Get complete information related to latest Auto Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Auto Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Auto Meter Tenders.
Tender For procurment of medical oxygen item and services - medical oxygen items, medical grade max flow copper pipe-, 12 mm, 15 mm, 22 mm, 28 mm, 35 mm, 42 mm, 54 mm, copper fittings:-, reducing tee, 15x15x12, 22x22x12, 22x22x15, 28x28x15, 28x28x22, 35x35x15, 35x35x22, 35x35x28, 42x42x15, 42x42x22, 42x42x28, 42x42x35, 54x54x15, 54x54x22, 54x54x28, 54x54x35, 54x54x42, reducer, 15x12, 22x12, 22x15, 28x15, 28x22, 35x15, 35x22, 35x28, 42x15, 42x22, 42x28, 42x35, 54x15, 54x22, 54x28, 54x35, 54x42, reducing elbow, 15x12, 22x15, 28x22, copper fittings 12 mm, elbow, tee, capler, copper fittings 15 mm, elbow, tee, capler, copper fittings 22 mm, elbow, tee, capler, copper fittings 28 mm, elbow, tee, capler, copper fittings 35 mm, elbow, tee, capler, copper fittings 42 mm, elbow, tee, capler, copper fittings 54 mm, elbow, tee, capler, bed head panel and accessories:-, bed head panel (doublerail), vacuum slider(aluminium), s.s. basket, siring pool, i.v. hook, bhp monitor tray, switch for bhp 6 module electric plate with 5/15, wall mounted sliding monitor tray, wall mounted fixed monitor tray, patient monitor stand, o2 and n2o regulators:-, single stage single gauge mox regultor, single stage twin gauge mox regultor, two stage twin gauge mox regultor, single stage single gauge mno regultor, single stage twin gauge mno regultor, two stage twin gauge mno regultor, single stage twin gauge co2 regulator, o2 heavy duty high pressure regulator (2500lpm), iox-2000 regulator, adopter for iox-14 regulator, gauge for iox-14 regulator, iox-14 regulator, iox-14 regulator complete, o2 and n2o manifold:-, single cylinder manifold, 1+1 manifold, 2+2 manifold, tail pipe and manifold n.r.v:-, flexible tail pipe- o2 and n2o, manifold n.r.v. o2, flowmeter and humidifier bottle:-, b.p.c. flow meter without humidifier bottle, humidifier bottle for b.p.c. & fa valve, adapter pipeline bpc flow meter, o2 and n2o control panels:-, semi automatic control panel, fully automatic control panel- analog, fully automatic control panel- digital, fully automatic control panel-3 source digital, medical gas outlet point & probe:-, medical gas outlet, parkodex type gas outlet, b.s. type gaso utlet, probe for medical gas outlet, s.s. valve and accessories:-, self sealing valve- o2, s.breaket, plastic button for s.s. valve, plastic cover for s.s.valve, pipeline adoptor l-type for s.s. valve [l.probe], y- connector, single pipeline adoptor s.k.p. for o2, n2o, air and vacuum, twin pipeline adoptor for s.s. valve, ward vacuum unit and theater suction:-, 600 ml jar with lide, 1000ml jar with lide, 2000 ml jar with lide, vacuum regulator, 600 mlward vacuum complete unit, 1000 mlward vacuum complete unit, 2000 mlward vacuum complete unit, theater suction trolly (normal), theater suction trolly (with valve &y-connector), theater suction unit(aluminium base), plastic sadel:-, 12 mm, 15 mm, 22 mm, 28 mm, 35 mm, 42 mm, 54 mm, zonal valve box:-, zonal ball box- 6 gas, zonal ball box- 5 gas, zonal ball box- 4 gas, zonal ball box- 3 gas, zonal ball box- 2 gas, isolation valve with 3pcs. fitting:-, 12 mm, 15 mm, 22 mm, 28 mm, 35 mm, 42 mm, 54 mm, medical gas alarm:-, single pipeline alarm without gauge, single pipeline alarm with gauge, 2 service pipeline alarm digital type, 2 service pipeline alarm analogue type, 3 service pipeline alarm digital type, 3 service pipeline alarm analogue type, 4 service pipeline alarm digital type, 4 service pipeline alarm analogue type, 5 service pipeline alarm digital type, 5 service pipeline alarm analogue type, 6 service pipeline alarm digital type, pressure gauge:-, 4" pressure gauge- 0-14 kg, 4" vacuum pressure gauge-0- 16 kg, pressure gauge o2- 50 mm 0-250kg, pressure gauge o2- 50 mm 0-16 kg, pressure gauge n2o-50 mm 0-250kg, pressure gauge n2o-50mm0-16kg, vacuum pressue gauge-50 mm 0-760 mmhg, teplon washers, sheet and service kit:-, 12 mm teplon washer, 15 mm teplon washer, 22 mm teplon washer, 28 mm teplon washer, 35 mm teplon washer, 42 mm teplon
Tender For corrigendum : purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-a
Tender For corrigendum : supply, installation of equipments and other items to the pediatrics department of mims mandya - mims-pediatrics-neonatal ventilator with humidifier, mims-pediatrics-hfnc, mims-pediatrics-pulseoxymeter, mims-pediatrics-neonatal electronics weighing machine, mims-pediatrics-nebulizer heavy duty, mims-pediatrics-laminar flow, mims-pediatrics-servo control therapeutic hypothermia, mims-pediatrics-radiant warmer, mims-pediatrics-led phototherapy, mims-pediatrics-computerized pft, mims-pediatrics-portable autoclave machine, mims-pediatrics-oxygen flow meter with jar, mims-pediatrics-portable electrical suction apparatus , mims-pediatrics-ups 60 kva , mims-pediatrics-furnitures