Get complete information related to latest Analysis Service Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Analysis Service Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Analysis Service Tenders.
Tender For tender for supply of hdpe sand bag of size 15inch x 30inch under job no 2215 mta , cement opc 43 grade packed in hdpe bag each 50 kg wt conforming to is 8112 - 1989 make-birla gold , ambuja , ultratech , acc , jk , dalmia , cgi sheet 10feetx3feet make-sail , tata , jindal , cgi sheet 8feet x 3feet make-sail , tata , jindal , cgi sheet 12feet x 3feet make-sail , tata , jindal , ppgi roofing sheet 10feet x 3feet long and thickness 0.63 mm with grard film as per store list , hdpe cover tarpaulin 30feetx30feet long make-standard , hdpe cover 20feetx15feet long make-standard , synthetic paint enamelled white confirming to is 5-2004 make-berger , asian , nerolac , synthetic paint enamelled black confirming to is 5-2004 make-berger , asian , nerolac , ms squire pipe 2inch x 2inch isi marked , electric geyser 5 star of capacity 25 ltr make-v-guard , racold , bajaj , crompton , pvc insulated sheathed heavy duty armoured electric cable with aluminium conductor 16 sqmm 4 core as per store list , plywood 4feet x 8feet x 12mm termite resistant and bwr cofirming to is 1328-1996 make-supreme , assam , green ply , kit ply , isi mark , mcb single pole 32 amp capacity b series confirming to is 8828 of 1996 make-havells , l and t , standard , led tube light fittings 15 w box type 4 feets with crca body pre coated white and prewired for led tube complete make-havells , bajaj , philips , crompton , exhaust fan 230 volts 300 mm sweep plastic body alongwith louvers and complete fittings make- bajaj , havells , crompton , synthetic paint enamelled og confirming to is 5-2004 make-berger , asian , nerolac , synthetic paint enamelled red confirming to is 5-2004 make-berger , asian , nerolac , plywood 4feet x 8feet x 6mm termite resistant and bwr confirming to is 1328-1996 make-supreme , assam , green ply , kit ply , isi mark , mattress 6feetx3feet x12mm make-kurlon , sleepwell , corform , hdpe water proof cover 15feetx15feet , make-shalimar , ro repair job no 3980 and 3662 , cable pvc insulated electric cables heavy duty 1100 volts grade multi stranded copper conductor of size 1.5 sqmm single core as per store list , led bulk head fitting high pressure die cast aluminum front cover with glass cover with specially design gasket with led lamp 10 watts as per store list , led street light 40w make-havells , bajaj , phillips , crompton , synthetic paint enamelled yellow confirming is 5-2004 make-berger , asian , nerolac , door hinges 75mm isi marked , aldrop complete set make-standard , tower bolt 6inch , make-anjali , brass chromium plated shower rose 100 mm dia with bend make-ess ess , prayag , johnson suisse , looking mirror of selected quality frameless of size 600x450x5mm make-prayag , saint gobian , modigaurd , switch piano 5 amp 230 volts flush type one way snow white make-anchor , ssk , cona , plug top 5 amp , make-anchor , ssk , cona , plug top 15 amp , make-anchor , ssk , cona , mcb spn 240 volts 32 amps make-havells , l and t , standard , wire flexible multi strand copper conductor multi stranded 0.0023 , 76 make-havells , finolex , paragon , mcb sp 6 to 32 amps make-havells , l and t , standard , exhaust fan heavy duty metal frame of 230 v for 450 mm sweep make-bajaj , crompton , usha , door size 3.0x2.10m double leaf ms sheet for door 2mm thick frame 9chowkat made of steel equal angle iron 55x55x6mm as per store list , supply , installing , testing and commissioning of heavy duty industrial grade dehumidifier 0.2 ton 15 lpd single phase 230 volt , fire extinguisher of one kilogram capacity , dry power type conforming to is-13849 along with its accessories , pvc switch board snow white size 8inch x 10inch for main switches , db make-supreme , polycab , finolex , service cable pvc insulated aluminium conductor , 1100 volt grade heavy duty 10 sqmm 2 core as per store list , non skid ceramic tiles of size 300mmx300mm on the floor. minimum thickness shall be between 6-8 mm tiles as per store list , synthetic paint enamelled brown confirming to is 5-
Tender For supply of supply of super structure over hard standing of size 30mx10mx5m as per tech specification and drawing att. , cement 43 grade opc packed in hdpe bag each 50 kg wt , hardcore 63 to 90mm , coarse sand free from vegetation , coarse aggregate 20mm graded , coarse aggregate 40mm graded , mild steel bars of size 6 to 8mm dia , mild steel bars of size 12 mm and above dia , mild steel bars of size 16 mm and above dia , ms binding wire , wooden planks for shuttering iind class wood of size 3.0 x 0.30 x 0.026m , nails various sizes , bricks sub class b , painting brush 4 inch , red oxside paint , synthetic enamel paint , cement opc 43 grade packed in hdpe bag each 50 kg wt , 80 mm thick coloured interlocking precast paver block i shape , distribution box 8 way , mcb spn 240 volts 32 amps , mcb sp 6 to 32 amps , pvc tape 19mm wide 5 m long , cable pvc insulated electric cable 1.5 sqmm single core , cable pvc insulated electric cable 2.5 sqmm single core , pvc casing capping 1 inch , pvc casing capping 3 by 4 inch , switch piano 5 amp 230 volts flush type one way , led tube light fittings 15w 230v box type 4 feet , screw full thread 6 x 19 mm , steel screw full thread with rawl , pvc switch board 7 inch by 4 inch , pvc switch board 8 inch by 10 inch , pvc l and t bend , switch socket combination 2 in 1 15 amp 230 volts , switch socket combination 5 amp 230 volts , service bracket 40mm dia gi tubing medium grade 1.5 mtr long , service cable pvc insulated aluminium conductor 10 sqmm 2 core , ceiling rose three terminal , led bulk head fitting high pressure die cast , pvc flexible wire copper conductor multi stranded , pvc flexible conduit pipe 15 mm dia , pvc round block , earthing plate 600 x 600 x 6 mm , ci earth pit cover of size 300 x 300 x 6 mm , funnel fitted with 20 mm diameter gi pipe 1.5 m long. , gi wire 4 mm diameter for earthing. , charcoal , salt normal , air terminal single pointed aluminium rod 12mm dia and 300mm long. , testing point terminal block make of gun metal , aluminium strips 25x3mm. , galvanised iron strip 32x6mm. , funnel fitted with 20mm dia gi pipe 1.5m lon , earthing plate 600x600x6mm gi steel , ci earth pit cover of size 300x300x6mm , insulating pvc block 75x75x30mm , hammer 1 kg with wooden handle , measuring tape 30mtr , crow bar 1.5 inch dia 4 feet long , hammer 1 by 2 kg with handle , hand gloves rubber isi marked , empty drum plastic 200 ltr , hand gloves leather best quality isi marked , gum boot , safety helmet , brick line 30 mtr , traveler brick mason , iron plaster , sprit level , wooden plaster , showel gs mk ii , kassi with handle , axes felling 3 kg , pan morter
Tender For custom bid for services - comprehensive annual maintenance contract of cs12 eakon cold store located at doddanekundi plant acd for a period of 3 years -summary: comprehensive annual maintenance contract includes maintenance, repair/replacement of all the components of the cold stores as follows: a) compressor, condenser unit, evaporator unit, suitable refrigerant, power supply system, control system, all safety features, operator panel, different type of sensors, interconnecting piping including drainage water pipes, cold room panels, coil and drain heaters, doors, lighting, temperature recording panels, and all other electrical, mechanical as well as electronics components of the systems & eurotherm electronic recorder.b) detailed scope of work:1 vendor should take over the cold stores for camc, in as-is-conditions., 2) preventive maintenance (pm) of the units to be carried out every month in consultation with user / maintenance dept, and detailed pm schedule to be drawn up and a copy of the pm carried out (service report) should be forwarded to purchase department duly endorsed by maintenance dept. for the reference and records. this pm should be carried out apart from periodical servicing and attending the breakdown calls. 3) servicing of the units should be carried out once in every three months, within two weeks of commencement of the quarter. this should be carried out preferably on sundays/ holidays. this servicing involves cleaning of condensers, cooling coils, filters (if any) leakage testing & rectification; and any/all other works required to ensure proper functioning of the units. a copy of the service carried out (service report) should be forwarded to purchase dept. duly endorsed by user/ maintenance dept for the reference and records. 4) the firm should monitor the temperature/ attend breakdown / preventive maintenance or any other request from user/ maintenance /quality dept. & monitor the functioning of all the cold stores. the firm should monitor and record the cold store chamber temperature every hour during shift hours and should take signature on recorded values by user, quality dept /maintenance dept. daily. the camc vendor s scope of work will be active for three shifts per day/round the clock, including sundays & holidays, i.e. all days throughout the camc period. 5) the firm should inform all the three departments user/qa/maint. in the event of malfunctioning of the equipment is noticed. they also should ensure safety of the materials stored in the event of failure of the cold stores. 6) the firm should report any abnormality, breakdown, or any bypass made immediately to all the three dept viz user, maintenance and quality dept. the equipment uptime should be greater than 95% without any interruption. 7) the firm should inform to the maintenance department in the case power failure, so that maintenance dept. can arrange for switching on the dg supply. 8) the firm should able to read the temperature in the electronic temperature recorder. 9) the firm should attend any number of breakdown complaints as and when reported by user/ maintenance dept/ quality dept during the contract period. the breakdown complaints should be attended within 8 hrs from the receipt of oral or written complaints and the system should be rectified within a day, except for the major breakdowns. 10) the firm should bring all the tools and tackles necessary including consumables for the repair / servicing. 11) the firm should hand over the cold stores in good working condition after the completion of camc, failing which necessary remedial actions will be taken to recover loses to acd-hal by deducting equivalent amount from the due amount. c) monthly checks: checking and servicing of cold stores.- (a) compressors- condensing units, solenoid valves and all gauges, drier, globe valves and all gauges, hp/lp switches, oil pressure switches ., expansion valve and mixture., refrigerant level and top-up if required., oil le