Tender For provision of web based automation (monitoring & control) system with cloud based centralized web-portal for data monitoring and management (ir niyantrac) for lifts, escalators, substation, 30%-70% lighting, street lighting in dhanbad, gomoh under dhanbad division
Tender For corrigendum : providing of custom bid for services - attending failure server of substation automationsystem in 132kv substation at talaipalli coal mining project through oem ms ms ge td india ltd oem
Tender For providing of custom bid for services - engagement of sas engineer for routine maintainance iro biennial service contract for substation automationsystem sas of ge td make pertaining to 400kv switchyarddstpsdvcandal,custom bid for services - engagement of sas engineer for breakdown maintenanceiro biennial service contract for substation automationsystem sas of ge td make pertaining to 400kv switchyarddstpsdvcandal,custom bid for services - engagement of protection engineer for breakdown maintenance iro biennial service contract for substation automationsystem sas of ge td make pertaining to 400kv switchyarddstpsdvcandal
Tender For corrigendum : providing of custom bid for services - annual maintenance contract for sas sub station automationsystem on oemoes basis for 22013233kv ktps substation under gomdv dvc hazaribag for period of 730 days through custom bid of gem
Tender For corrigendum : construction of 220 160 mva and 132 kv 50 mva gss at hindore rajiasar distt sriganganagar in rajasthan including survey supply of all smaterials erection including civil works testing and commissioning turnkey project - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1250 a, 25 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 50/31.5/25 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automationsystem network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specification, lighting panel typ
Tender For corrigendum : construction of 220/132 kv, 1x160 mva and 132/33 kv, 1x40/50 mva gss at 220 kv gss kolayat (distt-bikaner) in rajasthan including survey, supply of all equipments/materials, erection (including civil works), testing and commissioning (turnkey ) - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1600 a, 31.5 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 40/50 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automationsystem network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specifica