Get complete information related to latest Axes Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Axes Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Axes Tenders.
Tender For bid to ras supply of fd electrification solar hybrid - supply and installation and testing of fd elect 5 kva solar hybrid plant of capacity 2 kw wind turbines and 3 kw solar modular along with all standard accessories for bidang , supply and installation and testing of 10kva solar hybrid power plant , solar street light 20 w or higher wattage , seven meter hdg pole , lightening conductor and earthing , cement opc grade 43 , pcc hollow block , coarse sand , stone aggregate crushed stone 20mm graded , stone aggregate crushed stone 40mm graded , tape measuring fiber 30 mtr long , tape measuring metallic 5 mtr long , electric hand drill machine , working goggle , hand gloves rubber , hand gloves leather , pan motor , phawrah with handle , shovel with handle , axes picks , crow bar , gum boot rubber , spirit level , plumbob steel , hammer , hdpe tarpaulin , steel bucket , mason trowe 125mm , mason trowel 150 mm , open jaw double ended spanner set , clay hammer 800 gms , brick hammer 1250 gms , plier side cutting taparia , solar panel , battery vrla , wind turbine , generator set 15 kva , copper earthing set , copper lightning arrester , fire extinguisher 2 kg , plastic dividing strip 3 mm thick , hardcore not exceeding 63mm , wiremesh , trowels as per isi mark , plumb bob steel , nylon mason thread 100 mtr long , measuring tape 05 mtr , measuring tape 30 mtr , drilling machine , tool kit for electrician
Tender For supply of 8 ton hydraulic jack with handle,bushing,jet puller assy,flap,oil cooler assy,repair kit msp 362 hand control valve,priming pump hand,rubber hose,rubber hose water pump to t connector,centre bolt,de spanner 516 38 bsf,tube extension 1-14 od x 10 bg thick 1,assy fog lamp frontyellow lens lh,assy fog lamp frontyellow lens rh,assembly door lock rh,tommy bar with square drive head for ope,pole screw,de spanner 1516x34 bsf,handle axes pick head 2 kg,bulb turn signal 12v21w,wrench for lifting spare wheel assy,assy wiper blade,bulb head lamp 208v 60x40,assy rear view mirror outside lh luma,assy rear view mirror outside rh luma,grease gun,tin rectangular 5 ltrs,de spanner 19x22,tyre inflating hose with nipple 5.70m lo,philips head screw driver 100 mm long ti,eng screw driver 1.2x8x150,first aid kit,tool bag for wheel wrench,warning lamp 4 4 low,tool bag,elementprimary,bolt steel m-24x1.5x80mm long lh,ring spanner 10 11 metric,inserter remover tube valve die,chisel 2810-0199,screw driver 12 300mm,de spanner 18 19,buck
Tender For supply of general store and clothing : : - handle axes pick head straight 915mm , open two sided spanner 21 x 23 , de spanner 24 x 26 metric , chaugal universal mk-2 , axes pick head 2 kgs , funnel fuel garage pattern , brushes flat paint 25mm tapered nylon , brushes paints and varnishes flat 50mm
Tender For corrigendum : purchase of biomechanical lab - force platedimensions (w x d x h) in mm : 600 x 400 x up to 50 number of axes for force measurement: all 3 axes. x,y,z plate should be portable in naturesensor type: piezoelectricsampling frequency-(hz) =1000 hz or more force measured on each axis-fx,fy: 2,000 newton or more, fz: 10,000 newton or more hysteresis- (%fso): 0.5 linearity (%fso) 0.5 crosstalk (%) : 2water resistance rating: ip 50 or better.should be inclusive of installation.should be supplied with carrying case for 2 plates and noise free ups for on-ground assessment. the carrying case should be strong and sturdy.should be able to accommodate portable force plate 9286 ba, daq box 5695 and connecting cablesshould be able to protect the equipment from rain, impact and dust, should have rollers to move easilyshould be able to accommodate an ups also., isokinetic dynamometershould be able to access/test various joints in isolation should be able to meet requirements to test sports personsshould be able to test in different resistance modes such as isokinetic (concentric-concentric, concentric-eccentric ,eccentric, concentric ,and eccentric-eccentric), isotonic, isometric, and passive protocols should include options for angles, hold-times, rest period, repetitions, and sets. the system should be able to test all the major body segments and joints such as shoulder, forearm, elbow, wrist, hip, knee, and ankle.should have adjustable range of motion stops in full 360 degrees.should have 360-degree rotation for the force arm (connecting dynamometer to the pedal) to have wide range of motionshould be able to accommodate different athletes with varying height and weight with provision for seatbelt harness for better stabilitythe dynamometer or chair should be movable to accommodate different athletes for quick set-up and better usability with locking clamps for securing the system in place for testingshould be able to do gravity correction when the limbs are positioned with the lever arm on the dynamometerthe software should be provided to analyze the raw data and export the raw and processed data in different file formats such as excel, text, etc. the software should provide detailed report for various testing protocols such as individual test for joints, data/graph overlay for comparing pre and post testing, repeatability, progress, multi-session.should be provided with latest compatible workstation/laptop of reputed brand like hp, dell (latest generation) processor, minimum16gb ram, windows os 11, and laser printerconcentric speed: 500 deg/sec or more eccentric speed: 500 deg/sec or more concentric torque: 500 ft-lb (678nm) or more eccentric torque: 500 ft-lb (678 nm) or more isometric torque: 500 ft-lb (678 nm) or more isotonic torque: 500 ft-lb (678 nm) or more isotonic torque as low as .5 ft-lbfeedback formats: roadway, interactive line, interactive path, reaction training, proprioception training, breakout, and pong.torques. time, torques. angle, torque bars, work bars, power bars. it should be possible to use mechanical stops even with custom patterns (important for safety in research)the same attachment should be usable for left and right side of subject for consistencies in data.should be certified and approved by ce/eu medical devices directives or usfda, nord boardit should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless conne
Tender For corrigendum : in-situ machine tools (ism) for machining rubber line sub merged sub assembly ss1 hardware segment-, linear axes, milling spindle