Web Analytics Made Easy - StatCounter

Bio Chemistry Analyzer Tenders

Get complete information related to latest Bio Chemistry Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bio Chemistry Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bio Chemistry Analyzer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Private Sector

CTN :45740117 Due date: 22 Jul, 202622 Jul, 2026 44.95 Lacs
Tender For supply, installation and commissioning of rf spectrum analyzer for tifr, hyderabad

Central Government/Public Sector

CTN :43926323 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For bid to ras bid to ras corrigendum : supply of vna with noise source , rf peak power meter , spectrum analyzer , hi precision digital multimeter , coax to wg adaptors , dc smr , dc mlat , dummy load , tool kit smr mlat

CTN :44479008 Due date: 01 Jul, 202601 Jul, 2026 7.67 Crore
Tender For bid to ras bid to ras bid to ras bid to ras bid to ras corrigendum : supply of digital oscilloscope , optical spectrum analyser , arbitrary waveform generator , fiber optic power meter (nano-watt) , fiber optic power meter (pico-watt) , programmable dc power supply , time tagger (tcspc) , single photon avalanche diode (spad) detector , mixed signal oscilloscope , optical time domain reflectometer (otdr) , real time rf spectrum analyzer

CTN :44736005 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For bid to ras supply of rf spectrum analyzer

State Government

CTN :43556933 Due date: 10 Jul, 202610 Jul, 2026 9.97 Crore
Tender For corrigendum : re-tender for supply and installation of semi- automated bio chemistry analyzer under nfds & nuhm programme for the year 2024-25 under 15th finance budget

Central Government/Public Sector

CTN :45722220 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For alt0102(sgpt) alt (4* 35ml+ 2* 18ml) (qty- 04 kit) , ast0102 (sgot) kit (mr) 4* 35 ml+ 2* 18ml (qty- 04 kit) , alp0102alp (4* 35+ 2* 18ml) (qty- 04 kit) , bilirubin total dsa (4* 20+ 1* 20) -mindray (qty- 04 kit) , ure0102urea (4* 35+ 2* 18) - mindray (qty- 04 kit) , creatinine (2 x 27+ 1 x18 ml) mindray (qty- 04 kit) , uricacidkit (mr) 4* 40+ 2* 20ml (qty- 04 kit) , hba 1c kit (1x40+ 1x15+ 1x200+ 2x1 ml calibrator) mr (qty- 03 kit) , total cholesterol kit (mr) 4* 40 ml (qty- 04 kit) , triglycerides kit (mr) 4* 40 ml (qty- 04 kit) , distilled water 5 ltr for biochemistry analyzer (qty- 144 nos) , cd80 detergent bottle for biochemistry analyzer (qty- 12bottle) , biochemistry analyzer lamp with 2000 hours lamplife (qty- 02 nos) , cuvetts for mindray biochemistry analyzer (qty- 04 pack) , sample/reagent analyzer probe (qty- 01 nos) , reagent syringe for biochemistry analyzer (bs-240) (qty - 01nos) , hdl calibrator for biochemistry analyzer for mindray (bs- 240) (qty-04 vial) , multi calibrator for biochemistry analyzer for mindray (bs-240) (qty- 04 vial) , hdl cholesterol kit 1* 40+ 1* 14 ml (mr) (qty-04 kit) , preventive maintenance (pm) kit for biochemistry analyser for mindray (bs-240) , quality control for bio chemistry analyzer for mindray (bs-240) , sample syringe for biochemistry analyzer for mindray (bs-240) , glucose kit god pod method (mr) 4* 40+ 2* 20ml (qty-09 kit)

CTN :45597271 Due date: 02 Jul, 202602 Jul, 2026 31.98 Lacs
Tender For supply of rf analyzer or spectrum analyzer , sdr system complete usrp b210 and antennas and lna filter kit , rf signal generator , digital storage oscilloscope , logic analyzer , benchtop inductance capacitance resistance meter , smd rework station , esd work benches , precision esd toolkit and microscope , rf cables and adapters kit , vna calibration kit , high end desktop workstation for diagnostics mil grade , c two software , rf shielded enclosure faraday cage , bench power supply , building earth and earthing pit , centralised ups online system , mil grade electrical works , fire and smoke alarm system , rf safety devices , annual calibration year one

Central Government/Public Sector

CTN :45550309 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For supply of rf spectrum analyzer, make- keysight n9344c or make- owon, hsa1075/hsa1075-tg or make -signal hound bb60c/bb60d or similar [ warranty period: 30 months after the date of delivery ] ]

CTN :45515971 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For rf multiport spectrum analyzer

CTN :45446505 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont
 Loading, Please wait...

Connect us via What's Up