Get complete information related to latest Array Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Array Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Array Tenders.
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou
Tender For corrigendum : supply installation commissioning and maintenance of new switches for existing networking infrastructure and line array column speaker ups at high court complexes at jammu and srinagar
Tender For corrigendum : supply of classroom av capture and amplification system : : - ceiling array microphone , dsp with dante and aec support , cat 6 network cable , network switch , installation integration and commissioning , testing and demonstration , training and documentation , comprehensive warranty support
Tender For bid to ras corrigendum : supply of audio video conference system - digital based flus mount chairman discussion unit with microphone on off button , digital based flus mount discussion unit with microphone on off button , digital conference controller , ceilling primium mount speakers with maximum power 20 w , wall mount speakers with maximum power 30w , ceiling array microphone , unidirectional gooseneck condenser microphone for podium with on off sliding switch , wireless handeled microphone with 32 preset channels , mixer amplifier with 240 watt , 4x4 matrix switcer for camera inpt 4 port hdmi and 4 k hdmi out , av controller with supports connection to various devices including pcs android devices ios devices tablets and mobile terminals with a gigabit ethernet port , ethernet switch 8port gigabit ethernet unmanaged poe switch , hd baset extender set can extend hdmi , 1x4 4k60 hd baset splitter 150m , video capture device , 4k video conference ptz camera , loop cable , led monitor lift with retractable screen with 15.6 , wired and wireless conference presentation switcher , 8 channel digital signal processor , supply of copper conductor rodent protected all required hdmi cable usb cable speaker cable av cable or connectors etc as per req , stp cable 1 roll 305 meters , installation and commissioning , 55 inch led tv55-inch diagonal , standard earthing with copper plate using standard size copper strip 25 x 3 mm from system in conference room to ground floor , comprehensive annual maintenance contract