Web Analytics Made Easy - StatCounter

Array Tenders

Get complete information related to latest Array Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Array Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Array Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :36196667 Due date: 16 Jun, 202416 Jun, 2024 NA
Tender For these equipment are used for photocatalytic hydrogen generation. the generated hydrogen will be used in hydrogen fuel cells. the equipment required are 1 source meter 2 solar simulator with 1 - uv source 200 nm to 400 nm with power supply and 2 uv intensity meter 3- 4 probe resistivity station with constant current source with computer interface

Central Government/Public Sector

CTN :36197961 Due date: 28 Jun, 202428 Jun, 2024 NA
Tender For supply of genotyping methylation profiling array system

corporations/Associations/Others

CTN :36200296 Due date: 23 May, 202423 May, 2024 NA
Tender For sopply of materials and labour work for cctv project at technopark,trivandrum. - supply of materials and labour work for cctv project at technopark,trivandrum, supply part, supply of isi marked 25mm pvc conduits (medium) (ivory ) with suitable bend, coupling, saddle, screws ,flexible hose etc (all accessories under the scope of supplier)., supply of isi marked 20mm pvc conduit(medium) with suitable bend, coupling, saddle, screws ,flexible hose etc (all accessories under the scope of supplier)., supply of isi marked 25mm /32 mmhdpe conduit (medium) with suitable bend, coupling, saddle, screws ,flexible hose etc (all accessories under the scope of supplier)., supply of camera clamp on pole, supply of pole mounted clamp for ptz camera, supply of rj 45 connector, supply of 4f ofc, supply of gi pole 3 inch 5mtr/6 mtr class b --tata/ jindal/kalinga - annexure, supply of gi pole 4 inch 5mtr/6 mtr class b --tata/ jindal/kalinga - annexure, supply of 3" 2.5 mtr gi pole class b --tata/ jindal/kalinga - annexure, supply of 2" 4 mtr gi pole class b --tata/ jindal/kalinga - annexure, supply of outdoor flexible hoses, supply of sintex box (large), 12 core patch panel, outdoor patch box, supply of 3 modular pvc box with plate(make-legrand/crabtree,geco),(all accessories under the scope of supplier), supply of 6a switch(make-legrand/crabtree,geco),(all accessories under the scope of supplier)., supply of 6a socket(make-legrand/crabtree,geco),(all accessories under the scope of supplier)., supply of 16a /6a plug top(make-legrand/crabtree,geco),(all accessories under the scope of supplier)., supply of 6a mcb(make-legrand/crabtree,geco),(all accessories under the scope of supplier)., supply of 10a/16a mcb(make-legrand/crabtree,geco),(all accessories under the scope of supplier)., supply of 4/6 way db(make-legrand/crabtree,geco),(all accessories under the scope of supplier)., supply of 2 pole 40a isolator(make-legrand/crabtree,geco),(all accessories under the scope of supplier), labour part, fixing, termination and focusing of camera on wall/pole and neat installation of camera termination (using nut & bolt or fishers and screws under the scope of supplier) as per the standards and customer requirements., fixing, termination and focusing of ptz camera on wall/pole and neat installation of camera termination (using nut & bolt or fishers and screws under the scope of supplier) as per the standards and customer requirements., laying of pvc through wall & pulling of multiple cables( 3*2.5 sqmm power cable & 3x 1.5sqmm power cable & cat 6 cable& ofc etc) as required by the site condition through the pvc , neat dressing and termination of these cables using std. accessories like legs,glands,screws etc ( accessories under the scope of supplier) in all locations as per the standards and site requirements as pwd electrical standards, slab lifting for cable pulling through existing duct, fixing and neat installation of 4u equipment rack (using accessories under the scope of supplier) as per the standards and site requirements., fixing and neat installation of 6u equipment rack (using accessories under the scope of supplier) as per the standards and site requirements., fixing and neat installation of 9u ,19" outdoor metal rack fixing on pole, fixing and neat installation of server, fixing & neat installation of gi pole 3 inch 5mtr/6 mtr (75 mtr depth,50 cm conical structure,two coat primer,one coat aluminium foil paint and 25 mm metal bend & fabrication work), fixing & neat installation of gi pole 4 inch 5mtr/6 mtr (75 mtr depth,50 cm conical structure,two coat primer, one coat aluminium foil paint and 25 mm metal bend & fabrication work), fixing & neat installation of 3" 2.5 mtr gi pole, fixing & neat installation of 2" 4 mtr gi pole class b --tata/ jindal/kalinga - annexure, neat installation of network switch on rack on rack, fixing of 3 modular pvc box with plate(make-legrand/crabtree,geco),(all accessorie

corporations/Associations/Others

CTN :35999007 Due date: 24 May, 202424 May, 2024 15.47 Lacs
Tender For corrigendum : rate contract for repairing, testing, recalibration and tunning of different defective electronics cards/modules and imported c&i equipment of analog control system, a.t.r.s., aux. p.r.d.s., h.p. bypass, dynaspede feeder control , analog control system power supply, instrumentation, annunciation power supply, annunciation system, sadc system and flame scanner of all the three units of 3x210mw, a tps, anpara

CTN :36204976 Due date: 17 Jun, 202417 Jun, 2024 36.00 Lacs
Tender For supply of solar plant installation -hybrid inverters at location one , vrla gel batteries at location one , photovoltaic modules at location one , acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire at location one , galvanised mounting structure at location one , copper earth plate 600 mm x 600 mm x 3 mm at location one , copper strip at location one , lightening conductor at location one , 5 mm copper strip at location one , hybrid inverters at location two , vrla gel batteries at location two , photovoltaic modules at location two , acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire at location two , galvanised mounting structure at location two , copper earth plate 600 mm x 600 mm x 3 mm at location two , copper strip at location two , lightening conductor at location two , 5 mm copper strip at location two , hybrid inverters at location three , vrla gel batteries at location three , photovoltaic modules at location three , acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire at location three , galvanised mounting structure at location three , copper earth plate 600 mm x 600 mm x 3 mm at location3 , copper strip at location three , lightening conductor at location three , 5 mm copper strip at location three , hybrid inverters at location four , vrla gel batteries at location four , photovoltaic modules at location four , acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire at location4 , galvanised mounting structure at location four , copper earth plate 600 mm x 600 mm x 3 mm at location four , copper strip at location4 , lightening conductor at location four , 5 mm copper strip at location four , hybrid inverters at location five , vrla gel batteries at location five , photovoltaic modules at location five , acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire at location five , galvanised mounting structure at location five , copper earth plate 600 mm x 600 mm x 3 mm at location five , copper strip at location five , lightening conductor at location five , 5 mm copper strip at location five , hybrid inverters at location six , vrla gel batteries at location six , photovoltaic modules at location six , acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire at location six , galvanised mounting structure at location six , copper earth plate 600 mm x 600 mm x 3 mm at location six , copper strip at location six , lightening conductor at location six , 5 mm copper strip at location six

CTN :36140378 Due date: 21 May, 202421 May, 2024 1.90 Lacs
Tender For corrigendum : providing of tentage service lumpsum based - passing out parade; tent rentals, floorings, power supply, furniture & equipment rentals, plastic chair

CTN :36195494 Due date: 13 Jun, 202413 Jun, 2024 62.50 Lacs
Tender For supply of solar plant installation - supply & installation testing and commission of hybrid inverters designed for 48volt 5kw for capacity off grid solar power plants including transportation upto site , supply fixing testing and commissioning of vrla gel batteries 2 volt 48 volt 300 ah exide racily amaraja hbl with necessary fixtures for 5kw solar power plant upto site , supply fixing testing and commissioning of photovoltaic modules mono crystalline mono perk 550 watt as per mnre specification with necessary fixing arrangements nut bolts junction box etc for 5 kw solar power plants off grid solar power plants including transportation upto site , providing fixing testing and commissioning of acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire etc complete as per design parameters of mnre for 5 kw off grid solar power plants including transportation upto site , providing fixing galvanised mounting structure with fixing arrangements for pvms at each corner and centre on each side nut bolts clamps gi flats excavation for basis of structure cement concreting 1 2 4 cement 2 coarse sand 4 graded stone aggregate fixing complete as per directions of engineer in charge including transportation upto site , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing cement concrete masonry enclosure with cover plate having locking arrangement and watering pipe of two point seven meter long etc with charcoal coke and salt as required , supplying and laying 25 mm x 5 mm copper strip at zero point five metre below ground as strip each electrode including connection terminating with nut bolt spring washer etc as required joining shall be done by overlapping and with 2 sets of brass nut bolt and spring washer spaced at 50mm , providing and fixing of lightening conductor finial made of 25 mm dia 300 mm long g i tube having single prong at top with 85 mm dia 6 mm thick g i base , providing and fixing 25 mm x 5 mm copper strip of surface or in recess for connections et as required , supply & installation testing and commission of hybrid inverters designed for 120volt 10kva for capacity off grid solar power plants including transportation upto site , supply fixing testing and commissioning of vrla gel batteries 2 v cell 120 volt 300 ah exide racily amaraja hbl with necessary fixtures for 5kw solar power plant upto site , supply fixing testing and commissioning of photovoltaic modules mono crystalline mono perk 550 watt as per mnre specification with necessary fixing arrangements nut bolts junction box etc for 10kw kw solar power plants off grid solar power plants including transportation upto site , providing fixing testing and commissioning of acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire etc complete as per design parameters of mnre for 10 kw off grid solar power plants including transportation upto site , providing fixing galvanised mounting structure with fixing arrangements for pvms at each corner and centre on each side nut bolts clamps gi flats excavation for basis of structure cement concreting 1 2 4 cement 2 coarse sand 4 graded stone aggregate fixing complete as per directions of engineer in charge including transportation upto site , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing cement concrete masonry enclosure with cover plate having locking arrangement and watering pipe of two point seven meter long etc with charcoal coke and salt as required , supplying and laying 25 mm x 5 mm copper strip at zero point five metre below ground as strip each electrode including connection terminating with nut bolt spring washer etc as required joining shall be done by overlapping and with 2 sets of brass nut bolt and spring washer spaced at 50mm , providing and fixing of lightening conductor finial made of 25 mm dia 300 mm long g i tube having single prong at top with 85 mm dia 6 mm thick g i base ,

Central Government/Public Sector

CTN :36193298 Due date: 22 May, 202422 May, 2024 14.18 Lacs
Tender For annual maintenance contract of uninterrupted power supply equipment (ups) at aiims-jodhpur.

Central Government/Public Sector

CTN :36195327 Due date: 25 May, 202425 May, 2024 21.02 Lacs
Tender For providing of custom bid for services - 200133975 phased array ultrasonic inspection paut of boiler tube weld joints during boiler overhauling in fy 2024 2025 and 2025 2026 at ntpc tstps kaniha

Central Government And Public Sector

CTN :36091707 Due date: 22 May, 202422 May, 2024 17.01 Lacs
Tender For corrigendum : procurement of vc system at nerldc - vc codec , speaker tracking camera , microphone array , all-in-one amplifier and speaker , sitc of vc system
 Loading, Please wait...

Connect us via What's Up