Get complete information related to latest Borehole Camera Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Borehole Camera Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Borehole Camera Tenders.
Tender For corrigendum : supply of training room - p.a. system, (1.1) amplifier, (1.2) ceiling speaker, (1.3)collar mic., (1.4) table mic., (1.5) hand held mic., 98 inch t.v., white board (6 feet x 4 feet) with moveable stand., all in one pc, room size
Tender For bid to ras corrigendum : supply of portable pa system with accessories d d - speaker srx 815 , amplifier xti 6000 , mixer mg12xu , speaker cable 2.5 sqmm 25mtr , speaker cable 2.5 sqmm 50mtr , xlr male and female pair , tripod speaker stand , mic corded , cord for mic 25mtr , aux cable 10mtr , aux cable 20mtr , aux cable 02mtr , 10 socket extension board with 100mtr wire
Tender For bid to ras supply of smart tv 85 inch , pa system 680w with mic , 30w ceiling speaker , home theater , microwave oven , mixer grinder , induction crockery plate
Tender For corrigendum : providing of custom bid for services - hiring of stage banners, standies, pa system, tentage, yoga mates and refreshment for conduct of international day of yoga at sudershan setu.
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t
Tender For erection of police camp, bunker shed along with scissor barricades, drop gate and p.a. system store at fort william on the different road side of maidan area on the occasion of republic day parade on 26th january, 2026
Tender For erection of temporary pandal, platform, iron stage for commentry box, p.a. system console room, anti chamber and allied work and supply of chair on the occasion of republic day parade on 26th january, 2026.
Tender For operation and maintenance of pa system installed at council chamber (house), blro department, birth and death certificate office and other areas in cmo building.