Web Analytics Made Easy - StatCounter

Angle Frame Tenders

Get complete information related to latest Angle Frame Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Angle Frame Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Angle Frame Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :43180507 Due date: 09 Jan, 202609 Jan, 2026 NA
Tender For bid to ras tender for supply of mobile solar set 5 kva : :--72 cell ware solar panel 550 watt with power tolerance of 0pt5w maximum system voltage of 1500 and voltage at maximum power at 36pt70vmp the solar panel is made up of poly crystalline silicon with 72 solar cell per module that would be of 1 pt 5 mtr x 2 pt 00 mtr encapsulated with ethylene vinyl acetate make luminous waree utl , solar inverter 5 kva 120v with power conditioning unit integrate that consist of grid charger inverter and mppt solar charger the 5kva 120v solar inverter used solar and grid to charge the batteries since the usage of power from the grid is secondary grid power is only used when solar energy is not present make utl luminous , lead acid tubular batteries with the capacity of 150ah with normal voltage of 12v per battery make exide amaron utl luminous , 2 core 6 sqmm wire required to give connection from solar panels to batteries and for the electrical fitting purpose make havells anchor bajaj , rack for batteries ms iron angle frame size of 65cm x 65cm x 210cm , change over 100 amp make havells anchor bajaj , mcb 63 amp make havells anchor bajaj , trolley mobile solar set will be fixed on heavy duty steel trolley with 2 lockable wheels tyre should be size of 7 pt 50 to 16 14 ply rating and load capacity of 2 pt 50 ton trolley to have parking and over run break pulley tow hook and leaf spring four set 1 nos axles super structure of the trolley should be made of 150m x 75mm x 5mm thick u channel angle iron of size 75mm x 75mm and top platform 4mm thick ms plate necessary arrangement for fixing of 5 kva solar system with 01 nos tool box lockable battery compartment solar panel fold dimensions folded size 4 mtr l x 2 pt 10 mtr w x 0 pt 75 mtr h unfolded size 6 mtr l x 4 pt 5 mtr w mobility features four wheels with specify type pneumatic solid easy to tow or transport deployment process manual unfolding of solar panels instant electricity output from sunlight

CTN :43369467 Due date: 12 Jan, 202612 Jan, 2026 NA
Tender For corrigendum : supply of gabian box e e - gabion unit basket mesh type 10x12 size 1x1x1 as per specification given in atc , gabion unit basket mesh type 10x12 size 1 point 5x1x1 with separator as per specification given in atc , gabion unit basket mesh type 10x12 size 1 point 5x1x2 with separator as per specification given in atc , gabion basket size 2x1x1 mtr as per specification given in atc , shuttering plate size 1x1 mtr with ms sheet 3 point 15 mm thick welded on angle frame of size 1x 1 mtr size of angle 50x50x5mm as per specification given in atc , shuttering plate size 1x 0 point 50 mtr with ms sheet 3 point 15 mm thick welded on angle frame of size 1 x 1 mtr size of angle 50x50x5mm as per specification given in atc , ms pipe 48 point 3 mm dia 6 mtr long for shuttering as per specification given in atc , right angle coupler for jointer ms pipe 48 point 3 mm dia clapping the ms pipe as per specification given in atc , swiwel coupler as per specification given in atc , binding wire 22 swg black as per specification given in atc , plywood waterproof 8 feet x4 feet x12 mm

Central Government/Public Sector

CTN :42904317 Due date: 12 Jan, 202612 Jan, 2026 3.62 Crore
Tender For corrigendum : replacement of em items against ber held with ge i rnd east bangalore - supply, installation, testing & commissioning of double skin horizontal air handling unit of fully capacity, complete with double skin insulated with cfc free foam (puf) panels of 25mm thick, 42 kg/cum density. sandwitched between 0.6 mm thick g.i. sheets. outer skin shall be pre coated g.i. sheet pre coated off white. ahu frame works shall be of pre cast vertical and horizontal extruded aluminium profile with three way corner frame sections. frame construction should bear the load of structure and load of the frame structure shall be uniformly distributed along the entire housing of the ahu. food grade self adhesive coated neoprene gasket to be provided between panels and structure of the ahu to ensure the entire housing is airtight., backward curved blower to be supplied along with motor (kruger/nicotra). filter will be of 10 mic as pre filter, 3 mic as fine filter. cfm as below with 60-80mm sp complete all as specified and directed., note: rate quoted to be deemed to include civil works for hvac like breaking and opening for entry and exit of supply ducts from ahu room, exhaust ducts into shafts for exiting copper pipes / drain pipes also. fire rated material of 25mm thick phenotherm to be used near civil closures for fire resistant properties., a) 13200 cfm, 60mm static ahu capacity 33 tr., 11 tr dx outdoor ac unit complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a minimum capacity.note: rate quoted to be deemed to erection of condenser unit platform (ms angle frame with 02 coats of red-oxide and 01 coat of enamel black paint) with ms works for duct support., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 22 tr ducted packaged ac unit with 8800cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 11 tr ducted packaged ac unit with 4400cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 8.5 tr ducted packaged ac unit with 3500cfm complete all as specified and directed., supply, installation, testing & commissioning of air cooled ducted split air conditioners of capacity 8.5 tr with r2 series: r 407c eco friendly refrigerant, nominal cooling capacity 1,02,000 btu/hr, nominal air flow 3400 cfm, microprocessor based with lcd display controller and hermetically sealed scroll type compressor, all necessary connections with suitable size of copper cables and initial gas charging, provision of necessary pcc platform / iron angle frame for outdoor unit complete all as specified and directed by engineer-in-charge., dismantling / taking down / transporting carefully old acs outdoor & indoor unit with all connected acessories and to be deposited in mes store complete all as specified and directed., dismantling / taking down / transporting carefully old unserviceable ducting items off any size and capacity with all connected accessories and to

CTN :43400677 Due date: 12 Jan, 202612 Jan, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - onboard in submarines at naval dockyard, mumbai; price agreement for refurbishment of deck plates, supporting angle frames and guard rails in machinery compartment onboa..

CTN :43343712 Due date: 16 Jan, 202616 Jan, 2026 NA
Tender For supply of gabion unit basket mesh type 10x12 size 1x1x1 as per specification given in atc , gabion unit basket mesh type 10x12 size 1 point 5x1x1 with separator as per specification given in atc , gabion unit basket mesh type 10x12 size 1 point 5x1x2 with separator as per specification given in atc , gabion basket size 2x1x1 mtr as per specification given in atc , shuttering plate size 1x1 mtr with ms sheet 3 point 15 mm thick welded on angle frame of size 1x 1 mtr size of angle 50x50x5mm as per specification given in atc , shuttering plate size 1x 0 point 50 mtr with ms sheet 3 point 15 mm thick welded on angle frame of size 1 x 1 mtr size of angle 50x50x5mm as per specification given in atc , ms pipe 48 point 3 mm dia 6 mtr long for shuttering as per specification given in atc , right angle coupler for jointer ms pipe 48 point 3 mm dia clapping the ms pipe as per specification given in atc , swiwel coupler as per specification given in atc , binding wire 22 swg black as per specification given in atc , plywood waterproof 8 feet x4 feet x12 mm

Central Government/Public Sector

CTN :43306328 Due date: 13 Jan, 202613 Jan, 2026 NA
Tender For tender for supply of sitc of air conditioner : : -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1391 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters auto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply. the indoor unit shall be suspended from the ceiling using threaded rods- including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required. , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealedscrollrotary compressor and eco friendly refrigerantinitial charge of refrigerantcondensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply. the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floorlaying and interconnection of standard-length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required. necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no. 1 2 , supply laying of 4c x 2.5 sqmm frls pvc insulated 1.1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1.2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required. , supply and fixing of 75mm dia minimum 1.8mm thickness pvc covering pipe using necessary bend collor clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25x25x5mm l angle frame including clamps bolts nuts vibrating dampers as required for mounting of outdoor unit. , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar to match for the surrounding as required after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling.
 Loading, Please wait...

Connect us via What's Up