Get complete information related to latest Barrier Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Barrier Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Barrier Repair Tenders.
Tender For various works in sub tehsil longowal - patwari cabins:-scraping cement outer plaster, scraping cement inner plaster, cement rendering on plaster 1mm thick, 12.5 mm thick cement plaster 1:4, 20mm thick cement paster 1:4, first class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level., 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure, 12.5 mm thick cement plaster 1:5, 20mm thick cement paster 1:5, preparation of plastered or concrete surface or painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish, applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface, distempering with acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade, finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sq, providing and laying vitrified floor tiles in different sizes in light colour shades made using full body technology (thickness to be specified by the manufacturer) with water absorption s less than 0.08% and conforming to is : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) size 600x600 mm, providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance (rh) of 99%, light reflection > 85%, thermal conductivity k = 0.052 - 0.057 w/m k, fire performance as per (bs 476 pt - 6 &7)in true horizontal level suspended on interlocking t-grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized@120 gsm) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter m-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main t . the system should rest on periphery walls /partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of theengineer-in-charge.with 16 mm thick beveled tegular mineral fibre false ceiling tile (nrc 0.55 to 0.6)size 595x595 mm, earth work in excavation in foundations trenches etc. in all kinds of soil where pick-jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres., cement concrete 1:8:16 with stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type, first class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth, base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mix
Tender For corrigendum : supply of repair of boom barrier , repair of ptz camera , repair of megaphone , repair of licnse plate camera , repair of rfid sys with lan , repair of rfid cards with lanyard , repair of management console , repair of bio metric door lock , repair of high capicity search light , hand held metal detector , repair of electric siren , repair of online ups 5 kva , nas 2tb , traffic cones , repair of printer , onu , repair of gepon , under vehicle search mirror , repair of digiatal video camera
Tender For supply of media converter repair for cctv camera , solar street light repair , junction box repair for cctv camera , body cam repair , veh tracker repair for e- rikshaw , gps tracker repair , plastic road barrierrepair