Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi
Tender For corrigendum : supply of fire detection and alarm system powergrid silchar sub station : : - smoke detection system , fire detection and alarm system for control room , fire detection and alarm system for switchyard panel room of 9 m length , fire detection and alarm system for 400kv gis hall , fire protection system for local relay room for gis , indoor fire detection and alarm system for fire fighting pump
Tender For supply of fire alarm detection system - addressable fire alarm panel-02 loops with lcd , addressable smoke detector with base , addressable heat detector with base , addressable manual call point , addressable or conventional hooter cum strobe , addressable control modules , addressable input or output module , addressable input module , response indicator , addressable loop isolator , installation charges
Tender For supply of addressable type fire alarm system at in north paravur : : - sitc of addressable main fire alarm panel , sitc of repeater panel , sitc of addressable photo thermal detector , sitc of addressable manual call point , sitc of addressable horn cum strobe , sitc of fault isolator , sitc of addressable fire control module , sitc of response indicator , supply and laying of 2x1.5 sqmm fire alarm armoured cable , sitc of mcp signage , sitc of relay module
Tender For corrigendum : supply of supply, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm control panel with 2 loops modules , supply, installation, testing and commissioning of intelligent addressable multi criteria detector with a combination of optical and thermal including mounting base , supply, installation, testing and commissioning of intelligent addressable smoke detector including mounting base with led , supply, installation, testing and commissioning of addressable weather proof outdoor manual call point with ip rating of ip 67 , supply, installation, testing and commissioning of addressable loop powered stand alone sounder outdoor with inbuilt isolators , supply, installation, testing and commissioning of active repeater panel to be connected peer to peer with main fire alarm panel
Tender For corrigendum : supply of accessories/ consumables/ spares for air conditioners/ laundry equipment/ boiler equipment/ medical gas/ furnitures etc. - wheels for ventitator trolleys as per sjicr sample, hepa filters box type with flange 395 x 395 x 50 mm(forspecifications refer tech bid), hepa filters box type with flange 400 x400 x110 mm box flange type (forspecifications refer tech bid), hepa filters box type with flange 490 x 490 x 300 mm (forspecifications refer tech bid), hepa filters box type with flange 650 x 242 x 100 mm (for specifications refer tech bid), hepa filters box type with flange 650 x605 x100 mm-(refer tecbid forspecifications), nozzle for burner unit, mobrey level control magnetic rod (1.5ton capacity boiler) -1 set, max green 3399ph correction chemical- 1kg, main pressure gauge 3/4 inches siphon, leather hand glouse -1 pair, spirax float steam trap size 1 inches, softener plant with pump 200 ltrs, softener plant strainer, softener plant resin -1 bag (50 kg), softener plant resin -1 ltr, softener plant chemical-ab 270 -1 kg, salt for softener plant regeneration -50 kg, s.s vertical nrv for feed water pump, r o plant chemical wextret genesol 9002, r o plant chemical- lf-60 -1 kg, r o plant chemical genesol 703 1 kg, r o plant chemical genesol 38 1 kg, r o plant cartridge filter, pump mechanical seal size 35 mm, ph value finding meter, peso licence renewal of 15 kl 1 hsd tank class b (mysore) ( per year )., peso licence renewal of 15 kl 1 hsd tank class b & c (banglore)( per year )., peso licence renewal of 15 kg 1 hsd tank class b (kalburgi per year), panel board programmable feathertouch display -1 set, painting brush -2 nos, ss presure gauge with glycerin 21 kg/cm2, ss female adapter (63 mm size), ss 63mmx19mm short branch pipe (nozzle )newage make, single delivery ss hydrant valve (80 mm flange & 63 mm coupling) -newage make, rubber lined rrl fire hose with couplings 15 mtr length 63mm dia, pvc blank cap with chain(63 mm size), lip washer (63mm size), hose box key, fire hose box made with 18 gauge ms sheet with shutters , glass , key ,breathing & powder coating with stand, fbi gm couplings (fire brigade inlet )1, coupling washer (63mm size), butterfly valve 80 mm pn 16 - audco make, eighty mm pn16 butterfly valve with gi pipe,flange,nut bolt & washer audco make, eighty mm plate type nrv with gi pipe,flange,nut bolt & washer intervalve or crystal make, fifty mm pn 16 butterfly valve with gi pipe,flange,nut bolt & washer audco make, two hundred mm cl flange end foot valve with nut washer normax make, one hundred and fifty mm pn16 butterfly valve with gi pipe,flange,nut bolt & washer audco make, one hundred and fifty mm plate type nrv with gi pipe,flange,nut bolt & washer intervalve or crystal make, one hundred mm pn16 butterfly valve with gi pipe,flange,nut bolt & washer audco make, one hundred mm cl flange end foot valve normal make, supply & installation, testing and commissioning of addressable two zone fire alarm control panel, supply & installation, testing and commissioning of addressable sounder with accessories, supply & installation, testing and commissioning of addressable break glass manual call point, supply & installation, testing and commissioning of addressable smoke sensor base for mounting, supply & installation, testing and commissioning of addressable isolators loop isolation module, volt meter 440volt for pump house spair parts and frabrications- 3 phase pannal boare and starter for 10hp , 20hp , 30hp , 50 hp, skf bearing - 6313 for 50 hp 1440 rpm induction motor, skf bearing - 6312 for 30 / 40 hp 1440 rpm induction motor, skf bearing - 6310 for 20 hp 1440 rpm induction motor, skf bearing - 6210 for 50 hp 1440 rpm induction motor, wall mounted fan 400 mm sweep., supplying & installation testing and wiring for 2.5sqmm fire alarm cable & using pvc conduit pipe 19mm dia 2mm thick with suitable size bends, junction box adhesive pas
Tender For corrigendum : supply of deliverables as per table-5 for fire alarm and control panel system as per edt-2875or etb , supply of deliverables as per table-6 for fire extinguishing system as per edt-2875 for etb at afs k , installation, testing and commissioning of fire alarm and control panel system for etb as per clause , installation, testing and commissioning of co2 based fire extinguishing system for test cell, fuel r