Get complete information related to latest Bullet Proof Door Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bullet Proof Door Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bullet Proof Door Tenders.
Tender For corrigendum : supply of drone training node d d -wooden work bench with back panel and electrical fittings , wooden work table with electrical fittings , wooden work almirah with glass doors , oval shapped centre table with electrical fittings , revolving chairs , 3 ton split air conditioner hot and cold , quadcopter drone diy kits , display charts of drones , simulator desktop with remote controllers and vr goggles i7 13th gen , chain link fence around obstacle course 400 x 90 ft , carpeting green turf 400 x 90 ft
Tender For tender for supply of deisgn engineering and supply of electrical instrumentation and civil works : : - design and engineering of imcc panel 2 nos and vfds , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , supply of imcc panels , vfd panels , supply of apfc panels , hvac system , supply of mldb lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material etc , supply of field instruments and necessary piping materials as required , supply of plc , supply lt cables and other related accessories for electrical , termination material and other instrumentation cables as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables ( cable terminations wherever required along with necessary accessories is in the scope of the contractor) for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , substructure excavation , foundation works (footings , columns up to plinth level) , dpc (damp proof course) , and backfilling. , superstructure columns , beams , slabs , brickwork/masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring (tiles , marble) , painting , wall cladding , and other interior/exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring (tiles , marble) , painting , wall cladding , and other interior/exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoing cables
Tender For supply of maintenance assets c c--column corner cl 100 x 100 x 3 point 5mm 2930mm , ceiling support upper r4 2510 mm , cross member 40 x 80 x 2. 6 mm 1505 mm long , cross member with 3 clit 2420 mm long , bunk bed scaffolding 300 x 900 mm , bunk ladder 300 x 900 mm , bunk bed divider 1505 x 900 mm , bed frame upper and lower nut and bolt 10 x 100 mm , gypsum ceiling panel aluminum , flush doors , roof ridge 2440 mm x 600 mm , foundation lock 48 mm x 900 mm , ladder size 1000 x 600 mm , pre painted sheet 900 x 1050 mm , pre painted roof ridge 3040 x 600 mm , foundation bolt 16 mm x 450 mm long , dining table size 8 ft x 3ft , lightening conductor , top frame size 1520 mm , ladder with step , connector clit 45 x 45 x 6 mm , nut and bolt 6 mm x 6 inch long , nut and bolt 12 mm x 75 mm , nut and bolt 12 mm x 75 mm plane head , nut and bolt 12 mm x 150 mm , nut and bolt 10 mm x 20 mm , nut and bolt 12 mm x 45 mm , nut and bolt 12 mm x 140 mm
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . c