Get complete information related to latest Auto Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Auto Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Auto Switch Tenders.
Tender For corrigendum : supply, installation, testing and commissioning of 48v dc, kpm, 184 ah ni-cd battery set along with buyback at 400kv switch yard control room, ukai tps gsecl.(et-6001 emd-ii)
Tender For supply of 220kv out door yard materials to vhep, hosangadi-576282 - compressor belt, zinc coat spray, post insulator clamp, c clamp-moose to drake, c-clamp-drake-drake, four hole undrilled paddle, isolator fixed contact 245kv, auxiliary contactor cs3c-31e, auxiliary contactor cs3c-22e, local-remote selector switch, control switch trip/ close, motor power contactor, latching coil cv3-11, relay releco make c5a30, precision limit switch, rotary switch 32a, selector switch for eses, off push button switch-eses, open push button switch -eses, close push button switch -eses, power contactor lc1d09ud, four hole paddle-1200a, sprecher + schuh make add on block cs4-p11, sprecher+ schuh add on block cs3-p, sprecher+schuh contr.cs4c 31z, sprecher+schuh contr.cs4c 22z
Tender For corrigendum : supply of patternised switch and switch socket for yard 3037 to 3040 ngopv : : - 15 a, sw. skt 4 contact, triple pole_3037-3040 , t. p. 415v socket_3037-3040 , dp switch 6a fixed key_30373040 , dp switch 6a fixed key red colour_3037-3040 , dp switch 6a loose key_3037-3040 , door switch left hand side_3037-3040 , door switch right side_30373040 , dp switch socket 6a-16a 6 pins,048-8473_30373040 , dp sw. skt6-16a with cover and plug,0488489_3037-3040
Tender For work of cutting/clearing of jungle / wild bushes and grass of outside are/ inspection gallery of 400/220kv switch yard at 400 kv sub station, rishikesh
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t