical tape 9.1m roll , 11 kv 95 sqmm aluminium straight through jointing kit , switch disconnector fuse unit havells kompact plus 415 v 50 hz 250a , switch disconnector fuse unit havells kompact plus 415v 50 hz 125a , outdoor isolator junction box 320 a , outdoor isolator junction box 100 a , draw out type power control centre panel pcc panel , led tube light , 4pin 18w led light , 4 pin led light holder , 2 feet led batten , ding dong calling bell , 16a pvc switchboard , 1.1 kv flexible aluminium cable 2cx4sq.mm , 1.5sq.mm single core insulated copper wire , 2.5 sqmm single core insualted copper wire , 3c x 2.5sq.mm flexible copper cable , heavy duty ceiling fan 1200mm , heavy duty metallic exhaust fan 300mm , bolted type high break hrc fuse 63amp , blade type high break hrc fuse 250 amp , bolted type high break hrc fuse 125 amp , cylindrical type hrc fuse 2amp , laresen turbo make contactor for timer panel , larsen turbo make mu402p contactor , sdz5 relay for mug40 star delta starter , ml3 contactor for mug40 starter , mn5 thermal overload relay for mug40 starter , calling bell switch legerand mylinc , 16a switch legerand mylinc , 6 a switch legerand mylinc , 6a or 16 a socket legerand mylinc , 20a switch anchor roma , fan regulator anchor roma , 10a 5pin socket anchor roma , 25a 3 pin socket anchor roma , calling bell switch anchor roma , 25a sp mini mcb c series havells , 25a 3 pin socket crabtree athena , 6a 1way switch legrand arteor , 20a switch legrand arteor , 6a 5pin socket legrand arteor , 6a or 16a 3pin socket legrand arteor , fan regulator legrand arteor , calling bell switch legrand arteor , 10a switch havells reo bliss , 25a switch havells reo bliss , calling bell switch havells reo bliss , fan regulator havells reo bliss , 6a 5pin socket havells reo bliss , 6a or 16a 3pin socket havells reo bliss , 6a switch legrand britzy , 16a switch legrand britzy , fan regulator legrand britzy , 6a 3pin socket legrand britzy , 6a or 16a 3pin socket legrand britzy , 20a metal plug for industrial socket , ms china screw 1.5 inches , batten holder , havells air circuit breaker titania e series , led light driver for 2 x 2 light 36 w , 2 x 2 36 w flase ceiling led light , casing caping , flexible pipe 20 sqmm , isolator 4 pole 63 a , rccb 4 pole 63 a , 1 pole 16 a mcb , 1 pole 32 a mcb , puff seal foam , crc , capacitor 2.5 microfarad , havells hca0025 40 a 2 pole contactor , voltage stablizer , led bulb 12 w , cable cutter knife taparia , street lights with driver circuit 45 w , flood light 120 w , a type aluminium ladder , digital energy meter 3 phase class 1 40-60 a , micom p111 numerical idmt protection relay , tcs relay , sitc of main lt mccb panel

corporations/Associations/Others

CTN :40818665 Due date: 14 Jul, 202514 Jul, 2025 9.47 Lacs
Tender For procurement of consumable items and general spares for miscellaneous equipment along with safety items (ppe) for dhalipur power house - consumable, general spare and ppe items, old dhoties dully washed 3 to 5 meter long, old cotton dhoties washed/cleaned , length not less than 3 meter, width not less than 1 meter, white cotton cloth ( jute ) dry & clean thread waste ( white ) of spinning / weaving mill in good condition., white markin for cleaning purpose, high capability property to absorb oil, water and other liquid, 100 percent cotton, white texture, excellent strength,, jute carpet roll (tat patti) having a width-01 meter, modacrylic coverall / protex coverall flame resistant, colour blue,or grey size-l to xxl(3nos.of each size),disposable fabric: flamex (55% modacrylic, 43% cotton 2% antistatic)make-3m, wire braded flexible hose pipe id-25 mm,pressure range-0 to 10 kg/cm ,colour- black.make-mithra italia flex,global,polyhose, aira make nrv 15 mm ,high pressure 0-100 kg/cm , body-ss ,ends-screwed (f) to bsp, 1/2 ball valve ,pressure range-0 to 100 kg/cm ,3 piece ball valve ,body-ss make-zoloto/aira,f/b-r/b=f/b,end type-se,f to e=64 mm, l&t make fn 63 tpn/fp ce switch with enclosure sk90484 with interior fuse unit,, l&t make hrc fuse cylindrical type 63 amp cat-sf90159, l&t make mnx 32 power contactors 240v ac (3 pole),model no-cs94111dooo, l&t make mnx contactor 95a 3p 415v ac ac-3 ,aux supply-415v ac coil, freq-50/60 hz,model no-cs94136dooo, l&t make mnx contactor 70a 3p 415v ac ac-3 ,aux supply-415v ac coil,freq-50/60 hz,model no-cs97076dooo, l&t make mnx contactor 50a 3p 415v ac ac-3, aux supply-415v ac coil,freq-50/60 hz,model no-cs97075dooo, l&t make mnx contactor 12 a 3p 415v ac ac-3, aux supply-415v ac coil,freq-50/60 hz,model no-cs94109booo, siemens make contactor relay 4no 24v dc,model-3rh214001bb40, l&t make 66-110 a thermal overload relays for mnx contractor, model no-ss94137ooko, l&t make motor protection relay mpr300,240v ac,o/l range (a): 32-88 a,aux supply-240 v ac, l&t make mnx-a1 add on block.2no+2nc 4 poles contactor, sku:cs94114oooo, gic make sm 301,single phase preventer relay,protects against phase loss, phase reversal & phase asymmetry, gic make sm 800 supply monitoring series relay,model-gicdma220,phase and voltage control,voltage-85-300 v ac/dc,relay out put -2 c/o,monitoring of under-over voltage & frequency in 3 phase systems for line/phase voltage.monitoring of phase loss, phase sequence, phase asymmetry & neutral fail. measure true rms ac voltage. self & auxiliary power devices.configurable power on delay, off delay & on delay., gic make-multifunction electronic timer relay,model-gic-2aadt5 micron 225,24 - 240 v ac/dc,mounting type-base / din rail, switzer make pressure switch model-711, pressure range-0 to 100 bar ,output ac=100v-240v ac,output -18 v to 36 v dc,sensor material-ss 316,process connection-1/2 npt (m), regulated power supply unit, incoming voltage-100 vac to 240 vac, 140 vdc to 340 vdc ,stable output-voltage (v dc): 24.output current (amp): 10,output power (watt): 240,line regulation: 0.5% (full load).load regulation: 1% (230 vac i/p).make-schneider,abb, ball valve 25 mm ,body-ss- 316,pressure range-0 to 100 psi, end connection type-threaded,make-skilt,leader,aira, 40mm, 3 piece design lever operated flanged end ball valve,body test pressure-440 psi,thread type-bsp female,body-ss, length f to f=175 mm, make-universal,shreeram engineers ,zoloto,aira, 40amp double pole rcbo,voltage-230v ac,sensitivity-30ma,make-havells,abb, 3 phase 30 h.p automatic star-delta starter with short circuit protection ,relay range:28-40 a , model-ihhdsdxc,contactor rating: 50 a,full load line current: 43.50 a,full load phase current: 25.12 a,tp mcb rating (a): 100 a make -havells, ac control relay, model-ca2kn31m7,3 no 1nc,coil voltage-220 v ac,make-schneider, ac control relay, model-ca2kn31m7,3 no 1nc,coil voltage-110 v dc,make-schneider, dc

CTN :40811609 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For supply of ngr monitoring fail safe relay , planetory pinion 70 teeth , numerical idmt relay , clutch band assly , thermal overload relay , earth leakage relay with cbct , pt , isolator fixed contact set , isolator moving contact set

Corporations / Associations / Others

CTN :40800821 Due date: 12 Jul, 202512 Jul, 2025 8.21 Lacs
Tender For tender for supply of lv switchgears d d - auxiliary contact block front mounting 1no+1nc mnxa2 make l&t , contactor ml10 2no+2nc coil voltage 240 volts make l&t , contactor mnx265 2no+2nc coil volt 220/240v ac catalouge no. cs941420000 make l&t , auxiliary contact block 1no+1nc for 9a l&t contactor mnx9 , auxillary contactor 2no+2nc mn022e volt 240v ac catalouge no. ss94667 make l&t , auxiliary contact block mnxa1 2no+2nc make l&t , mccb 200a tp with rotary operating model dh100 along with aux contact make l&t , mccb 630a tp model dh630 make l&t , thermal overload relay 3-5a model mnxr3 make l&t , thermal overload relay 45-75a model mnxr4 make l&t , thermal overload relay 6-32a model mnxr3 make l&t , thermal overload relay 30-50a model mnx make l&t , thermal over load relay 65-110 amp model mn5 make l&t , thermal overload relay 90-450a mnxr5 make l&t , thermal over load relay 3-5 amp model- mn2 make l&t wall mounted , contactor mnx 80 coil voltage 240 v ac with add on block mnx-a1 2no 2nc , thermal over load relay 3.5 a to 5 a wall mounted , thermal over load relay 2.4 a to 3.2 a , contactor mnx 110 coil voltage 240 v ac , mccb 630a with 24v dc un coil and alarm+aux. contact model ns630n make merlin gerin , mccb 12.5 a ns100h3p basic frame(29004) ma-unit-ma12.5(29123) extended rotary handle(29338) aux.sw(29450) -2nos make merlin gerin , mpcb ns100sx3p35854 40a 3p ac tmd-unit extended rotary handle (btp29338) aux .sw(of 29450) 2n0s make merlin gerin , mccb 80a 3pole ac ns100sx3p35851 tmd-unit extended rotary handle (btp29338) aux.sw(of29450)-2nos. make merlin gerin , mccb 80a ns80hma3p28100 3p ma-unit extended rotary handle (28052) aux sw(29450) -2nos make merlin gerin , mccb 100a 10ka 415v ac tp incomer mccb with on/trip c/o model nks100r 3p make merlin gerin , mccb 150a ns160sx3p91601 3p ma-unit extended rotary handle (btp29338) aux sw (of29450) -2nos make merlin gerin , mccb 200a nks 200a 10ka dc model nks200r 3p make merlin gerin , mccb 220a ns250sx3p92601 3p ma-unit 220a extended rotary handle (btp29338) aux.sw/of-29450) -2nos make merlin gerin , moulded case circuit breaker 32a tm 32 d , moulded case circuit breaker 16a tm 16 d , contactor lc1e200 2no+2nc coil 240v make schneider , thermal overload relay 30-40 amp model lre3 make schneider , contactor lc1d09 1no+1nc coil voltage 220v make telemecanique , contactor lc1-d098f7 4 pole 20a 2n0-2nc coil voltage 110v make telemecanique , contactor lc1d1506f7 3p 150a 110vac 1no+1nc make telemecanique , add on contact lad-n22 2no+2nc make telemecanique , aux contactor cad32md 3no+2nc coil voltage 220vdc. , add on block 1no+3nc ladn13 make telemecanique , add on block 3no+1nc ladn31 make telemecanique , mpcb gv2-p16 9-14a aux/fault contact (gv-ad1010) padlock external ique operatorigv2-ap01) make telemecanique , contactor 3tf46 2no+2nc coil voltage 415 volt make siemens , contactor 85 amp 2no+2nc coil voltage 415 volt model 3tf49 make siemens , contactor 3tf50 2no+2nc coil voltage 230 volts make siemens , mccb 32 amp model mo-3kl47301ya00 make siemens , mccb 200 amp model 3kl54-30-1ya00 make siemens , thermal overload relay 1.4 to 10a model 3ua50-00-0e make siemens , thermal over load relay 2.5-3.5 amp model 3ua5200-1e make siemens , thermal overload relay 85-135 amp model 3ua6230-5a make siemens , aux contactor 220v ac coil 10a 2no+2nc3th3022-0a make-simens , bimetal overload relay with single phase protection10-16a with 1no+1nc contacts3ua5200-2a make-simens , auxilary contactors220v v dc coil 6a 2no+2nc 3th3022-0b make-simens , add on block 1 no(3tx4010) 2a for mounting on 3tf3 & c26th3 contacotr make-simens3tx4010- 2a , add on block 1nc(3tx4001) 2a for mounting on 3tf3 & c26th3 contacotr make-simens3tx4010- 2a , power contactor 22amp 3ph supply-240v ac22amp 3ph contac supply-240v ac3tf3300-0a make-simens , aux contactor220v dc 9amp 7watt 4 no 3tf3010-0b , mccb 3 pole 500 amp 415 v ac make c&s model abe 803
 Loading, Please wait...

Connect us via What's Up