Get complete information related to latest Bus Bar Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bus Bar Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bus Bar Conductor Tenders.
Tender For procurement of spares for 22 kw star delta starter panels for tube wells old for palla area re invite - supply of mccb, thermal type, rating 100 a, tp, model no lv510455, make schneider electric., supply of mccb door handle for mccb of rating 100 a, tp, model no lv429338, make schneider electric, supply of aux. contact, 1no + 1nc, model no 29450, make schneider electric, supply of power contactor for main/delta/star (ac3), rating 50 a model no lc1e50m5, make schneider electric, supply of power contactor for phase sequence (ac1), rating 50 a model no lc1e40m5, make schneider electric, supply of over load relay thermal type with base, rating 23-32 a model no lre32 + laeb1, make schneider electric, supply of timer star/delta, rating 230v ac model no laetsd, make schneider electric, supply of protection relay earth fault with cbct, rating 30 ma, model no 17g715kf2 + 17h7nnjn3 , make gic, supply of phase loss + under voltage + over voltage ppr, rating 230 vac, model no mac04d0100 , make gic, supply of phase sequence realy, rating 415 vac, model no mk21d5 , make gic/minilec, supply of auxiliary contactor 2 no + 2 nc , rating 10 a, model cae22m5 , make schneider electric., supply of mcb tp, rating 6 a, model a9n3p06c , make schneider electric., supply of mcb dp, rating 6 a, model a9n2p06c , make schneider electric., supply of mcb dp, rating 2 a, model a9n1p02c , make schneider electric., supply of mcb sp, rating 2 a, model 9000u , make schneider electric., supply of mccb, rating - 50 amp, 50 ka tp, model lv510454 , make schneider electric., contactor for capacitor, rating 10 kvarmake- l&t/epcos., contactor for capacitor, rating 2/1 kvarmake- l&t/epcos., contactor bank , rating 10 kvar heavy dutymake- l&t/epcos., contactor bank , rating 2 kvar heavy dutymake- l&t/epcos., contactor bank , rating 1 kvar heavy dutymake- l&t/epcos., supply of 16 sq. mm single core pvc insulated industrial grade copper conductor ( unsheathed) flexible cable, 1100 volt.make havells/any other approved make., supply of 1 sq. mm single core pvc insulated industrial grade copper conductor ( unsheathed) flexible cable, 1100 volt.make havells/any other approved make.
Tender For corrigendum : tender for supply of equipment design erection tetsing and commissioning for sop to 4g bsnl tower authority by providing single phase lt line at lagga chalga along with augmentation of existing dtr under esd chamba no ii - supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, supply of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, erection of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, mannual carriage of existing & new transf.(25 & 63 kva) 2.00 km back to store, supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96 /24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint
Tender For work of replacement of old damaged twin moose conductor by new twin moose conductor between loc no 144 to loc no 145 in 400kv asoj-kosamba line, approved in r&m plan 2020-21 under achhalia am division and work of repairing in 400kv kosamba-pacham line for damaged y-phase (bottom) conductor between loc527(s) to 530(s) under bharuch division & r-ph conductor between loc 596 to 597 under kim tr division
Tender For auction sale of iron scrap,iron cable drum,empty oil drums,ct & pt combined unit,acsr conductor off sizes (uninsulated),pvc aluminium cable,choke all size,copper,ocb complete,scrap corrugated box,ct off sizes,xlpe cable all sizes,plastic meter box,ignitor,pvc flexible wire all sizes,vcb incomplete,plastic meter seal,scrap plastic (low grade),copper cable scrap,shunt capacitor - off sizes,joint box all size,metering cubical,electric motor of all sizes,ceiling/wall fan,distribution box - ltdst board pwr distr box typ:1 f/100kva,water cooler(e waste),scrap transformer oil with drum(hazardous),scrap transformer oil(hazardous),single phase meter electronic (e-waste),poly phase meter electronic (e-waste),fluoroscent tubes(e-waste),hpsv lamps (e-waste),misc items (refer annexure-1) punjabi bagh,iron - acb body ( refer annexure-2),ring main unit incomplete 3 way (refer annexure-3),ring main unit incomplete 4 way (refer annexure-3),iron (ring main unit) (refer annexure-4),misc items ( refer annexure-5) budella 1
Tender For supply of supply of 3 phase 415v mcc panel 1, iec61439 compliant, floor mounted , installation, testing and commissioning of iec61439 compliant, floor , supply of 3c x 25 sq. mm, stranded copper conductor, xlpe insulated , laying of 3c x 25 sq. mm, stranded copper conductor, xlpe insulated , supply of 3c x 10 sq. mm, stranded copper conductor, xlpe insulated , laying of 3c x 10 sq. mm, stranded copper conductor, xlpe insulated , supply of 4c x 6 sq. mm, stranded copper conductor, xlpe insulated , laying of 4cx6sq. mm, stranded copper conductor, xlpe insulated , supply of 12cx1.5.sq mm, 1.1 kv grade, xlpe insulated, and overall sheathed, , laying and fixing of one number 12cx1.5sqmm pvc insulated and pvc sheathed , supply of indoor end termination with nickel coated brass double compression gland , making of indoor end termination with nickel coated brass double compression gland , supply of 12cx1.5.sq mm size indoor end termination with nickel coated , making of 12cx1.5sqmm size indoor end termination with nickel coated , rerouting of the 3.5cx240sqmm stranded aluminium, xlpe insulated, , supply of 300 mm w x 50 mm d x1.6 mm t size, hot dipped galvanised iron ladder , installation of 300 mm w x 50 mm d x1.6 mm t size, perforated,hot dipped , supply of 150mm w x 50 mm d x1.6 mm t perforated pre galvanised finish , installation of 150mm w x 50 mm d x1.6 mm t perforated pre galvanised finish , supply of 50mm w x 50 mm d x1.6 mm t perforated pre galvanised finish , installation of 50mm w x 50 mm d x1.6 mm t perforated pre galvanised finish , supply of 25 mm x 5 mm gi strip along with g.i. nut, bolt, spring, washer , fixing 25 mm x 5 mm gi strip for earthing on surface or in recess for connections etc , providing of 8 swg dia g.i. wire on surface or in recess for loop earthing , fixing 8 swg dia g.i. wire on surface or in recess for loop earthing , supply of outdoor type junction box having size 630mm x 300mm x 250mm, ms sheet , installation , testing commissioning of outdoor type junction box 630mm x 300mm x 250mm on wall , dismantling and relocating existing mcc panel
Tender For removing, shifting and re-erection the electrical substation equipments from 6th berth s s to proposed location thereof inside cargo jetty area - removing & shifting of the following equipments as per tech spec. no:-1, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit., lt panel ( way-15), re-erection, testing & commissioning of the following equipments as per tech. spec. no. 2, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit, supply at site 3 core armoured ht aluminium conductor xlpe cable of 11 kv grade, following rating of the as per technical specification no. 3 a). 3c x 150. sq. mm., supply at site 4 core armoured lt aluminium conductor xlpe cable of 1.1 kv grade, following rating of the as per technical specification no. 4 a) 3.5c x 300 sq. mm., supply, installation testing & commissioning at site of following 11-way lt load point panel (as per proven design) as per technical specification no. 511 ways {2 i/c, i changeover (bus coupler), 8 o/g}., laying ht/lt armoured aluminium conductor cable 3.5/4 core up to 35 sq. mm. to 150 sq. mm. as per technical specification no. 6, through hdd, with hdpe heavy duty pipe., in existing rcc trench, hard & soft soil, supply at site following way lt distribution panel (as per proven design) as per technical specification no. 715 ways (2 i/c, 1 bus coupler, 12 o/g)., installation, testing & commissioning of lt distribution panel as per technical specification no. 8, providing & connecting following type of earth wire from earth station to equipment as per requirement as per tech. spec. no. 9, 25 x 3 mm. copper strip, 25 x 3 mm. hot dip gi strip., 8 swg gi earthing wire, supply & preparation of earthing station, tfc, chemical treated back filled compound earthing system as per technical specification no. 10a) pipe-in-pipe 50-60 mm. dia. gi type 3 mtr. depth, for transformer body earth, maintenance free, supply of 3 phase 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 11, installation, testing & commissioning of 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 12, supply of tpn double door ip 42 db 4 ways distribution board as per technical specification no. 13, fixing of tpn double door ip 42 db 4 ways distribution board as per technical specification no. 14, supply of following type of mcb as per technical specification no. 15, 40a tpn mcb with 10ka breaking capacity, 32a sp mcb with 10ka breaking capacity, fixing of tpn/sp mcbs with 10 ka breaking capacity as per technical specification no. 16, providing & fixing of surface wiring with 2 x 2.5 sq. mm. copper conductor with pvc insulated (single phase and neutral) for single phase sub-circuit from the db/mcbs to the switch board as per technical specification no. 17, providing and fixing surface wiring with 1.5 sq. mm. copper conductor for light /tube point with pvc insulated single core standard copper conductor wire as per technical specification no. 17, providing and fixing surface wiring for 20a & 10a, 240 volt, 50hz power point as per technical specification no. 19, supply & installation of surface mounted 20 watt led tube light luminary complete with batten as per technical specification no. 20, supply at site 300mm sweep exhaust fan as per technical specification no. 21, fixing of 300mm sweep exhaust fan as per technical specification no. 22, supply of heat shrink straight through joint kit for 11kv, 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 23, fixing the heat shrink straight through joint kit for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no.24, supply of heat shrink long sleeve & boat, suitable for rmu end termination kit (indoor type) for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 25, fixing of heat shrink long sleeve & boat, suitable
Tender For supply and installation of led street light fittings and drawing of acsr conductor for street phase at the different area of ispat pally under ward no- 04 of d.m.c.
Tender For corrigendum : supply of copper conductor, main switch and other electrical materials at contai (a-m) sub-divisional store under tamluk (a-m) division under non-plan programme 2024 - 2025. - 63 amps ac tpn sheet metal enclosed rewireable type fuse main switch 415 volts 3 phase 50 cycles ac supply conforming to is 60947, 32 amp ac tpn sheet metal enclosed re-wireable type fuse, main switch, 415 vlts, 3 phase, 50 cycles ac supply confirming to is 13947(part-3) 1993., fuse wire for 63 amps. as per sample., 20 swg tinned copper fuse wire -32 amp. as per sample., 10 sq mm. 3 core flexible copper conductor (flexible) pvc/xlpe insulated heavy duty industrial (sheathed), 1100 volts grade for earthing of electric installation on barge.conforming to is; 1554 ( part i & ii) & is : 7098 (part i & ii) isi marked., 3core x2.5 sq.mm copper cable (flexible) pvc/xlpe insulated heavy duty industrial (sheathed), 1100 volts grade.conforming to is; 1554 ( part i & ii) & is : 7098 (part i & ii) isi marked. make: havells/ finolex/ polycab& equivalent reputed makes., voltmeter (0-500 volt) (as per sample), magnetic no volt coil (dry type) make bmc (as per sample), magnetic over load relay 28-35 amp for make- bmc starter (as per sample), terminal plate with 6 nos bolts ,12 nos nut and washer(20hp kirlosker motor) (as per sample), gi earthing rod(20 swg ) (as per sample), gi earthing wire (10 swg)(as per sample), pvc insulated1.5 sqm single core copper wire- 1.1kv , isi marked as per is694, fr grade, line analog electic tester 6. as per sample., 15 amp male plug (as per sample), 15 amp. female plug (as per sample), bulb holder (as per sample), 9 watt- white led bulb (as per sample), 18 watt - white led bulb (as per sample), flexible electric wire 2 core pvc coated any make brand. as per sample., pvc insulation tape- 1.80cm x 9m x 0.125 mm make: steelgrip. as per sample., electrical plier with wire cutter any make brand (as per sample), wooden pannel board (6x 4x1 " 2) with coat of panting of app.quality (as per sample), dashpot oil 50ml (as per sample)
Tender For corrigendum : supply of aluminium conductor, main switch and other electrical materials at contai (a-m) sub-divisional store under tamluk (a-m) division under non-plan programme 2024 - 2025. - 200 amp main switch. ac tpn sfu in ss enclosure with 3 nos. hrc fuse links bolted type, 415 v, 3 phase, 50cycles a.c supply conforming to is: 13947 (part-3)/iec: 60947 (part-3) is : 13703 ( part i & ii)/ iec 60269-1&2make: havells/seimens/l&t or gsc equivalent reputed make as directed., 16 amp ac tpn sheet metal enclosed re-wireable type fuse, main switch, 415 vlts, 3 phase, 50 cycles ac supply confirming to is 13947(part-3) 1993., fuse wire for 200 amps, leather hand gloves (11 kv)( as per sample), 3.5 core 50 sqmm aluminium pvc/xlpe insulated (heavy duty industrial) galvanized armored & sheathed heat/sun light resistant & flame/fire retardant , anti-termite & anti rodent electric cable suitable for working upto and including 1100 volts, conforming to is no. 1554 (part-i & ii), 1988/is-7098-i & ii with latest amendements thereof and must have isi certification mark, 3.5 core 25 sqmm aluminium pvc/xlpe insulated (heavy duty industrial) galvanized armored & sheathed heat/sun light resistant & flame/fire retardant , anti-termite & anti rodent electric cable suitable for working upto and including 1100 volts, conforming to is no. 1554 (part-i & ii), 1988/is-7098-i & ii with latest amendements thereof and must have isi certification mark., 16sq mm. 4 core flexible copper conductor (flexible) pvc/xlpe insulated heavy duty industrial (sheathed), 1100 volts grade.conforming to is; 1554 ( part i & ii) & is : 7098 (part i & ii) isi marked., complete power indicator lamp set (red, yellow, green) - led type ,with box , 220volt ,20 ma
Tender For supply of title 1 to 12 - providing, installing, testing and commissioning of silent type diesel generating setcomplying with cpcb iv+ alongwith having prime power rating of 250 kva, 415 volts at 1500rpm, 0.8 lagging power factor at 415v suitable for 50 hz, 3 phase system & for 0.85 loadfactor including credit for dismantle material of old unserviceble dg set and consisting of thefollowings , fabricating, installing, testing & commissioning of automatic mains failure control suitable for250 kva silent type dg set with credit for dismantle material of amf complete with relays,timers, set of cts for metering & protection and energy analyser to indicate currents, phase andline voltages, frequency, power factor, kwh, kvarh & provision for overload, short circuit,earth fault, under frequency, control cabling from amf panel to diesel engine and elsewhere ifrequired, all complete and interlocking including the followin , supplying and fixing exhaust gas piping of suitable dia. welded black ms, b class pipeconforming to is:3589 cut to required lengths and installed with necessary bends, supports andclamps, anti-vibration mountings, insulation of exhaust system with mineral wool/rockwool, 50mm thick wiremesh & aluminum cladding etc., as required as per specification , supply and laying of of 3.5 x 185 sq mm sizes of xlpe insulated pvc sheathed aluminiumconductor armoured power cable of 1.1 kv grade confirming to is:7098 (part 1) includingmaking connection with suitable size of aluminum lugs, laying on wall/surface, testing etc. asrequired. , supply, installation, commissioning & testing of complete set of maintenance free chemicalearthing with copper bonded electrode suitable dia & length 50 x 6 mm pure copper internalstrip with suitable terminal, ground enhancement material / back fill compound / groundingcompound of permanent & maintenance free nature. (50 kg. for each earth pit) , providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. asrequired. , sitc of clean agent based tube fire suppression system 2 kg 10 mtr. heat sensing ul listedtube with ul listed fk5-1-12 clean agent gas , supply & laying of 10 core x 2.5 sq mm copper conductor control cable of insulation:-xlpe(cross linked polyethylene / pvc), inner sheath:- pvc (polyvinyl chloride) st-2 / frls,armouring:- galvanized steel flat strip or round wire, outer sheath:-pvc (polyvinyl chloride)st-2 / frls i/c making connection, testing, laying on wall/surface & commisioning etc completeas required , supply & laying of 3 core x 2.5 sq mm copper conductor control cable of insulation:-xlpe(cross linked polyethylene / pvc), inner sheath:- pvc (polyvinyl chloride) st-2 / frls,armouring:- galvanized steel flat strip or round wire, outer sheath:-pvc (polyvinyl chloride)st-2 / frls i/c making connection, testing, laying on wall/surface & commisioning etc completeas required , supplying and making end termination of size 3 x 185 sq. mm (57mm) with brass compressiongland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpealuminium conductor cable of 1.1 kv grade as required. , 1 supply installation testing and commissioning of avm pads ecs 25x400 suitable for dg set. 1 , supply of high speed diesel for operation of dg set i/c cartage filling etc. complete as require