Get complete information related to latest Anesthetic Item Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Anesthetic Item Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Anesthetic Item Tenders.
Tender For corrigendum : supply of drugs/surgical items etc. as a local purchase for the patients falling under the scheme of ayushman bharat-pradhan mantri jan arogya yojana (ab-pmjay/sehat) and other schemes operative in skims. - item specifications, group 1 drugs (all general drugs, generic drugs, pharma cpse drugs etc.) consisting of tablets, capsules, ointments, syrup, drops, injectables, patches, lotion, other formulation and nutritional supplements, excluding group 2 and 3 drugs., group 2 all anti-cancer drugs (consisting of tablets, capsules, syrup, injectables and any other formulation)., group 3 all imported and patented drugs., group 4 all surgical items (consisting of diagnostic surgical items, implants, stents, therapeutic surgical items, super speciality surgical items, interventional surgical items, suture, dressing material, disposable surgical instruments etc. including patented items) excluding imported surgical items., group 5 all imported surgical items (consisting of diagnostic surgical items, implants, stents, therapeutic surgical items, super speciality surgical items, interventional surgical items, suture, dressing material, disposable surgical instruments etc. including imported patented surgical items).
Tender For supply of veternary medicines surgical items anti rabies vaccine and animal food for treatment of stray animals and annimal birth control program at pashu ashray sthal aasra bhopal for the year 2024 25
Tender For providing of facility management services - lumpsum based - healthcare; supply of veterinary healthcare medicines injections surgical items vitanins and feed supplements; consumables to be provided by service provider (inclusive in contract cost)
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical and suture items(rate contract for the period ending on 31.12.2026)
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical and suture items - anti a blood grouping serum ip(anti a monoclonal serum) [225], anti b blood grouping serum ip(anti b mono clonal serum) [226], anti d(rh) blood grouping serum ip/anti d blood grouping serum ip [227], vdrl antigen (with +ve and -ve control) / rpr slide kit :- specification for rpr _rapid plasma regain) slide test for detection of regain antibodies in syphilis1. rapid plasma reagin test kit having non- treponemal cardiolipin antigen coated carbon particles used in the detection of regain antibodies in serum / plasma of suspected cases of syphilis by the flocculation reaction.2. the kit should be meant for qualitative and semi quantitative detection of regain antiboidies against the non-treponemal cardiolipin antigen.3. sensitivity & specificity should be 95% or more.4. positive & negative control serum should be provided with the kit for at least 10% of the tests in each kit.5. the kit should have shelf life of minimum 12 months or more at the time of delivery of consignment. the kit should be stored at 2 c - 8 c.6. adequate literature detailing the principle, components, methodologies, validity criteria. bio-safety, performance characteristics, storage conditions, limitation of assay, manufacture and expiry dates and methods of disposal should be provided with each kit.7. the test should be free from possible interferences with potentially cross reactive sera.8. all the test kits should be provided with necessary / required disposable accessories in sufficient quantity.9. the imported kit should have approval of the statutory authority in its country of origin . the imported kits should have been registered and licensed in india by the cdsco. (central drugs standard control organization), double blood bags with sagm (350ml)general specifications annexure- xvi and specification in annexure-xxiii, laproscopic knotless pga -pcl bidirectional taper point surgical suture self fixation device with autolock mechanism made up of pga -pcl bidirectional taper point 17 mm & 32cm, curved cutter stapler 40 mm linear cutter simultaneous cutting and stapling, aortic punch 4.5 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, aortic punch 3.6 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue,conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, biopsy gun with compatible co-axial needle 14g x 11cm to 20cm programmable automatic should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved., programmable automatic biopsy gun with compatible co-axial needle size 18gx11cm or above should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved. (size 18gx11cm or above), programmable automatic biopsy gun with compatible co-axial needle size 18gx15cm or above should have 20mm sample notch and thin wall cannula for larger core and