Web Analytics Made Easy - StatCounter

Barge Hiring Tenders

Get complete information related to latest Barge Hiring Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Barge Hiring Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Barge Hiring Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :36269809 Due date: 08 Jun, 202408 Jun, 2024 13.94 Lacs
Tender For supply of miscellaneous electricals items for oh of unit 11 btps, obra - silica gel breather (as per sample) metallic body. silica gel capacity: - 500 gm flange connecting to conservator pipe size: - inch., epoxy resin cast insulator 6.6kv ( as per sample), electrolyte copper transformer stud with brass chuck nut and nut with washer, 19 mm. dia and 300 mm long. ( as per sample), epoxy bushing for lv side service transformer total length: - 408mm copper length: - 93 mm x16mm (2 length) poxy length:- 101 mm x 20 mm (2 length) (as per sample), flexible link for service transformer (as per sample), neoprene rubber sheet 1x2mtr. thick- 03mm, rubber gasket of size 14 (as per sample), ns2 hrc fuse cartridge 2a, hrc fuse ns 4 amp, ns6, hrc fuse cartridge,6a, ns10,hrc fuse cartridge,10a,220v dc+/dc, hrc fuse, ns- 16 amp, p2plbr3l, led lamp, plastic range, label: green colour lens, suitable for 220v dc bkr. off, led indicating lamp 220-240 dc redmake- abb/siemens/l&t/c&s/schneider, abb make pilot light with integrated led 220v dc white, auto manual selector switch, mcb. voltage :440 v ac (4 pole) current :6 amp, with aux contact : 1 no+1 nc make: siemens/l&t/schneider/havells/abb., mcb voltage: 220 v dc (2 pole) current: 10 amp, with aux contact: 1 no+1 nc make: siemens/l&t/schneider/havells/siemens., local/remote selector swith, tap position indicator 1-17 tap,04-20 ma input signal,make-m/s rishabh instrument pvt ltd, current relay type: pt 40/0.2-t, ih :0.5-1.0 ,50-60 hz, setting range :0.05-0.06-0.07-0.08-0.09-0.10, 1cx2.5 sq.mm 1.1kv,grade single core cu conductor pvc(red/yellow/blue) insulated wire as per is:694 (each packetcontain bundle of 90 meter cu wire), voltmeter dc moving iron jewel bearing r-(-15v-0-+15v)accuracy2.5%, mcb. voltage: 440 v ac (4 pole) current: 16 amp with aux contact: 1 no+1 nc. make: siemens/ l&t/ schneider/ havells/abb, over load relay assembly) phase failure with uv/ov relay 415 vac, volats part no.-acs2vmr3, winding temp. indicator, digital multimeter dm-104, grinding motor o/l relay class type 0116, universal digital indicator i/p ma,0-10 vdc, mv o/p 4-20ma, digital energy meter connection :- 3 phase, 3 wire ct ratio:- 10000/5 amp pt ratio:- 1575 kv/110 v,50 hz, acc class: -02 operati, transformer pt-415v/110v, control transformer, t-1input voltage 0-440v, output s1, 0-110-120 and s2 0-110-120 (as per sample) rating 50va, control transformer, t-2, input voltage 0-440v, output 0-18-24 (as per sample) rating 50va, breather as per sample, led tube light with batton 1x20w (retrofit) (t5) complete fitting, output lumen >1600 lm (make-havells, bajaj, philips, surya,crompton, eveready & syska), led tube light 20 watt (make-havells, bajaj, philips, surya, crompton, eveready & syska), 9w led bulb, output lumen/watt=>100 lm/w(make-havells, bajaj, philips, surya, crompton, eveready & syska), lighting panel 415v industrial 60a 3phase, ictp switch 63 amp, ictp switch 200 amp, tb 100a per ldb, 200w led flood light complete fitting(make-havells, bajaj, philips,surya, crompton, eveready & syska), 110 w led flood light ( with fitting & mounting accessories )(make-havells, bajaj, philips, surya, crompton, eveready & syska), 70 led flood light complete fitting(make-havells, bajaj, philips,surya, crompton, eveready & syska), 40w led high bay complete fitting(make-havells, bajaj, philips,surya, crompton, eveready & syska), 2.5 mm pvc insulated single core copper conductor cable, 4 mm pvc insulated single core copper conductor cable, 63 a four pole mcb make: siemens/ l&t/ schneider/ havells/abb, mcb 20a sp make: siemens/ l&t/ schneider/ havells/abb

CTN :36240988 Due date: 31 May, 202431 May, 2024 NA
Tender For supply of contactor -25a, 04 pole, rated insulation voltage-690v, rated operational voltage-415v, rated im pulse withstand voltage-8kv, service temperature--20 degree c to 55 degree c, voltage available for 50 hz opn- 110, 220, 240, 415 pick-up-68va, hold-on-11va, 4w, limits of operation pick-up (%)- 55-120, drop-off (%)- 30-5 0, mounting dimensions h x w in mm- (60 - 65 - 70) x 35, overall dimensions h x w x d in mm-83 x 45 x 83.7, make: abb, l&t, schneider, havells, c&s [ warranty period: 18 months after the date of delivery ]

Central Government/Public Sector

CTN :36177849 Due date: 23 May, 202423 May, 2024 23.72 Lacs
Tender For providing of custom bid for services - 200134226 maintenance contract of ci systems and equipments for fgd area at ntpcunchahar stage4 for one year- 10) maintenance contract of c&i systems and equipments for fgd area at ntpc-unchahar stage-4. 10.10 item service code no.: cipna00gn400 desc:- removal & remounting of pneumatic actuator(diaphragm type or power cylinder type) will consists of any combination of following activities: 1. removal of pneumatic connections and required instruments like solenoid valve, limit switch, afr, positioner, pft etc from actuator and decoupling from valve after ensuring proper isolation from process side. 2. removal of actuator from its position. 3. transportation of actuator from its location to a safe place. 4. remounting the actuator after clearance from mechanical maintenance. 5. re-fixing /replacing the related accessories removed earlier as per point no-1 above and restoring pneumatic connections including cable dressing, copper tubing, tagging etc. 6. final operation checking from local & control room (fgd ddcmis system) after calibration and feedback adjustment. defect liability period: 01 week 10.20 item service code: - cipna00gn106 des:- checking/pm of pneumatic control system pneumatic actuator (diaphragm type or power cylinder type) and its mounted accessories, will consists of any combination of following activities: a) checking/pm of solenoid valves mounted on pneu. act. i. check solenoid coil physical and electrical healthiness and tightness of terminals if required ii. clean its external parts. iii. check & adjust air supply pressure as per requirement iv. check tightness checking of all parts. v. energize with correct voltage and see solenoid valve operation if required as per instruction of area in charge. vi. if solenoid valve is not working or coil resistance is not adequate replace solenoid valve or coil and check operation. vii. tighten checking of wires at terminals & at junction boxes. b) checking/pm of positioner and position feedback transmitter mounted on pneu. act. i. check & adjust supply pressure as per requirement. ii. clean its external parts of positioner and check its operation, if necessary, as per instruction of area in charge. iii. if required, connect pneumatic test signal at i/p, 0.2 kg/cm2. adjust positioner zero adjustment spring, till actuator comes to zero position. adjust 4ma o/p of pft with zero pot. iv. raise pneumatic test signal to 1.0 kg/cm2 and adjust span of positioner, till actuator reaches 100% position. adjust 20ma o/p of pft with span pot. v. repeat steps ii to iv till the required repeatability is achieved. vi. tighten terminals at junction boxes. c) removal and restoration of c&i connections as per requirement during unit shutdown or as per requirement. i. removal of accessories like solenoid valves, positioner, i/p converter, air lock relay, air filter, air filter regulator, limit switch, position feedback transmitter, volume booster, pneumatic lines, etc. ii. keeping all accessories safely at suitable location. iii. restoration of all accessories removed and connection of air lines as per original scheme. iv. checking of functioning of actuator after restoration of connection. v. calibration / adjustment of complete system if required. d) checking/pm of i/p converter/smart positioners if any i. adjust supply pressure as per requirement. ii. check ma input to i/p converter/smart positioner. iii. check i/p converter/smart positioner o/p with portable gauge. it should correspond to its characteristic, if not, remove it and send to c&i lab for calibration/repair. iv. bring i/p converter/smart positioner from c&i lab and fit it in line. v. connect ma signal and normalize the system. vi. tighten terminals at junction box. e) checking/pm of regulating type actuator operation. i. check and adjust supply air pressure as per requirement of respective actuator. ii. set demand to 0% from control room after taking p

corporations/Associations/Others

CTN :36131550 Due date: 20 May, 202420 May, 2024 13.94 Lacs
Tender For corrigendum : supply of miscellaneous electricals items for oh of 11 btps, obra - silica gel breather (as per sample) metallic body. silica gel capacity: - 500 gm flange connecting to conservator pipe size: - inch., epoxy resin cast insulator 6.6kv ( as per sample), electrolyte copper transformer stud with brass chuck nut and nut with washer, 19 mm. dia and 300 mm long. ( as per sample), epoxy bushing for lv side service transformer total length: - 408mm copper length: - 93 mm x16mm (2 length) poxy length:- 101 mm, 20 mm (2 length) (as per sample), flexible link for service transformer (as per sample), neoprene rubber sheet 1x2mtr. thick- 03mm, rubber gasket of size 14 (as per sample), ns2 hrc fuse cartridge 2a, hrc fuse ns 4 amp, ns6, hrc fuse cartridge,6a, ns10,hrc fuse cartridge,10a,220v dc+/dc, hrc fuse, ns- 16 amp, p2plbr3l, led lamp, plastic range, label: green colour lens, suitable for 220v dc bkr. off, led indicating lamp 220-240 dc redmake- abb/siemens/l&t/c&s/schneider, abb make pilot light with integrated led 220v dc white, auto manual selector switch, mcb. voltage :440 v ac (4 pole) current :6 amp, with aux contact, 1 no+1 nc make: siemens/l&t/schneider/havells/abb., mcb voltage: 220 v dc (2 pole) current: 10 amp, with aux contact: 1 no+1 nc make: siemens/l&t/schneider/havells/siemens., local/remote selector swith, tap position indicator 1-17 tap,04-20 ma input signal,make-m/, rishabh instrument pvt ltd, current relay type: pt 40/0.2-t, ih :0.5-1.0 ,50-60 hz, setting range :0.05-0.06-0.07-0.08-0.09-0.10, 1cx2.5 sq.mm 1.1kv,grade single core cu conductor pvc(red/yellow/blue) insulated wire as per is:694 (each packetcontain bundle of 90 meter cu wire), voltmeter dc moving iron jewel bearing r-(-15v-0-+15v)accuracy2.5%, mcb. voltage: 440 v ac (4 pole) current: 16 amp with aux contact: 1 no+1 nc. make: siemens/ l&t/ schneider/ havells/abb, over load relay assembly) phase failure with uv/ov relay 415 vac, volats part no.-acs2vmr3, winding temp. indicator, digital multimeter dm-104, grinding motor o/l relay class type 0116, universal digital indicator i/p ma,0-10 vdc, mv o/p 4-20ma, digital energy meter connection :- 3 phase, 3 wire ct ratio:- 10000/, amp pt ratio:- 1575 kv/110 v,50 hz, acc class: -02 operati, transformer pt-415v/110v, control transformer, t-1input voltage 0-440v, output s1, 0-110-120 and s2 0-110-120 (as per sample) rating 50va, control transformer, t-2, input voltage 0-440v, output 0-18-24 (as, sample) rating 50va, breather as per sample, led tube light with batton 1x20w (retrofit) (t5) complete fitting, output lumen >1600 lm (make-havells, bajaj, philips, surya,crompton, eveready & syska), led tube light 20 watt (make-havells, bajaj, philips, surya, crompton, eveready & syska), 9w led bulb, output lumen/watt=>100 lm/w(make-havells, bajaj, philips, surya, crompton, eveready & syska), lighting panel 415v industrial 60a 3phase, ictp switch 63 amp, ictp switch 200 amp, tb 100a per ldb, 200w led flood light complete fitting(make-havells, bajaj, philips,surya, crompton, eveready & syska), 110 w led flood light ( with fitting & mounting accessories )(make-havells, bajaj, philips, surya, crompton, eveready & syska), 70 led flood light complete fitting(make-havells, bajaj, philips,surya, crompton, eveready & syska), 40w led high bay complete fitting(make-havells, bajaj, philips,surya, crompton, eveready & syska), 2.5 mm pvc insulated single core copper conductor cable, mm pvc insulated single core copper conductor cable, 63 a four pole mcb make: siemens/ l&t/ schneider/ havells/abb, mcb 20a sp make: siemens/ l&t/ schneider/ havells/abb

Central Government/Public Sector

CTN :36115555 Due date: 31 May, 202431 May, 2024 NA
Tender For a)csmt- replacement of the corroded and leaky over head tanks and pipelines at nab and annex building csmt mumbai. b) csmt- painting of service building, tms building, station building at pf-18, reservation building combined crew running and booking office lobby (mainline) at pf 18 with minor plaster and ceiling repairs. c) proposal for cutting of coping slab of platforms at csmt exceeding the permissible limit of horizontal distance from centre of track. d) csmt- replacement of c&w staff room and improvement in circulating area near platform -10 csmt station. e) csmt- provision of grill to window of sr. dom office, tms building under aden (w) csmt. f) bp- repairs of terraces, parapet wall and chajjas of l,a,e,f block, roshera mahal and janjeera chambers of badhwar park
 Loading, Please wait...

Connect us via What's Up