Get complete information related to latest Autopsy Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Autopsy Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Autopsy Equipment Tenders.
Tender For tender for the supply and installation of medical equipments at gagag, koppal and chamrajnagar medical colleges - refraction chair unit , nd yag laser with abraham lens, perimeter automated , operation theatre table hydraulic type , operating microscope led light six step magnification opthal, electrically operated dental chair with unit, ultrasonic filter cleaning instruments cleaner, vacuum apparatus for delivery, ventilator, electric suction machine, electro cautery machine, audio visual relay equipment for conducting cme, multi channel patient monitors, ctg machine, labour theatre lights, patient warming device, bubble cpap, hfov neonatal ventilator, neonatal ventilator, camera installation for operating microscope , operating microscope with monitor, hypopharyngoscope, brain evoked response audiometry model b, ent console unit, high frequency low volume cautery machine, rigid endoscopes adult, hd camera with video recorder, table top temporal bone dissection microscope, operating microscope with video recording system 2 members, coblation surgery system plasma wands, high frequency low temperature radiofrequency cautery for ent, flexible fibreoptic laryngoscope, esophagoscopy set, micro ear surgery instruments, temporal bone dissection laboratory setup, ent operating microscope for ot, ent opd unit, optic albiometry with topography, oct, applanation tonometer , auto refractometer with keratometer , desflurane vaporizer, pediatric flexible fiber optic bronchoscope, o t light dual dome with camera ready, vac therapy negative pressure wound machine, surgcial helmet with charger, arthoscopic euipment set, intramedullary reaming system- femur, orthopedic plier cum wire cutter ss, hip and knee joint replacement instruments set, arthroscopy knee hand instruments, arthroscopy shoulder hand instruments, ao small fragment set, ao basic set major, orthopedic battery operated drill with straight and reciprocating saw set, over head projector, electrical bone cutting drilling reaming system, c arm, rtms repetitive transcranial magnetic stimulation, serum lithium analyser automatic , eeg machine 32 channel with monitor, transcutaneous bilirubinometer, t piece resucitator, single surface phototherapy unit, double surface phototherapy unit, o2 blender, cold storge unit , abg analyzers , fully automated biochemistry analyzer, binocular faculty microscope, biosaftey cabinet, autoclave machine vertical its equivalent sterica 75ltr, automated external defibrillator, portable suction apparatus, areterial blood gas analyzer, video laryngoscope, mammography conventional, usg high end, dr flourscopy, laser for pigment removal with stand, laser for scar reduction with stand, laser for hair removal with stand, multi stainer work station, hematology slide stainer, penta head microscope with high end optics with hdmi multioutput photographic camera including software, cryostat freezing microtome for frozen section, embedding station, rotary microtome semi automated, cystoscope, co oximeter for continous hb monitoring, radio frequency ablation machine, washer extractor 60 kg, washer extractor slucing machine 30 kg, micro gel incubator, vein visualizer, ice lined refrigerator, cbc analyzer 6 part, phlebatomy chairs portable, blood bank refrigerator 600 litre, deep freezer 80, walk in cold freezer room, apheresis unit , cbc haematology analyser - 3 part , turnkey works for cssd and to be quoted by high pressure steam sterilizer bidder, flash autoclave 15 ltrs, low temperature, instruments washer disinfector with dryer, biopolar cutery machine orthopedic, bmd machine, autopsy work station, water double distillation plant, fully automated urine chemistry and sediment analyzer, thin layer chromatography wuth chromatography chamber , spectrophotometer double beem uv vis, centrifuges, flexible biopsy forcep 5fr, stent removal forcep 4fr, adapter for cystoscope, sheath for cystoscope, terimo guide wire, dj stent 4fr 24cm, stone basket 3fr and 4fr, ultra hd,
Tender For proposals for the planning, supply, installation, testing, commissioning, and training of a high-precision cranial robotic system with deep brain stimulation (dbs) capabilities at iisc, bangalore
Tender For technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system should have fda ap