Web Analytics Made Easy - StatCounter

Automatic Timer Switch Repair Tenders

Get complete information related to latest Automatic Timer Switch Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Automatic Timer Switch Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Automatic Timer Switch Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :39194516 Due date: 25 Feb, 202525 Feb, 2025 71
Tender For corrigendum : procurement of electrical items for neraluru gp for one year - led bulb 12wat, alluminum wire 2.5 sq, panel lock, led bulb 15w, led tubeight 20w, indicator lamps, led flood light 200w, led flood light 150w, outdoor enclosure heavy gauge, cfl bulb holders, contactor 200a, contractor 100amps, bakelite panel board, pipe clamp 2 inch od, pipe clamp 1 inch od, led street light 36 wattage, led street light 100 wattage, astronomical timer , contractor 50 amps, mcpcb 150w, mcpcb 50w, mcpcb 100w, led driver -1500ma 50w, electric tester, fuse cutouter 100amps, fuse cutouter 63amps, fuse cutouter 40amps, ip 65 out door led strip, cfl fitting 65w full set, cfl fitting 45w full set, safety glouse, safety shoes 7- 10 inches, cutting palyer, condenser 3way, condenser 2 way, bulb 250w sodium, sv chowk 250wattage, sodium light full set 250w, mcp - 63 amps 2p, mcp - 40 amps 2p, mcp - 32 amps 2p, mcp - 25 amps 2p, mcp - 16 amps 2p, pipe clamp 1.25 inch od, pipe clamps 1.5 inch od, led street light 50w, led street light 24w, led street light 150w, pingani cfl holder, gi wire 20 gauge, insulation tape , dp switch 32amps open type, copper cabel 10 sq mm, copper cabel 6 sq mm, copper cabel 4 sq mm, copper cabel 2.5 sq mm, copper cabel 1.5 sq mm, copper cabel 1 sq mm, bed switches 16a, alluminium 4sq cabel, alluminium 20sq cabel, alluminium 16sq cabel, alluminium 10sq cabel, led bulb 60w, led bulb 50watts, led bulb 40w, led bulb 30w, led bulb 23w, led bulb 18watts, alluminium 6sq cabel, led bulb 9w

Central Government And Public Sector

CTN :39075342 Due date: 20 Feb, 202520 Feb, 2025 11.05 Lacs
Tender For corrigendum : supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sens

Central Government/Public Sector

CTN :39145973 Due date: 20 Feb, 202520 Feb, 2025 NA
Tender For custom bid for services - comprehensive annual maintenance contract of cs12 eakon cold store located at doddanekundi plant acd for a period of 3 years -summary: comprehensive annual maintenance contract includes maintenance, repair/replacement of all the components of the cold stores as follows: a) compressor, condenser unit, evaporator unit, suitable refrigerant, power supply system, control system, all safety features, operator panel, different type of sensors, interconnecting piping including drainage water pipes, cold room panels, coil and drain heaters, doors, lighting, temperature recording panels, and all other electrical, mechanical as well as electronics components of the systems & eurotherm electronic recorder.b) detailed scope of work:1 vendor should take over the cold stores for camc, in as-is-conditions., 2) preventive maintenance (pm) of the units to be carried out every month in consultation with user / maintenance dept, and detailed pm schedule to be drawn up and a copy of the pm carried out (service report) should be forwarded to purchase department duly endorsed by maintenance dept. for the reference and records. this pm should be carried out apart from periodical servicing and attending the breakdown calls. 3) servicing of the units should be carried out once in every three months, within two weeks of commencement of the quarter. this should be carried out preferably on sundays/ holidays. this servicing involves cleaning of condensers, cooling coils, filters (if any) leakage testing & rectification; and any/all other works required to ensure proper functioning of the units. a copy of the service carried out (service report) should be forwarded to purchase dept. duly endorsed by user/ maintenance dept for the reference and records. 4) the firm should monitor the temperature/ attend breakdown / preventive maintenance or any other request from user/ maintenance /quality dept. & monitor the functioning of all the cold stores. the firm should monitor and record the cold store chamber temperature every hour during shift hours and should take signature on recorded values by user, quality dept /maintenance dept. daily. the camc vendor s scope of work will be active for three shifts per day/round the clock, including sundays & holidays, i.e. all days throughout the camc period. 5) the firm should inform all the three departments user/qa/maint. in the event of malfunctioning of the equipment is noticed. they also should ensure safety of the materials stored in the event of failure of the cold stores. 6) the firm should report any abnormality, breakdown, or any bypass made immediately to all the three dept viz user, maintenance and quality dept. the equipment uptime should be greater than 95% without any interruption. 7) the firm should inform to the maintenance department in the case power failure, so that maintenance dept. can arrange for switching on the dg supply. 8) the firm should able to read the temperature in the electronic temperature recorder. 9) the firm should attend any number of breakdown complaints as and when reported by user/ maintenance dept/ quality dept during the contract period. the breakdown complaints should be attended within 8 hrs from the receipt of oral or written complaints and the system should be rectified within a day, except for the major breakdowns. 10) the firm should bring all the tools and tackles necessary including consumables for the repair / servicing. 11) the firm should hand over the cold stores in good working condition after the completion of camc, failing which necessary remedial actions will be taken to recover loses to acd-hal by deducting equivalent amount from the due amount. c) monthly checks: checking and servicing of cold stores.- (a) compressors- condensing units, solenoid valves and all gauges, drier, globe valves and all gauges, hp/lp switches, oil pressure switches ., expansion valve and mixture., refrigerant level and top-up if required., oil le
 Loading, Please wait...

Connect us via What's Up