Tender For supply of poh kit for load sensing device for (sm&tm) consisting of 12 items (as per annexu re). [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sens
Tender For design,supply,installation and commissioning of automated and computerized test bench fo r automatic pressure monitoring(apm) device and load sensing device (lsd) as per specification in attach ed annexure-a [ warranty period: 30 months after the date of delivery ]
Tender For supply of poh kit for load sensing device of bobrn and blc wagons [escorts design] consisting of 7 items as under: [1] k-ring- 4kb4861/1- 02 no [2] k-ring- 4kb4861/2- 01 no [3] wire mesh filter- 4kb4708- 03 no [4] filter- 4a70275- 01 no [5] o-ring- 4a-43411- 01 no [6] sealing ring- 4a31340/11- 01 no [7] scraper 4a49352- 01rdso item id - 3100389010.
Tender For e-bid for rate contract cum supply and empanelment of surgical and suture items - dual rapid test kit for hiv & syphilis, synthetic absorbable wound closure device with dual cut barb with velded loop on end madeup with glycomer blue size 2-0, 1/2 circle, 24mm, 30-45cm rc size 2-0, linear cutter 55mm with six rows, 3d staple formation, option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only, linear cutter 75mm with six rows, 3d staple formation, option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only, universal linear cutter cartridge 75mm open linear cutter compatible with selectable staple height linear cutter 75mm.option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only. 6 rows 3-d staple technology., laparoscopic shears 5mm diameter,36cm long, 18mm curved coated blade and a clamp arm with tissue pad, capable of cutting,sealing,grasping and coagulating blood vessels up to and including 7mm in diameter, 360 degrees rotation, advance hemostasis hand activation mode for sealing vessels upto 7mm in diameter ,ergonomic handle compatible with ultrasonic energy source, capable of hand and foot activation with an integrated hand piece and transducer., aortic punch 4 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, rem (return electrode monitoring) single use, corded patient return electrodes conductive adhesive hydrogel with usfda, offset connector cardio sensor electrodes it should have high conductive wet gel to ensure reliable traces. it should be design with offset connector to prevent artefacts from disrupting the readouts it should have high quality ag/agcl sensor to ensure excellent trace quality it should have size not more than 72 x 68 mmsize adult, over-the-ear nasal cannula 50 tubingover-the-ear nasal cannula with star lumen, 50 tubing, must be flexible contoured lip tab provides a high level of stability and patient comfort. over-the-ear design for a comfortable and secure fit, crush- and kink-resistant tubing. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification., adult mask for tracheostomy adult mask for tracheostomy and laryngectomy aerosol therapy tubing connector must swivels 360 for ease of positioning; 22 mm od connector accepts 22 mm, corrugated tubing and nebulizer tees. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification., pardiatric mask for tracheostomy pediatric mask for tracheostomy and laryngectomy aerosol therapy tubing connector must swivels 360 for ease of positioning; 22 mm od connector accepts 22 mm, corrugated tubing and nebulizer tees. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification., adult conventional single water trap (non-heated) ventilator circuits are available in a variety of different configurations and styles.to incorporate standard connectors for use with a variety of ventilators, ported wyes allow pressure sensing and temperature monitoring and include tethered caps, all adult conventional circuits with 72 in. long, standard ventilator circuit with straight connector inspiratory limb water trap (for use with hmes only). manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification, adult ventilator circuit single water trap adult conventional single water trap (non-heated) ventilator circuits are available in a variety of different configurations and styles.to incorporate standard connectors for use with a variety of ventilators, ported wyes allow pressure sensing and temperature monitoring and include tethered caps, all adult conventional circuits with 72 i