Get complete information related to latest Bull Ring Segment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bull Ring Segment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bull Ring Segment Tenders.
Tender For supply of straight polyamide metal thread end fitting thread size pg16 fits to conduit nw17 with he xagonal metric lock nut made of nickel plated brass with suitable o-ring and washer confirming to rds o specn. no. rdso/pe/spec/ac/0138-2009 (rev-1) annex-a, table a-2, sr. no.3. [ warranty period: 30 months after the date of delivery ]
Tender For supply of straight pg metal thread end fitting thread size : pg 21 fits to conduit size nw 23, with he xagonal metric lock nut made of nickel-plated brass, with suitable o-ring and washer as per annexure-a, table a-2, s.no.5 conforming to rdso specn.no. rdso/pe/spec/ac/0138-2009 (rev. 1) [ warranty peri od: 30 months after the date of delivery ]
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For auction sale of miscellaneous steel scrap ms/gi,electrical scrap including various type of light fittings,conveyor belt scrap,grinding roll scrap,scrap ballast-chokes,bullringsegment scrap,machining scrap (chips),air intake scrap filter,old and used lube oils along 210 ltr drum
Tender For design, manufacture, testing and supply of grinding rolls and bullringsegments suitable for bowl mills type xrp-1003 required for ktps-vi stage(1x500mw) and xrp-943 (4x270mw) required for btps stage i and ii.
Tender For corrigendum : supply and fitment of vertical surface insulated grid plates for energy efficient led luminaries and concealed electric al cabling work with occupancy sensors as per specification given below: 1) pvc grid of size 595x595 mm in true horizontal level, s uspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) co nsisting of main "t" runner with suitably spaced joints to get required length and of size 24mm x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "t" of size 24mm x25 mm made of 0.30 mm thick (minimum) she et - 1465 sqft/set 2) occupancy slim pir with requisite accessories - 8 nos/set 3) removal of existing casing capping wiring to conc ealed trench wiring - 40 mtrs/set. 4) white pvc electrical conduit pipes 1 inch - 40 mtrs/set 5) fitment accessories and consumabl es - 1 set. [ warranty period: 12 months after the date of delivery ]
Tender For supply of optical fibre laying for oesc-, 40/33 plb hdpe pipe as per attached specification., optical junction box (compatible with 6 pair ofc) as per attached specification., metal jb (3*3 feet size) as per attached specification., gi conduit (32mm) as per attached specification., layer -2 switch (compatible with 6 pair ofc cable) as per attached specification., media convertor as per attached specification., fiber patch panel/liu with 24 ports loaded as per attached specification., cable tray for 6 pair optical cable size 90*30*30*3(mm) as per attached specification., single mode pigtail fiber cable (sc type) as per attached specification., single mode fiber patch cord (2 mtr. lc-lc type) as per attached specification., single mode fiber patch cord (2 mtr. sc-lc type) as per attached specification., otdr (for fault location) as per attached specification., splicing machine as per attached specification., making trench in hard soil /road cutting to a depth of 300 mm (for laying of gi conduits and cables inside conduits) making trench by digging in hard soil/ road cutting and normalizing the same. hard soil digging of 300mm (w)x 600mm (d), filling of the same with river sand of 50mm, direct burial of armoured cable and hdpe conduit, protecting the cables/conduits using bricks on three sides, covering the bricks with river sand and back filling the remaining portion with the soil to the ground level, wherever the road cutting is made the cables and conduits shall be laid in the 2"/1.5"/1" gi conduit. the top portion of the pit shall be normalized to the ground level with m20 grade pcc (refer annexure-2 laying of ofc cable from unit to oesc for details)., digging (0.5 meter) and the top portion of the pit shall be normalized to the ground level with m20 grade pcc. for finishing this job-related items and manpower are in bidder scope and supplied by bidder in free of cost (refer annexure-2 laying of ofc cable from unit to oesc for details)., laying of 4 pair and 5 pair armoured cable parallelly, in trench and outside trench (as per enclosed scope of work) and instruction as per site in charge. all accessories for cable layout in trench or outside trench are supplied by bidder in free of cost and scope of bidder (refer annexure-2 laying of ofc cable from unit to oesc for details)., ,