Tender For e-bid for rate contract cum supply and empanelment of surgical items - braided e caprolactonecoated lactomer 1, 90cm gs-25,37-40mm1/2 circle taper point, braided e caprolactone coated lactomer 2-0 90cm gs-25,3omm1/2 circletaper point, polypropylene blue monofilament, 2-0, 90 cm 1/2 circle round body double needle 26 mm, polypropylene blue monofilament usp3/0,2,90 cm,1/2 circle taper point (double armed),26 mm, polypropylene blue monofilament, 4-0, 75 cm 1/2 circle round body double needle 17 mm, hand activated curved taper tip coagulating shears compatible with ultrasonic cutting and coagulation device,9cm length,16mm curved active blade with adaptive tissue technology capable of sealing blood vessels up to and including 5mm in diameter, with ergonomic symmetrical finger ring grip-focus 9, hand activated curved taper tip coagulating shears compatible with ultrasonic cutting and coagulation device,17cm length,16mm curved active blade with adaptive tissue technology capable of sealing blood vessels upto and including 5mm in diameter, with ergonomic symmetrical finger ring grip - focus 17, synthetic oxidised re- generated cellulose double layered with peg and trilysine size 5*10cm or size 5-7 x 7-11 cm or size 4x 8 inch, double wall resuscitator with peep valve in paediatricsit should be fully autoclavable double wall with hand strapit should be supplied with autoclavable reservoir bag it should have a singleshutter valve system made of silicone rubberit should have easy attachment of peep valve for peadiatricit should have provision to attach manometer for paediatrics ambu bagbag volume: mark iv baby (300 ml)weight: baby (190 g)it should be us-fda, ce & iso certified, ultrasorbs ap disposable drypads,dry pad for moisture management, 58.4x90cm, with breathable layer, super absorbent core, aqua shield film and air permeable back sheet, absorbency of 1800- 2300gm, usfda/ce/biscompliant, iso13485 compliant, volumetric incentive spirometer (adult) volumetric incentive spirometer (adult) 4000 ml with handle. volume measurement must be compact comfortable designed to accommodate large inspired volumes. must have good-better-best flow window & advanced, low work-of-breathing design.particulate filter screen in device housing must help to reduce risk of foreign matter passing to patients.expandable and collapsible tube must help patients find comfortable position for treatments and can be removed when storing the device. ergonomic swiveled mouthpiece allows to patients create tight seal to enable more accurate measurement. flow indicator with smiley face provides visual target for desired inhalation and bright green flow indicator make it easy for patients to see results. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k &ce certification., neonatal high flow cannula having 8 litreflow. it can also be used for hfnc + nippv/cpap. should have a soft tip., pur-xro catheter 20 cm, 28g/1fr picc line with stylet, splitting needle with securing wings with 8cm extension tubing ( flow rate 0.7ml/min)., pur-xro catheter 30 cm, 24g/2fr picc line with split cannula and 10cm extension tubing over catheter (flow rate 4.5ml/min)., silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces), silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces), silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces), long term double lumen dialysis catheter with kit accessories should be provided ( catheter,pull apart sheath, dialator, tunneling stylet,guide wire j/s,with disppencer and injection caps, symmetrical tip retrograde and antigrade long term double lumen dialysis catheter size 15 fr x 23 cmusfda certification, absorbable
Tender For e-bid for rate contract cum supply and empanelment of surgical items - "sterile disposable perfusion set (infusion set) with airway and needle (paediatric use) burette type measured volume chamber of 100 ml drop size of approx 60 drops per ml injection port,latexfree, for intermittent medication. floating auto shut off valve (latex free) in burette. soft and kink resistant pvc tubing. roller controller for flow control tube length 150 cm 23g needle as per iso 8536-5", "sterile disposable (single use) teflon / ptfe i.v. cannula with integrated 3 way stop cock. size 20g should be packed in transparent, single blister pack. as per is 10555 standard", "sterile disposable (single use) teflon / ptfe i.v. cannula with integrated 3 way stop cock. size 22g should be packed in transparent, single blister pack. as per is 10555 standard", "sterile disposable (single use) teflon/ ptfe i.v. cannula without port. size 24g suitable for paediatric & neonatal use should be packed in transparent, single blister pack. as per is 10555 standard", "plaster of paris bandages 15cm x 2.7mts / roll testing parameter should befollowed as per bp standard", urine collecting bag, disposable 2000 ml transparent sheet kink resistant flexible tubing not less than 90 cm in length should have non-return valve top drainage outlet graduated bag moulded handle for easy handling, vaccum suction set, 2.5 meter length, suction handle with suction tube sterile, pyrogenic free, latex free, single use, vascular catheter 5fr/16g, double lumen length 50cm.usfda/four digit notified ce approved. should have two guide wire 45 cm & 80cm or more(logline iv.) peel-away sheath glide thru 5fr *10 cm, guide wire nitinol 80 cm, guide wire nitinol 45 cm, introducer needle 21 g *7 cm,syringe-10 ml luer-lock, skin protectant prep pad, second site adjustable hub, measuring tape,5 fr pressure injectable picc line with blue flex tip 50 cm, dressing statloock stabilization device , vascular catheter 5fr/16g, double lumen length 55cm.usfda/ four digit notified ce approved, should have two guide wire 45cm & 80cm or more (logline iv.) peel-away sheath glide thru 5fr *10 cm,guide wire nitinol 80 cm,guide wire nitinol 45 cm,introducer needle 21 g*7 cm, syringe-10 ml luer-lock, skin protectant prep pad, second site adjustable hub, measuring tape,5 fr pressure injectable picc line with blue flex tip 55cm, dressing statloock stabilization device (suture less), vascular catheter with metal guide wire,5fr triple lumen, size range 55cm or more (logline iv:)usfda/four digit notified ce approvedsyringe 12 ml, internal stylet, measuring tape, stat lock catheter stabilization device (suture less), introducer safety peripheral iv catheter 20g,micro introducer with vessel dilator, guide wire-50 cm nitinol, needle introducer 21 g, safety scalpel,end cap, "core biopsy instrument with compatible co-axial needle (automatic disposal ) should be bevel tip.should have adjustable penetration depth of 18mm and 25 mm with automatic and semi- automatic firing modes in single instrument/gun.should have fire ready indicator to reduce the risk of premature instrument firing.should have advanced echogenic technology for enhanced visibility in ultrasound.should be available with compatible coaxial needle in a single kit. instrument / gun size: 18 gauge, 16cm with coaxial needle size: 17gauge, total cannula length 12.9cm.", disposable bone marrow biopsy needleshould have ergonomic two- piece t-handle design.should have trocar tapered stylet point for easy coring of bone.should have triple crown cannula tip with 6 cutting cannula facets.should be available with marrow acquisition cradle with sample size verification marking.11gauge, 4 inch length", "absorbable surgical suture (synthetic)antibacterial coated sterilised needled suture (braided coated polyglactin/ polyglycolic acid violet) 1/2 circle ct round bodied40mm, gs needle, suture length 90 cm", bed side leucodepletion filters for blood transfusion (for 2 u
Tender For purchase of sports exercise physiology lab equipments - cardiopulmonary exercise testing system (including treadmill & cycle ergometer) (2 years warranty)(pac), portable telemetric metabolic analyzer for field and laboratory use.metabolic analyzer portable telemetric system for metabolic analysis should have the following specifications:designlatest generation, single body - weather and dust proof to suit our requirement of tough testing conditions. it should operate in standalone, holter and direct connection to pc modes.weight on subjectless than 1 kg including battery and ergonomically designed multi-size adjustable harnesstesting capabilitypulmonary gas exchange (vo2, vco2), vo2 max, sub-max vo2, thresholds (at, rcp), heartrate with hr belt, resting energy expenditure (ree, rmr), indirect calorimetry w/ face mask, substrates analysis (rq, %fat, %pro, %cho)analysis method breath by breathmotion sensorsinbuilt gps, altimeter, accelerometer (3d + 8g range), gyroscope (3d + 2000 o/s range) andmagnetometer/compass (3d + 1000 t range)wireless connectivitywireless data transmission: bluetooth 2.1 + edr class ii (range >900 meters line-of-sight)connectivityusb, audio, heart rate (aux), wireless device interface (bluetooth for integration with compatible optional peripherals like spo2, ecg etc.)data storagestorage: 512 mb flash > 2,000,000 breathsadditional: sd-hc card 32gb/fat32 - internal slot user accessibledisplay lcd: 3.5 lcd transflective colour - high visibility with led-backlit tfttouch-screen: resistive technology, that allows gloves and wet fingersanalysersoxygen: gfc 0-25% range, lifespan approximately 12 months (very easily user replaceable) response time 120 mscarbon-dioxide: digital ndir 0-10% range, response time 100 msbarometer: range -600 to +5500mflowmeter: bi-directional digital turbine ventilation range 0 to 300 l/min powerbattery: rechargeable li-ion smart battery w/ lcd charge status indicator. 2 packs backup battery: embedded to allow main battery replacement during testing without loss of datamain: 100-240v ac/dc adapter, for direct/main power supply and battery charging. essential accessories / consumablesthe system should be supplied with a compatible treadmill and ergo cycle as per specs below. list of standard items supplied and details of consumables including o2 sensor with their life span should be provided. a compatible laptop pc, colour deskjet printer, 3 litre calibration syringe & calibration gas mixture cylinder with regulator should be supplied with the systemquality assurancemust have european ce, us fda and iso certifications. treadmill running machine with user terminal (display & keyboard) stand- alone and remote control with cpet via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 300 kg (660 lbs) speed range: 0-25 km/h elevation: 0 to 28% reverse belt rotation motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v - belt, very quiet operation safety arch should be provided with harness of 5(five) different sizes (small to large) safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10 to +40 degrees c, humidity 30 to 70% display: touch screen display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs para control software for pc must have ce certificationergo cycle functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat adjustment easy to control and calibrate. can be co
Tender For supply of short turn indicator battery operated analogue as per following specification.(1) functions: i.c. based & no. danger of shock, damage to the coil or variation in readings due to fluctuation in line voltage. (2) standard testing range: coils up to about 100mm od with an id as small as 10mm. (3) special features : single shorted turn in a coil of 48 swg also shall be detected. (4) dial size: 95 x 45mm (approx.) (5) dimension : 200 x 130 x 60mm(approx.) (6) consumption : 0.06watt.
Tender For 8759 repair maint of external water supply system pump motor level indicator pipe line valve chambers cleaning of oht sump and other connected works in new chsc and other connected area under age em ii of ge south pune