Tender For rc for call basis repairs and misc works of split ac in various bas of ec mumbai - attending complaint and wet servicing of ac unit upto 50 kms , attending complaint and wet servicing of ac unit upto 51 to 100 kms , attending complaint and wet servicing of ac unit above 101 kms , replacement of starting capacitor 80 to 100 mfd of ac unit , replacement of running capacitor 36 to 50 mfd of ac unit , replacement of capacitor for condenser fan 4 to 6 mfd of ac unit , replacement of sensor for split ac unit , replacement of contactor relay for split ac outdoor unit , replacement of starting relay of ac unit , replacement of thermostat of ac unit , replacement of selector switch of ac unit , replacement of blade for condensor of window or split ac unit , replacement of blower assembly for split ac unit without motor , replacement of pcb for conventional split ac indoor unit of 1.5 tr , replacement of pcb for outdoor unit of invertor type split ac , replacement of pcb for indoor unit of invertor type split ac , replacement of 1.5tr or 2tr split ac remote , replacement of fan motor for condenser unit of conventional 1.5 or 2 tr of ac , replacement of blower motor for indoor unit of 1.5tr or 2 tr of split ac , replacement of 20mm dia flexible pvc pipe for drain water connection of ac , charging of r22 or r32 or r134 or r410 refrigerant gas upto the optimum working pressure suitable for 1.5 or 2tr ac alongwith attending leakage , replacement of cond coil manufactured with cu tube and al fins with antirust coating and blue fin hydrophilic coating for sac incl. credit of old coil , dismantling of window ac unit alongwith casing ms supporting frame , dismantling of split or high sensible ac incl. id and od unit aw all acc. pump down of gas and keeping all dismantled material at safe location , transportation of dismantled 2 no. ac units upto 20 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units upto 20 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 2 no. ac units from 21 km to 50 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 21 km to 50 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 2 no. ac units from 51 km to 100 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 51 km to 100 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 100 km upto 200 km with all accessories incl. hiring of vehicle, manpower etc , itc of 1.5 or 2tr window ac unit with properly finshing and minor civil work , itc of wall mounting type 1.5 or 2tr split ac unit with properly finishing and minor civil work , itc of 2x1.5 tr high sensible ac unit with properly finishing and minor civil work , s and f of 1 by 4 inch copper refrigeration pipe , s and f of 3 by 8 inch copper refrigeration pipe , s and f of 1 by 2 inch copper refrigeration pipe , s and f of 5 by 8 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 1 by 4 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 3 by 8 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 1 by 2 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 5 by 8 inch copper refrigeration pipe , s and f of prefabricated powder coated heavy duty iron stand having projection arm minimum 600 mm , s and fabrication of m.s. frame made out of various m.s. sections incl. hardwares finishing, painting, minor civil work etc , p and f of 12mm thick prelaminated particle board with decorative lamination on both side flat pressed 3 layer or graded wood particle board , s and l of 4 x 1.5 sq mm copper conductor unarmoured cable of 1.1
Tender For rc for call basis repairs and misc works of split ac in various bas of ec nagpur - attending complaint and wet servicing of ac unit upto 50 kms , attending complaint and wet servicing of ac unit upto 51 to 100 kms , attending complaint and wet servicing of ac unit above 101 kms , replacement of starting capacitor 80 to 100 mfd of ac unit , replacement of running capacitor 36 to 50 mfd of ac unit , replacement of capacitor for condenser fan 4 to 6 mfd of ac unit , replacement of sensor for split ac unit , replacement of contactor relay for split ac outdoor unit , replacement of starting relay of ac unit , replacement of thermostat of ac unit , replacement of selector switch of ac unit , replacement of blade for condensor of window or split ac unit , replacement of blower assembly for split ac unit without motor , replacement of pcb for conventional split ac indoor unit of 1.5 tr , replacement of pcb for outdoor unit of invertor type split ac , replacement of pcb for indoor unit of invertor type split ac , replacement of 1.5tr or 2tr split ac remote , replacement of fan motor for condenser unit of conventional 1.5 or 2 tr of ac , replacement of blower motor for indoor unit of 1.5tr or 2 tr of split ac , replacement of 20mm dia flexible pvc pipe for drain water connection of ac , charging of r22 or r32 or r134 or r410 refrigerant gas upto the optimum working pressure suitable for 1.5 or 2tr ac alongwith attending leakage , replacement of cond coil manufactured with cu tube and al fins with antirust coating and blue fin hydrophilic coating for sac incl. credit of old coil , dismantling of window ac unit alongwith casing ms supporting frame , dismantling of split or high sensible ac incl. id and od unit aw all acc. pump down of gas and keeping all dismantled material at safe location , transportation of dismantled 2 no. ac units upto 20 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units upto 20 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 2 no. ac units from 21 km to 50 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 21 km to 50 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 2 no. ac units from 51 km to 100 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 51 km to 100 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 100 km upto 200 km with all accessories incl. hiring of vehicle, manpower etc , itc of 1.5 or 2tr window ac unit with properly finshing and minor civil work , itc of wall mounting type 1.5 or 2tr split ac unit with properly finishing and minor civil work , itc of 2x1.5 tr high sensible ac unit with properly finishing and minor civil work , s and f of 1 by 4 inch copper refrigeration pipe , s and f of 3 by 8 inch copper refrigeration pipe , s and f of 1 by 2 inch copper refrigeration pipe , s and f of 5 by 8 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 1 by 4 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 3 by 8 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 1 by 2 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 5 by 8 inch copper refrigeration pipe , s and f of prefabricated powder coated heavy duty iron stand having projection arm minimum 600 mm , s and fabrication of m.s. frame made out of various m.s. sections incl. hardwares finishing, painting, minor civil work etc , p and f of 12mm thick prelaminated particle board with decorative lamination on both side flat pressed 3 layer or graded wood particle board , s and l of 4 x 1.5 sq mm copper conductor unarmoured cable of 1.1
Tender For corrigendum : supply of b and d spares of integrated platform management system (ipms) for p17a ships - supply of following items, 4 pole relay + base, 2 pole relay, green transparent lens, engine speed gauge (72 x 72), fuel admission gauge (48 x 48), fresh water temperature gauge (48 x 48), main oil pressure gauge (48 x 48), pitch response gauge (72 x 72), shaft speed gauge (72 x 72), gg speed gauge (72 x 72), pt speed gauge (72 x 72), gt lo pressure gauge (48 x 48), exhaust temp gauge (48 x 48), rugged computer, rugged monitor, keyboard, trackball, gt tic gauge (72 x 72), 18 mm round iindicator, white lens, engine speed meter (72 x 72), lube oil pressure meter (48 x 48), firemain pressure. meter (48 x 48), salvage pressure. meter (48 x 48), signal splitter, vdmc cc, cca vdop-24, cca vdi-48, cca vai-48, cca vao-8, serial link adapter, xmc card, ehm data collector unit - 8 channel, ehm data collector unit - 4 channel, battery, proximity switch/sensor, inclinometer system, combined optical smoke and heat detector, is optical smoke/heat detector, heat detector (fixed 54 c + rate of rise, heat detector(fixed 84 c), addressable / conventional ir flame dete, manual call point ip67, electronic solenoid bell, pre-amplifier, bulkhead mounted display unit, oes pressure tx (-1 to +1 bar) is, oes pressure tx (0 to 5 bar) is, oes pressure tx (-1 to +2 bar), oes pressure tx (0 to 6 bar), oes pressure tx (0 to 8 bar), oes pressure tx (0 to 8 mbar) - citadel, chilled water system line temperature t, tri axis vibration accelerometer, single axis vibration accelerometer, tli ldu, sge-25 /exia - 5 mtrs cable; is type (0-, pce-28 /exia - 5 mtrs cable; is type (0-, sge-25 -5 mtrs cable; (0-300 mbar), pce-28 5 mtrs cable; (0-300 mbar), level switch, ball valve, main control panel, repeater panel, afas level switch - digital (non is), afas level switch - digital (is), afas pressure sensor (non is), afas pressure sensor (is), cctv digital ir camera, loop m x h, buscon m 10 h, buscon m 20 h, power supply card set 5v, power supply card set 12v, network switches, rectifier 60v/50a, battery charger 54v/8.5a, mcb 1 pole dc 80a/80v , mcb 2 pole dc 20a/80v, mcb 2 pole dc 80a/80v, mcb 3 pole dc 10a/480v ac, red led, green led, fan 120x120x25mm, spares set for eot, ir flame detector - intrinsically safe, spare intrinsically safe pick off coil, dc-dc converter - ups, red transperant, analog meter 48 x 48, 0-2000 knmx10, analog meter 48 x 48, 0-120 deg c, analog meter 72 x 72, 0-110 %, push button 2no, mom, push button 1no+1nc, alternate, lube oil pressure gauge (48 x 48), rugged touch monitor, afds repeater m 4.3, manual call point, siren, mcb 2 pole, 6 a, 2 pos selector switch, "lamp 24 vac/dc,, single led white diffuse ", speaker, fan, dc to dc convertor 48vdc, passive isolator, horn and strobe, terminal blocks, din rail mdl (50f) vai, terminal blocks, din rail mdl (50m) (vdo, mcb 2 pole, 20 a, ethernet switch, fiber optic module, fan assembly, 19in rack mount, butterfly valve -triple offset / nab / n, butterfly valve (fire safe) -triple offs, butterfly valve -triple offset / nab / n, butterfly valve (fire safe) -triple offs, top entry ball valve -straight / gun met, top entry ball valve -straight / gun met, top entry ball valve -straight / gun met, top entry ball valve -straight / gun met, top entry ball valve -straight / gun met, spare set : valve w/o actuator- bf/ tf/, spare set : actuator 150-200 nb- bf/ tf/, spare set : valve w/o actuator- bf/ tf/, spare set : actuator - bf/ tf/ fs ss a35, spare set : valve - bf/ tf 200 nb nab -, spare set : valve - bf/ tf 150 nb nab -, spare set : valve - bv /te /fb 65 nb gun, spare set : actuator - bv /te /fb 65 nb, spare set : valve - bv /te /fb 40 nb gun, spare set : actuator - bv /te /fb 40 nb, spare set : valve - bv /te /fb 25 nb gun, spare set : valve - bv /te /fb 20 nb gun, spare set : valve - bv /te /fb 10 nb gun, fuse tb, glass fuse, schottky diode, glass fuse 3 a, 3 pos selector switch, blade fuse 5 a, blade
Tender For supply of electrical - led tube lights, pvc wire, ceiling rose, day night sensor, switches, floating ball, gate ball, round sheet:, fan sheets, pvc batton, gang box, socket, switch, black screw, gutties, batton pins, tape roll, sheet