Get complete information related to latest Battery Tray Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Battery Tray Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Battery Tray Tenders.
Tender For supply of contactor 3 pole, 24v dc, 50 amps suitable for starter battery charging control panel for use in dg set equipped in lhb power car as per edts-116 rev-a or lat. make as per bom of edts -116 rev-a o f abb cat no. af50-30-00, 24v dc or equivalent of schneider / siemens / c&s / eaton. [ warranty period: 30 months after the date of delivery ]
Tender For supply of emergency battery charger unit, capacity 10a, input voltage 415v ac, 3 phase, o utput 24v dc confirming to icf spec. no. icf/elec/841, rev. a suitable for garib rath type ac c oaches. [ warranty period: 18 months after the date of delivery ]
Tender For corrigendum : supply of ni cd battery and accessories for ennore project - 220v dc ni-cd battery for supplying 220v suitable ampere hourah high discharge ni-cd pocket plate battery bank as per load cycle for chp mcc-01 near crusher house as per annexure-ii , 220v dc ni-cd battery for chp mcc01 near crusher house list of ni-cd battery accessories for chp mcc-01 near crusher house as per annexure-iii , 220v dc ni-cd battery for chp mcc-01 near crusher house ni-cd battery mandatory spares as per annexure-iv , 220v dc ni-cd battery for supplying 220v suitable ampere hourah high discharge ni-cd pocket plate battery bank as per load cycle chp mcc-02 near bunker area as per annexure-ii , 220v dc ni-cd battery for chp mcc-02 near bunker area list of ni-cd battery accessories for chp mcc-02 near bunker area as per annexure-iii , 220v dc ni-cd battery for chp mcc-02 near bunker area ni-cd battery mandatory spares as per annexure-iv , 220v dc ni-cd battery for supplying 220v suitable ampere hour ah high discharge ni-cd pocket plate battery bank as per load cycle for ahp mcc-01 near compressor house as per annexure-ii , 220v dc ni-cd battery for ahp mcc-01 near compressor house list of ni-cd battery accessories for ahp mcc-01 near compressor house as per annexure-iii , 220v dc ni-cd battery for ahp mcc-01 near compressor house ni-cd battery mandatory spares as per annexure-iv , 220v dc ni-cd battery for ahp mcc-01 near compressor house ni-cd battery commissioning spares as per annexurev , ni-cd battery supervision of e and c lump sum charges per visit for engineer except daily charges , ni-cd battery supervision of e and c lump sum daily charges for engineer , type test for chp mcc-01 near crusher house test for discharge performance at low temperature , type test for chp mcc-01 near crusher house ampere hour capacity , type test for chp mcc-01 near crusher house retention of cahrge , type test for chp mcc-01 near crusher house life cycle test , type test for chp mcc-02 near bunker area test for discharge performance at low temperature , type test for chp mcc02 near bunker area ampere hour capacity , type test for chp mcc-02 near bunker area retention of cahrge , type test for chp mcc-02 near bunker area life cycle test , type test for ahp mcc-01 near compressor house test for discharge performance at low temperature , type test for ahp mcc-01 near compressor house ampere hour capacity , type test for ahp mcc-01 near compressor house retention of cahrge , type test for ahp mcc-01 near compressor house life cycle test
Tender For supply of 250ma for mhs, maithon, dvc , potentiometer for manual voltage adjustment 10k ohm_3w for phps, panchet, dvc , potentiometer for manual voltage adjustment 10k ohm_3w for mhs, maithon, dvc , sync. transformer for scr controller unit for 150a float-cum-boost charger, 0-270- 300v_80-0-80v, 100ma for phps, panchet, dvc , sync. transformer for scr controller unit for 150a float-cum- boost charger, 0-270-300v_80-0-80v, 100ma for mhs, maithon, dvc , filter capacitor, 4700 micro farad_ 350 volt dc for phps, panchet, dvc , filter capacitor, 4700 micro farad_ 350 volt dc for mhs, maithon, dvc , blocking diode for battery charger for phps, panchet, dvc , blocking diode for battery charger for mhs, maithon, dvc , ac supply fail relay card static type 415v ac for phps, panchet, dvc , ac supply fail relay card static type 415v ac for mhs, maithon, dvc , semiconductor protection fuse, high speed, 200a for phps, panchet, dvc , semiconductor protection fuse, high speed, 200a for mhs, maithon, dvc , thyristor 150a, 1200v _h150tb12 for phps, panchet, dvc , thyristor 150a, 1200v _ h150tb12 for mhs, maithon, dvc , battery protection fuse _200 a hrc type for phps, panchet, dvc , battery protection fuse _200 a hrc type for mhs, maithon, dvc , dc voltmeter selector switch _16a, 1pole, 4 way spa3116d for phps, panchet, dvc , dc voltmeter selector switch _16a, 1pole, 4 way spa3116d for mhs, maithon, dvc , integrated dc sensing module consisting of circuit - ch. failure, dcu_ovr, befr, fbcor, sfr, auto equalise for phps, panchet, dvc , integrated dc sensing module consisting of circuit - ch. failure, dcu_ovr, befr, fbcor, sfr, auto equalise for mhs, maithon, dvc , dc power supply for idsr card _static type, 24 v and 12 v dc for 150a float cum boost charger _make_ chloride for phps, panchet, dvc , dc power supply for idsr card _static type, 24 v and 12 v dc for 150a float cum boost charger _make_ chloride for mhs, maithon, dvc
Tender For purchase of tools and miscellaneous - purchase of tools and miscellaneous, digital clamp meter meco 36 auto40/400 amp ac/dc meter, nitrile safety glovesmedium size 100 pairs, ss screw star head1/2", ss screw star head1", battery terminal protectorspray/gel, aluminium ladder heavy6 feet a type, air blower 650w, dry wall screw3/4", dry wall screw1", chain block0.5 ton, chain block1 ton, chain block2 ton, chain block5 ton, industrial pedal fanalmonard, oxygen regulator with back fire arrestor, acetiline regulatorwith back fire arrestor, battery charge analyser, power hammer, hydrolic press havy110-130 ton
Tender For supply of static frequency converter 115v 1 ph 400 hz 20 kva pt no u203q20z , transformer rectifier unit 27v dc pt no 5uc 6860na sl no 20121203434 , automatic battery charger pt no 5p 0053na sl no 2xk01240 , static frequency converter 208 v 3 ph 400 hz 60 kva u603r30z sl no 080402 , transformer rectifier unit 27v dc pt no 3pr 27 250a sl no 135 0692 , automatic regulator type 863 4 pt no 5p niv sl no 992 1015 , tester battery capacity type 2 pt no re4000c sl no se abcd 101 2017 , static frequency converter 115v 1 ph 400hz 20 kva pt no u203q20z , static frequency converter 36v 3ph 400hz 05 kva pt no u502r10z , automatic regulator type 863 4 pt no 5p niv sl no 992 1014 , transformer rectifier unit 24v to 36v pt no 5uc 6860na sl no 20121203435