Get complete information related to latest Bridge Rectifier Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bridge Rectifier Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bridge Rectifier Tenders.
Tender For providing and fitting of essential items and allied material for snow clearance operation at nathatop sanasar road - supply, testing and commissioning of 48v smps float cum boost automotive battery charger with moveable trolley stand for snow operation at nathatop - sanasar roadgeneral technical requirements for battery charger suitable for 48v vrla type battery1.) type -float & float cum boost charger for vrla type, full wave, full controlled type. 2. ) ratings- 15 a float cum boost for 48v, 150 ah vrla type battery 3. ) ac input- i) voltage 415 vac 10%ii) frequency 50hz 5% iii) phase 3 - phase 4.) d.c.output voltage settings -nominal float fc 48/54.5v (adj. by + 20%, - 5% bc 48/66.5v (adj. by + 2%, - 5%) 5.) output current limit 15a 15a 6. ) power conversion ac to dc by means of three phase full wave, half controlled bridgerectifier consisting of thyristors and diodes. 7.) voltage regulation at bridge output. + 1% of set value for + 10% input voltage variations, 0-100% load variation. 8. ripple voltage less than 3% rms without battery connected. 9. efficiency more than 80% at full load 10. protections (a) input side ac input mccb & elbs with input on/off switch and fuses, contactor (b) output side dc output mccb with output on/off switch and fuses. (c) protection current limit protection, soft start feature, surge suppressor. fast semiconductor fuses for rectifierbridge. (d) control circuit fuses (e) capacitor circuit rectifier hrc fuses. (f) over-voltage cut-back (g) charger over load / short circuit (h) blocking diode 11. controls and switches followings controls and switches are provided in the system 1 ac input source mccbs with interlocking 2 dc output mccb 3 auto/manual float/boost mode selector switch. 4 float and boost voltage variable potentiometers. 5 manual voltage adjustment potentiometer 6 test push button 7 reset push button 8 battery current adjustment potentiometers 9 heater s power supply switch 12. features the following features are provided in the systems: 10 soft start on dc side 11 class-f insulation for all magnetic 12 automatic voltage regulation. 13 automatic changeover from float to boost and vice versa based on current, drawn by battery. 14 filter circuit to eliminate ripple. 15 charger current limit 16 separate battery path current limit. 17 built-in auto phase reversal of operation. 13. meters f.c. b.c. (i)input voltmeter (i) common (ii) input ammeter (ii) input ammeter (iii) output voltmeter (iii) output voltmeter (iv) output ammeter (iv) output ammeter. battery volt meter battery ammeter earth leakage ammeter 14. indications phase on lamps (ii) output on lamp a)phase on lamps (ii) output on lamp. (iii) charger on float led (iv)charger on boost led. 15. annunciation with audiovisual alarms. (i) ac input mains failure (ii) input phase failure (iii) ac under voltage iv) input phase failure v) rectifier fuse failure vi) output fuse failure vii) filter fuse failure viii) dc under voltage ix) dc over voltage x) charger trip xi) capacitor fuse fail xii) output mccb tripped xiii) charger over load xiv) earth leakage xv) dc earth fault xvi) alarm supply fuse failure xvii)battery low condition. v) rectifier fuse failure vi) output fuse failure vii) filter fuse failure viii) dc under voltage ix) dc over voltage x) charger trip xi) capacitor fuse fail xii) output mccb tripped. note : all the alarms shall be provided through electronic display cards. audio alarm through buzzer, visual indication through 10 mm leds & alarm ackn. / reset and led provision is through push buttons. 16. operating ambient temperature surrounding the panel 00 to 500 c 17. surrounding the panel relative humidity. 0-95% non-condensing 18. panel (i) protective grade (ii) cooling (iii)paint ip 42 natural air-cooled smoke grey of iss-692 shade a) average winding temperature rise over ambient temperature b) insulation class c) insulation breakdown voltage. as per relevant iss. f 3 kv for 1 min withstand. 19. cables 1100 v
Tender For supply of set of spares for welding machine : (1)mcb; description:32a 3pole c-curve, 415v, with breaking capacity 6 ka similar to make chint nb1-3-32c ; quantity: 150 no's; (2), secondary diodes ; description:forward current (per leg if=150a, per device if=300a), with vr-200v similar to make sir ectifier srud30040ctd3 ; quantity:50 no's; (3),fuse(5a) ; description:glass fuse 5a/30mm ; quantit y:40no's; (4),bridgerectifier; description:100a,1600v three phase bridgerectifier similar to make m ds 100-16 ; quantity:20no's; (5),3 pin socket machine ; description:female socket with square type mounting base of dimension (25.23mmx25.23mm) and outercircular dia for connecting 15.07mm on the base with threading similar present in mogoro make; quantity:10 no's ; (6),3 pin socket torch; d escription:male socket of round type outer circular dia 19.75mm with threading type to fix to female socket similar present in mogoro make ;quantity: 10no's; (7)10 pin socket ; description:male socket of round type outer circular dia 23.04mm with threading type to fix to female socket similar present i n mogoro make; quantity:10 no's (8),igbt ; description:ic(nom)=100a,ic=160a(25 degree centi), v ces=1200v, similar to make semikron skm100gb12t4; quantity:50 no's; (9)output connector; desc ription :connector lug type flat output connector suitable for 400a welding plant with round insulatio n suitable for ador-fontech,mogoro and aimweld machines; quantity:250 no's ; (10), output connecto rs ; description: welding cable plug connectors. male connectors with current 200a-400a applicable cable standard section 70-95mm square suitable for diffusion and kemppi; quantity:50no's (11), out put connectors ; description: welding cable plug connectors. female connectors with current 200a- 400a applicable cable standard section 70-95mm square suitable for diffusion and kemppi ; quantit y:50no's [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : purchase of three phase 11000/415 v-240 v level 1 (star 1) as per is 1180, 63 kva with crgo/amorphous core substation distribution transformer as per technical specification for year 2025-26 against tender no. ace(p&c)/se(p&c)/ee(p)/ii/e-3015/ 63 kva dist tr/25-26
Tender For snap bidding for rate contract for supply of bis certified energy efficiency level - iii (old)/ level - ii (new), conventional 11/0.433 kv, 200 kva, crgo core distribution transformer
Tender For snap bidding for rate contract for supply of bis certified energy efficiency level - iii (old)/ level - ii (new), conventional 11/0.433 kv, 100 kva, crgo core distribution transformer
Tender For providing and fixing bridgerectifier, module single diode, speed monitor and ceramic porcelain busbar support with related spares at different location under chp-cpp/ppr.
Tender For corrigendum : supply of goods - crgo lamination .27moh grade as percps-bp10987/bp10988for dry type transformer.typical core sheet is attached., crgo lamination m4 grade as percps-aa10905for dry type transformer.typical core sheet is attached., crgo lamination zdkh 90 grade asper cps-bp10985 rev.05.for dry type transformer.typical core sheet is attached.