Get complete information related to latest Auto Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Auto Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Auto Cable Tenders.
Tender For supply and fixing of 7.5hp 60 stages power bore well pump set , 63mm hdpe pipe, power cable, starter control panel board etc. at theen chaman, i.n nagar, malkajgiri under eam section, eam cell, o&m divn.no.xiii.
Tender For supply of control cable this item shall be use for suitable for green techpo india co2 weld ing machine [ warranty period: 12 months after the date of delivery ]
Tender For procurement of spares for prabhu make flp ht starter and drill panel - vaccum contactor 400a 3.3kv, part no.ht 200 , vaccum contactor rectifier bridge, part no.ht 201 , isolator 200a 3.3kv on off, part no.ht 100 , bottle for vaccum interrupture 400a part no. ht 202 , vaccum contactor clossing coil 110v dc, part no. ht 203 , vaccum contactor holding coil 110v dc, part no. ht 204 , aux switch for vaccum contactor 2no 2nc, part no. ht 205 , p.t. 40 va 0- 8-12v 0-110v, part no. ht 206 , aux contactor 3no 1nc 110v, part no. ht 208 , resin cast potential transformer 750va 3,3 kv 110v single phasepart no. ht 300 , resin cast potential transformer 300va 3,3 kv 110v 3phase, part no. ht 350 , h t control fuse 3.3 kv 2 a, part no. ht 400 , resin cast moulded cbct, part no. ht 500 , resin cast moulded c t for ol 3.3kv , part no. ht 600 , resin cast moulded c t for ammeter , part no. ht 650 , dmc moulded flp terminal complete 3.3kv 400a for ic, tg, og and partition, part no. ht 700a , static type idmtl over current and short circuit relay with time leg over load setting 50 percent to 200 percent and short circuit, part no. ht 900a , 72 sq mm ammeter supressed scale, part no. ht 1000 , 72 sq.mm voltmeter 0-5kv 110 volts, part no. ht 1100 , hrc fuse base and carrier for control, part no. ht 1200 , hrc fuse base link 4 a for control, part no. ht 1201 , lamp holder with lamp for starter, part no. ht 1400 , brass cable gland complete with ci clamp, part no. ht 1600 , pilot relay 12v dc, part no. ht 2200 , intrinsically safe pilot panel complete, part no. ht 3000 , transformer with rail without pane, part no. dp 5 001 , transformer panel fitted with 50a contactor and all other access. but wo transformer, part no. dp 5 001a , transformer panel fitted with 50a contactor com, pat no. dp 5 001e , 25a contactor with 110v coil, part no. dp 5 002a , 50a contactor with 110v coil, part no. dp 5 002b , thermal overload relay, part no. dp 5 003 , test reset micro switch, part no. dp 5 005 , earth leakege trip indication lamp holder, part no. dp 5 006 , earth leakage trip indication lamp, part no. dp 5 006a , glass fuse 1 amp, part no. dp 5 007a , glass fuse 2 amp, part no. dp 5 007b , on off toule switch, part no. dp 5 008 , pilot relay 12 dc 8 pin, part no. dp 5 015 , el relay 12 ac 8 pin, part no. dp 5 016
Tender For supply of 2.5 sqmm, 4 core unarmored flexible round copper cable for tight bending, motion control applicati on. voltage grade:1100v, conductor: class 5 annealed tinned copper insulation: epr insulated outer sheath c sp standard: is9968 pt1. (detailed specification attached) [ warranty period: 30 months after the date of delive ry ]
Tender For painting and repairing work of valve house, cable trench at switchyard, new dg building and switchyard control room at baira siul power station
Tender For supplying erection testing of fully automatic control panel board and providing and fixing of changeover switch 16 sqmm submersible cable at various twells in sector 11 panchkula
Tender For supply of solar plant installation -hybrid inverters at location one , vrla gel batteries at location one , photovoltaic modules at location one , acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire at location one , galvanised mounting structure at location one , copper earth plate 600 mm x 600 mm x 3 mm at location one , copper strip at location one , lightening conductor at location one , 5 mm copper strip at location one , hybrid inverters at location two , vrla gel batteries at location two , photovoltaic modules at location two , acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire at location two , galvanised mounting structure at location two , copper earth plate 600 mm x 600 mm x 3 mm at location two , copper strip at location two , lightening conductor at location two , 5 mm copper strip at location two , hybrid inverters at location three , vrla gel batteries at location three , photovoltaic modules at location three , acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire at location three , galvanised mounting structure at location three , copper earth plate 600 mm x 600 mm x 3 mm at location3 , copper strip at location three , lightening conductor at location three , 5 mm copper strip at location three , hybrid inverters at location four , vrla gel batteries at location four , photovoltaic modules at location four , acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire at location4 , galvanised mounting structure at location four , copper earth plate 600 mm x 600 mm x 3 mm at location four , copper strip at location4 , lightening conductor at location four , 5 mm copper strip at location four , hybrid inverters at location five , vrla gel batteries at location five , photovoltaic modules at location five , acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire at location five , galvanised mounting structure at location five , copper earth plate 600 mm x 600 mm x 3 mm at location five , copper strip at location five , lightening conductor at location five , 5 mm copper strip at location five , hybrid inverters at location six , vrla gel batteries at location six , photovoltaic modules at location six , acdb dcdb array control panels with mcbs mccbs fuses lugs copper cable wire at location six , galvanised mounting structure at location six , copper earth plate 600 mm x 600 mm x 3 mm at location six , copper strip at location six , lightening conductor at location six , 5 mm copper strip at location six