Web Analytics Made Easy - StatCounter

Building Sale Tenders

Get complete information related to latest Building Sale Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Building Sale Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Building Sale Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42901834 Due date: 09 Dec, 202509 Dec, 2025 NA
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t

CTN :42966070 Due date: 11 Dec, 202511 Dec, 2025 61.63 Lacs
Tender For construction of administration building sale counter and co compost shed for sonepur municipality

State Government

CTN :42756409 Due date: 05 Dec, 202505 Dec, 2025 NA
Tender For purchase of sports exercise physiology lab equipments - wearable physiological monitoring system (01 sensors) (pac), should be able to work in lab and field studies (portable and easy to carry). the system should be able to record the below parameters wirelessly (2 ecg signals, acceleration -3axis, respiration, skintemperature, gsr, spo2, ppg) should have high adc resolution the system should provide real time data recording with online and offline analysis should have at least 8 hours of operation in full transmission mode. option for external battery pack. automatic heartrate variability analysis. online and offline from human subjects. online and offline ecg analysis for all ecg intervals, plots etc. telemetric transmission should be minimum100 meter not less than that. should provide frequency and time domain hrv analysis with automatic plots generation like tachogram plot, rr, histogram plot, delta rr, histogram plot, poincare plot, power spectrum plot etc. the software for recording the data and analysisthe data should be same. four force sensor balance board for body sway analysis that communicate with the same software via bluetooth for analysis and recording. both wireless system and force sensor balance board should work on same software simultaneously and independently for recording and analysis as per user demand. should have software-controlled filtering high pass, low pass filters, ac coupling, digital filters, band pass filter and main filters. display modes: must have simple chart view, scope view, xy view, zoom view, fft, spectrum, averaging view etc. the software should have built in smart analysis features like power spectrum, template matching, curve fitting, cross correlation etc. facility to perform complete heartrate variability analysis (time and frequency domains) online and offline, ecg interpretation, pqrst amplitudes and st elevation, cardiac axis analysis during exercise. cyclic measurement: rate period, frequency, count, minimum, maximum, height, integral, variance, derivatives, arithmetic and mathematic formulae iso and european iec certificates to be provided
 Loading, Please wait...

Connect us via What's Up