Get complete information related to latest Apfc Panel Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Apfc Panel Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Apfc Panel Scrap Tenders.
Tender For supply, errection, testing and commissioning of hvls fan with controller and extension cable to controller of 50 m length fan size 08 ft. dia no of blade 06 nos, air volume 95000 cfm power consumpti on 0.40 kw motor torque 80 nm speed 110 rpm maximum (variable from 0 to 90) noise< 40 db in put po wer single phase 230 volt 50 hz, weight 40 kg, motor type direct driven pmsm type outer rotor type magen ts grade n45sh insulation class h control penal mounting wall mounting 4-5 ft. from floor level vfd enclos ure ip 54 power coated steel cabnet compatibility bms compatibility 16, safety certification complete to ce required, make austar,bharat brayan or similar reputed make [ warranty period: 30 months after the da te of delivery ]
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous
Tender For supply of 5 h.p 3phase v4- borewell submersible pumpset - 100mm / ktp4143 /25 stage / 5h p / 3 phase /2880 rpm 380-415 volts. head : 7 to 130 mtr lpm : 180 to 60 pipe size : 40 mm moc : standar d, with electronic indoor control panel features of control panel. single phase preventor, phase reversal pr otection, unbalanced voltage protection, over load protection, dry run protection, rotor lock, cable open t rip, voltage /amp display, level controller by float , including non return valve, erection clamp preferred m ake: kirloskar, ksb, deccan, cri,texmo, crompton,havells,mbh,kbl,v-guard or equivalent. [ warranty period: 30 months after the date of delivery ]
Tender For supply of micro motor hand piece for med eqpt , micro motor assy for med eqpt , micro motor controller for med eqpt , armlet complete set for med eqpt , rotor hand piece for med eqpt , bull nose fitting for med eqpt