Get complete information related to latest Breaker Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Breaker Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Breaker Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :38474066 Due date: 23 Dec, 202423 Dec, 2024 NA
Tender For corrigendum : supply of switchgear amc for mdpl - ht breaker _isolator servicing at mundra , lt breaker servicing at mundra , earthing trolley maintenance at mundra , relay calibration _electromec_ at mundra , relay calibration _numerical_ at mundra , relay calibration _aux_ at mundra , vacuum bottle testing at mundra , 3rd harmonic test-la_surge arr at mundra , calibration-kwh,mw,mva,mvar at mundra , calibration-multifunction meter at mundra , thermography-station equipment at mundra , breakdown visits mandays at mundra , ht breaker _isolator servicing at bachau , lt breaker servicing at bachau , earthing trolley maintenance at bachau , relay calibration _electromec_ at bachau , relay calibration _numerical_ at bachau , relay calibration _aux_ at bachau , vacuum bottle testing at bachau , 3rd harmonic test-la_surge arr at bachau , calibration-kwh,mw,mva,mvar at bachau , calibration-multifunction meter at bachau , thermography-station equipment at bachau , breakdown visits mandays at bachau , ht breaker _isolator servicing at santalpur , lt breaker servicing at santalpur , earthing trolley maintenance at santalpur , relay calibration _electromec_ at santalpur , relay calibration _numerical_ at santalpur , relay calibration _aux_ at santalpur , vacuum bottle testing at santalpur , 3rd harmonic test-la_surge arr at santalpur , calibration-kwh,mw,mva,mvar at santalpur , calibration-multifunction meter at santalpur , thermography-station equipment at santalpur , breakdown visits mandays at santalpur , ht breaker _isolator servicing at palanpur , lt breaker servicing at palanpur , earthing trolley maintenance at palanpur , relay calibration _electromec_ at palanpur , relay calibration _numerical_ at palanpur , relay calibration _aux_ at palanpur , vacuum bottle testing at palanpur , 3rd harmonic test-la_surge arr at palanpur , calibration-kwh,mw,mva,mvar at palanpur , calibration-multifunction meter at palanpur , thermography-station equipment at palanpur , breakdown visits mandays at palanpur , ht breaker _isolator servicing at pindwara , lt breaker servicing at pindwara , earthing trolley maintenance at pindwara , relay calibration _electromec_ at pindwara , relay calibration _numerical_ at pindwara , relay calibration _aux_ at pindwara , vacuum bottle testing at pindwara , 3rd harmonic test-la_surge arr at pindwara , calibration-kwh,mw,mva,mvar at pindwara , calibration-multifunction meter at pindwara , thermography-station equipment at pindwara , breakdown visits mandays at pindwara , ht breaker _isolator servicing at auwa , lt breaker servicing at auwa , earthing trolley maintenance at auwa , relay calibration _electromec_ at auwa , relay calibration _numerical_ at auwa , vacuum bottle testing at auwa , 3rd harmonic test-la_surge arr at auwa , calibration-kwh,mw,mva,mvar at auwa , calibration-multifunction meter at auwa , thermography-station equipment at auwa , breakdown visits mandays at auwa , ht breaker _isolator servicing at ajmer , lt breaker servicing at ajmer , earthing trolley maintenance at ajmer , relay calibration _electromec_ at ajmer , relay calibration _numerical_ at ajmer , vacuum bottle testing at ajmer , 3rd harmonic test-la_surge arr at ajmer , calibration-kwh,mw,mva,mvar at ajmer , calibration-multifunction meter at ajmer , thermography-station equipment at ajmer , breakdown visits mandays at ajmer , ht breaker _isolator servicing at jaipur , lt breaker servicing at jaipur , earthing trolley maintenance at jaipur , relay calibration _electromec_ at jaipur , relay calibration _numerical_ at jaipur , vacuum bottle testing at jaipur , 3rd harmonic test-la_surge arr at jaipur , calibration-kwh,mw,mva,mvar at jaipur , calibration-multifunction meter at jaipur , thermography-station equipment at jaipur , breakdown visits mandays at jaipur , lt breaker servicing at vadodara , relay calibration _electromec_ at vadodara , relay calibration _numerical_ at vadodara , calibrationmultifunction meter at vadodara , thermo

CTN :38525561 Due date: 26 Dec, 202426 Dec, 2024 NA
Tender For rfp for supply of various electrical material at i/a sez-ii, pithampur, distt. dhar (m.p.) - supply installation testing and commissioning of 132kv ct having ratio of 400/1-1-1 a., supply of 33kv ct having ratio of 400/1-1-1 a. as per standart of mpptcl top bottam standard., supply installation testing and commissioning of 220/132/33kv s/s sec.-3 support abt, 3phase 4wire meter, class 0.2s make secure., supply installation testing and commissioning of 200 kva conventional 5star distribution transformer., supply installation testing and commissioning of 18 unit for 12mvar capacitor bank at 132kv s/s, supply installation testing and commissioning of 10kva/48v invertor cum battery for custom office use at niryat bhavan sez-ii., supply installation testing and commissioning of 110volt. 300ah make hertz electronics at 132kv s/s sez-ii., supply installation testing and commissioning of 48 volt. 200ah make hertz electronics at 132kv s/s sez-ii., supply copper control cable 12 core. 2.5 sq.mm. (armoured), supply ct clamp sutable for 11 kv ct, supply 33 kv ttb, supply 11 kv ttb, supply 33 kv vcb, outdoor porcelain clad type with complete structure and accessories including existing control pannel wiring for feeder protection excluding ct & pannel, supply33 kv ct 1200/1 amp as per standart of mpptcl top bottam standard., supply33 kv ct outdoor oil immersed type 400-200/5-5 amp, supply secure meter 0.2 clss accuracy premier series 300 3phase 4 wire, supply 33 kv control & relay panel with over current and earth fault static relay for transformer & feeder protection (avana), sitc 33 kv vcb, outdoor porcelain clad type with complete structure and accessories ct & breaker excluding ct & pannel, supply 11 kv ct outdoor oil immersed type 300-150/5-5 amp, supply handling & installation of 33 kv feeder/xmer vcb complete on foundation & tightening/ alingment of of vcb. with old vcb dismentling, supply handling & installation of control pannel , including stand of suitable size for 33/11kv feeder and transformer control, supply installation testing and comissioning 33kv isolator 800amp. copper contactors., supply dlms compliant single phase electronic meter with data downloading facility & box 5-30 amps secure, genus., supply three phase whole current smart meter with box 10-100 a with data downloading facility & box, supply testing and commissionnng of vcb and control pannel, supply sheet metal meter box suitable for h.t. static travector meters with ttb, supply copper control cable 2 core. 2.5 sq.mm. (armoured), supply copper control cable 4 core. 2.5 sq.mm. (armoured), supply copper control cable 8 core. 2.5 sq.mm. (armoured), supplycopper control cable 10 core. 2.5 sq.mm. (armoured), supply copper control cable 12 core. 2.5 sq.mm. (armoured), supply aluminium cable 2 core. 4 sq.mm. (unarmoured), 2 x c al 10 sqmm cable, 2 x c al 16 sqmm cable, 1 x c copper 2.5 sqmm wire, 100 amps mcb, supply junction box for hymast and street lights with inbuild 100 amps mcb for main supply & 63 amps for outgoing supply for hymast and street lights, supply 16 sqmm cable al 4 x c (four-core) (non-abc) having cloth covering suitable for hymast connection, supply 25 sqmm cable al 4 x c ( four core) armoured cable (non abc) for providing 3 phase supply to hymast, supply pvc insulation tape, supply 4 point connectors for hymast, supply 25 sqmm lugs for hymast cables, supply 2.5 sqmm cu flexible wire, supply pvc tape 2*30(box), supply m seal, supply ferrule (r,y,b,n and 0 to 9) each 1 set, supply pvc insulated pvc sheathed 3.5 core 35 sqmm aluminium conductor 1100 volts, supply pvc insulated 2 core 10 sqmm cable

State Government

CTN :38515876 Due date: 21 Dec, 202421 Dec, 2024 NA
Tender For work of cleaning of 220v dc / 415v /6.6 kv bus / module / breaker/panel /ht motor/lt motor/hmv/cable gallery by compressed air on " as and when required basis" during normal running/aoh / coh of stage-ii at wtps.

corporations/Associations/Others

CTN :38458133 Due date: 04 Jan, 202504 Jan, 2025 NA
Tender For upgradation of existing indoor 11 kv ht oil circuit breaker switchgear panels by vaccum circuit breaker switchgear panels in main receiving station and 11kv v /415 v indoor substation no.v

CTN :38365575 Due date: 18 Dec, 202418 Dec, 2024 24.08 Lacs
Tender For supply of field switch spares for electric rope shovel at kathara ocp on open tender enquiry basis - rectifier bridge unit 60 by63a 600piv 100v , machanism motor wound spring charged 25k , switch auxiliary assembly , spring charging motor , mechanism catch 25ka , shunt trip coil 110 v dc , fuse,ht,pt,11kv,5a , current transformer ctr 600_300by5 , relay e l 50a 1a 110v ac , idmtl relay 2o c and1 e f with instantan , anti pumping relay 11 pin 110v ac , block contact 2no for pb , expoxy resin cast current transformer 20 , interruptr assy.complet transfer flex. , epoxy insulator , spaut circuit , switch control breaker pistol grip , shunt trip coil assembly110v dc , electric release_closing coil assly.110v , auxiliary switch assembly , 16 pin plug and socket assly. , vacuum interrupter , selector switch for voltmeter , selector switch for ammeter , core balance transformer lt , plug and socket assly -pommel , auxiliary contactor , rectifier capacitor unit , pilot relay 110v dc , push button , fuse base carrier with link , master tripping relay , pt fuse 3.3kv 3 amp , motor protected relay , over current relay , pt dl vltg,6.6kv-3.3kv by110v,3p,2.5 kva , lt fuse for control circuit , hirc fuse for pt ht side , timer , local remote switch , onn-off isolator , isolator moving contact set , isolator fixed contact set , epoxy support insulator , support insulator f-fxd type vcb , pt 6.6kv-3.3kv by 110v,100va per ph.3p , over-voltage relay , push to trip knob , power factor meter , ground check relay , time delay relay

Central Government And Public Sector

CTN :38292574 Due date: 19 Dec, 202419 Dec, 2024 68.32 Lacs
Tender For providing of custom bid for services - ustom bid for services -enabling contract for erection & commissioning of ba/bb board for unit # 3 & unit # 6 (mc-5261)- item 1 dismantling & removal ba: dismantling and removal of existing installation of floor mounted cubical type 6.6 kv, 3 phase, 50 hz, vacuum circuit breaker ba board containing 16 nos breaker panel, and approximate size 14000 mm x 2150 mm x 2800 mm (lxdxh) at ei. 7.5 mtr in unit switchgear room at electrical annex building of power house. all the scrap generated from this is to be shifted to the designated place at scrap yard as per the direction of the mic. 2.00 set, item 2 dismantling & removal bb: dismantling and removal of existing installation of floor mounted cubical type 6.6 kv, 3 phase, 50 hz, vacuum circuit breaker bb board containing 17 nos breaker panel, and approximate size 14500 mm x 2150 mm x 2800 mm (lxdxh) at ei. 7.5 mtr in unit switchgear room at electrical annex building of power house. all the scrap generated from this is to be shifted to the designated place at scrap yard as per the direction of the mic. 2.00 set, item 3 installation including issue-ba: installation including issue from nalco s store, transportation to erection site, storage at site, erection of floor mounted cubical type 6.6 kv, 3 phase, 50 hz, vacuum circuit breaker ba board containing 16 nos breaker panel, and approximate size 14000 mm x 2150 mm x 2800 mm (lxdxh) at ei. 7.5 mtr in unit switchgear room at electrical annex building of power house including supply of all erection accessories and consumable etc for complete and satisfactory installation of the switchboard in all respect.testing of all the 6.6kv panels including ct, pt, breakers, spds, logics and interlocks, auxiliary relays, numerical relays, cables(both ht and lt) 2.00 set, item 4 installation including issue-bb: "installation including issue from nalco s store, transportation to erection site, storage at site, erection of floor mounted cubical type 6.6 kv, 3 phase, 50 hz vacuum circuit breaker bb board containing 17 nos breaker panel, and approximate size 14500 mm x 2150 mm x 2800 mm (lxdxh) at ei. 7.5 mtr in unit switchgear room at electrical annex building of power house including supply of all erection accessories and consumable etc for complete and satisfactory installation of the switchboard in all respect.. testing of all the 6.6kv panels including ct, pt, breakers, spds, logics and interlocks, auxiliary relays, numerical relays, cables(both ht and lt) 2.00 set, item 5 dismantling of 6.6kv 3cx185 sqmm: dismantling of 6.6 kv (ue) grade xlpe insulated, armoured, aluminium conductor frls cables of following sizes on cable trays at cable trench/structures after removal of clamps, trefoil clamps etc. the cables shall be kept properly at the designated place as per the direction of mic and later hand over the same at the central store scrap yard. 3cx185 xlpe cable 3000.00 meter, item 6 dismantling of 6.6kv 1x500m: dismantling of 6.6 kv (ue) grade xlpe insulated, armoured, aluminium conductor frls cables of following sizes on cable trays at cable trench / structures after removal of clamps, trefoil clamps etc. the cables shall be kept properly at the designated place as per the direction of mic and later hand over the same at the central store scrap yard. 1cx500 xlpe cable 2500.00 meter, item 7 cable laying including issue 3cx185sqmm: cable laying including issue from nalco s store, transportation to erection site, storage at site of 6.6 kv (ue) grade xlpe insulated, armoured, aluminium conductor frls cables of following sizes on cable trays in cable trench/structures including supply of cable installation accessories viz clamps, trefoil clamps, nylon ties, identification tags, hooks, saddles, spaces, rawl plugs, anchor fasteners, bolts, nuts, washers, sealing materials for pipe sleeves, etc and all other consumable materials to render the system complete in all respect. 3cx185 sqmm xlpe cable. 3000