Get complete information related to latest Axial Fan Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Axial Fan Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Axial Fan Repair Tenders.
Tender For corrigendum : providing of custom bid for services - supply fabrication and installation of new plenum duct after removal of existing damaged plenum duct of ventilation system installed at blower room
Tender For various wqms activity 2024-25 (water quality monitoring survey). supply of laboratory equipement and chemical etc. and all other works contingent thereto. - bact. incubator:- nsw, ambassdor, optics technology, impact size 18x24x18.precise sterilization, incubating and drying in one unit. better mineral/ glass wool blanker insulation keeps the surface of the instrument from being burnt.silent hot air blower unique design of air circulation for uniform air movement. unique design of ventilation keeps the surface of the instruments from veing burnt. polish 304 grade s. steel interior corrosion resistant long life operation having adjustable shelves to make more space for different height. kanthal a-1, super quality coil shaped heaters duly embedded / wounded on the sides and bottom for better accuracy . full feature with touch screen controller temperature controller. a. hmi display with feather screen touch digital temperature controller b. continuous display of temperature, time, day and date door open alarm c. password protected operations. d. data transfer port: usb port technical specification:- temperature range : ambient to 70 c temperature stability : 0.5 c control panel : with mains and load indicator, mcb alarm , material : gi/ms with powder coated, inner : stainless steel 304, digital setting : 0.1 c digital resolution : 0.1 c safety function : temp. over shoot high and low temp. alarm 5 d c , mcb provided insulation: mineral wool front door : mineral wool insulated door with glass window. hardware:- lock and handle material zinc, base finish: spc, handle finish: black pc b3with key. hinges material zinc, pin material : ss 304 grade, finish stpc, opening angle : 180 deg power consumption: 220/230v ac supply 10% hz duty cycle : continuous, air conditioner 1.5 ton split, autoclave:- nsw,ambassdor, impact digital cap:- 78 liters heater:- 04kw size:- 400x600mm outer ss sheet chamber inner s.s. 304 unique desingn of radial locking for minimum steam loss, assure accurate steam generation / sterilization. s. steel 304 grade argon welded cylindrical inner tank / vessel having s. steel tabular immersion heater for steam generation. lid is made of thick mild steel plain lined with s. steel sheet for double protection optional : all s. steel thick lined lid/ s.s. ring 304 grade (all outer s. s. outer body-304 grade steel on customer request). fitted with painted mild steel ring and radial locking duly chrome plated. paddle lifting device is also provided. lid is having built in safety valve, release valve pressure gauge, water level / indicator. supplied with s. steel cylindrical basket. pressure range is adjustable from 05 to 20 psi 3 psi or better inner and outer wall both made of stainless steel. gasket is made from imported silicon rubber. fitted with microprocessor based fully automatic fuzzy logic control system with timer buzzer (auto time control). the unit is also fitted with low-water level cut-off as a standard feature. fitted with automatic purging and exhaust valve, beakers 1000ml (borosil), bottle brush, brown paper sheet, colour standard (100ml), cotton (500gm), dessicator (big size), borosil, durum tubes (100 in each pkt.), evaparating dish (12 nos) make borosil 3180072 evaporating, flat bottom with pour out dish ( approx o.d x height : 80x45 mm), macconkey broth (hi-media) 500gm, refrigrator temperature 0 to 20 c vertical shelves, atleast 6-shelves for storage of sample, inbuilt temperature controller, castor wheels for easy mobility, heavy duty wheels, toughend glass refrigrator with temp controll visi cooler with temperature indicator with nabl calibration 550 litres manual defrost system complete fridge dimensions - 64.00 x 72.00 x 205.00 cms reciprocating compressor 12 months warranty storage, silica gel grannules , 500 gm qualigens, spactula (steel), test tube basket, test tube stands (alumimium), test tubes (15x150mm), test tubes (18x150mm), turbidity standard (100ml)
Tender For various defects on electrical defects - various defects on electrical equipment., l-1355: anchor capstan hand sliding contact not working. defect to be rectified and proven for satisfactory operation., l-1356: msb-2 pms display unit not working due to defective ethernet switch. defect to be rectified and proven for satisfactory operation., l-1357: laundry washing machine not heating. suspect heating element defective. defect to be rectified and proven for satisfactory operation., l-1358: wardroom microwave not working. suspect control circuit and magnetron malfunctioning. defect to be rectified and proven for satisfactory operation., l-1359: battery charger-1 is showing ac fail alarm. suspect control card malfunction. defect to be rectified and proven for satisfactory operation., l-1360: one ventilation motor at fer showing low insulation. defect to be rectified and proven for satisfactory operation., l-1361: port bulwark not working and transformer output not showing. defect to be rectified and proven for satisfactory operation., l-1362: deck washing machine not working. defect to be rectified and proven for satisfactory operation., l-1363: hydrophore pump showing overload alarm view motor showing low insulation. defect to be rectified and proven for satisfactory operation., l-1364: co s pantry kent ro not working. defect to be rectified and proven for satisfactory operation., l-1365: exhaust fan of galley blower making abnormal noise. defect to be rectified and proven for satisfactory operation.
Tender For supply of various items for the dhr project entitled molecular biology applications research and diagnostic techniques - laboratory items, pc based true double beam uv-visible spectrophotometerspecification:1. optical system: czerny-turner mounting, single monochromator, double- beam system, 1,300 lines/mm, 240 nm blazed holographic grating 2. light source: deuterium lamp and tungsten-halogen lamp 3. detector: r-928 photomultiplier tube 4. wavelength range: 185 to 900 nm or higher 5. wavelength accuracy: 0.1 nm (656.1 nm) 6. wavelength repeatability: 0.05 nm 7. spectral bandwidth: 0.1, 0.2, 0.5, 1, 2, 5 nm in steps 8. resolution: 0.1 nm 9. stray light: max. 0.005 %t (220 nm nai) 10. mode: abs, %t, %r, 11. photometric range: -5 to 5 abs12. noise level: 0.00003 abs rms (500 nm) 13. wavelength slew rate: 14000 nm/min 14. wavelength scan rate: 4000 to 0.5 nm/min 15. below items must be supplied along with the main instrument:a) one pair of cuvettes, 10 mm path length, 3.5 ml volumeb) integrating sphere attachmentwavelength range: 220 nm to 850 nm or betteri) samples like powder, solid, colloidal sample, thin film etc are measured by using thisaccessoryii) minimum inner diameter of integrating sphere: 60 mmc) branded i5 pc with original os- 1 no, class ii, type a2 bio-safety cabinetspecification: 1. the bio-safety cabinets should be 4 feet width with front window must be a 10 sash opening and steel with smart coat interior 2. the bio safety cabinet must include dc motors. 3. the motor must automatically adjust the airflow speed without the use of a damper to ensure continuous safe working conditions, even without maintenance adjustments. 4. cabinet must use a pressure sensor (rather than anemometer) to detect pressure drop across the supply filter, rather than in just one point across the down flow. 5. the cabinet should display the inflow and down flow air velocities and must incorporate an led indicator, visual & audible alarm to indicate excessive hepa filters loading, blower failure, airflow speed failure, incorrect window position. 6. the front of the cabinet must be angled 10 to help minimize glare. 7. the cabinet noise level must be less than 65 db(a) for a 4-foot cabinet. 8. cabinet with lights on and fan at operating speed should consume less than 400 watts or less 9. the cabinet must automatically reduce fan/blower motor speed to 30% when the front window sash is in closed position to ensure reduced energy consumption when the cabinet is not is use. 10. uv light must be programmable to allow for specific exposure times from 0 to 24 hours. 11. the cabinet should have provision to fit taps for vacuum, water and non-combustible gas. 12. the bio safety cabinet should be nsf certified with listing on nsf website. 13. the bio safety cabinet should incorporate hepa filter of the class h 14 en 1822 or better and having minimum efficiency of 99.995% at 0.3 m particle size. 14. ventilation system exhaust and inflow air volume approx 300-350 cfm 15. audible and visual alarms for hepa filter failure, blower failure, airflow speed failure, incorrect window position. 16. the cabinet should be provided with fixed / adjustable height stand, uv light and one set of detachable arms rest and one / two electrical outlet. 17. the drain pan of the bsc should be made of stainless steel. the drain pan should not be painted, or power coated. 18. cabinet should be ce certified and declaration of moc should be provided. 19. port provision for clean and safe routing for vacuum tubing and cables throughthe side of the bsc for improved organization and work efficiency., vacuum ovenspecification: 1.volume(l): 60-802.temperature range ( c): rt+5-2503.temperature resolution ( c): 0.1(at 100 c)4.temperature variation ( c): (at100 c)5.heating power (w): 21006.vaccum range 0 ~ 1 atm7.timer: 1min ~ 99hr59min8.vaccum connector (mm): 109.venting connector (mm): 1010.inner size (mm): 400x400x40011.dimension (mm): 625x585x710, constant temperature incubators
Tender For supply of circuit breaker scavenger blower mr, cab ventilation and crew fan (pos no 56.1.69.6 1.69.71 type- 5) as per clw spec no clw/es/3/0096 (alt-l) and abb document no hbtb585552r101 3. [ warranty period: 30 months after the date of delivery ]
Tender For supply of blower spares for ventilation system of njhps sjvn limited jhakri - taper bore pulley for ah as per ts and drawing enclosed , taper lock bush 3535 as per ts enclosed , taper lock bush 5050 as per ts enclosed , v belt c72 as per ts enclosed , v spc 6000 as per ts enclosed , v spc 6700 as per ts enclosed , v spc 7100 as per ts enclosed , plummer block sni 528 or equivalent as per ts and drawing enclosed , pulley for ahu fan as per ts, drawing and qap enclosed