Web Analytics Made Easy - StatCounter

Bus Bar Spacer Tenders

Get complete information related to latest Bus Bar Spacer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bus Bar Spacer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bus Bar Spacer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :36184454 Due date: 10 Jun, 202410 Jun, 2024 1.14 Crore
Tender For supply, installation, testing and commissioning of horizontal centrifugal axially split case pump with suitable motor an frame and starter cum control panel with mandatory spares and pipeline with accessories an bus bar chamber with main switch

CTN :36269510 Due date: 14 Jun, 202414 Jun, 2024 NA
Tender For rate contract for supply of spares-minor stores andp-equipment-hardware items required from time to time for day to day operation- maintenance-construction of distribution power network of electric division-iii jammu during the financial year 2024-25 - 11 kv disc fittings g.i heavy duty b&s, 11 kv disc fittings g.i heavy duty t&c, 11 kv disc insulator porcelain b&s 45 kn (conforming isi standards), 11 kv disc insulator porcelain b&s 70 kn (conforming isi standards), 11 kv disc insulator porcelain t&c 45 kn (conforming isi standards), 11 kv disc insulator porcelain t&c 70 kn (conforming isi standards), 11 kv drop out set heavy duty, 11 kv hg set (heavy duty), 11 kv la set porcelain (line type) (heavy duty) (conforming isi standards), 11 kv la set porcelain (station type) (heavy duty) 10 ka (conforming isi standards), 11 kv la set porcelain (station type) (heavy duty) 5 ka (conforming isi standards), 11 kv link operating rod (made of fibre glass 30 mm dia, 18 length, with 1 mtr 12 kv insulated handling portion), 11 kv link set 16 size 50x6mmx420mm, 11 kv pin insulator porcelain 10 kn (conforming isi standards), 11 kv pin insulator porcelain 5 kn (conforming isi standards), 11 mtr long s.t pole (st-410, sp-56), 110 w led street light (make : syska / bajaj / havells / crompton / any other reputed company make), 11kv disc insulator (polymeric) 45kn, t&c/b&s (conforming isi standards), 11kv la set line type polymeric (conforming isi standards), 11kv la set station type polymeric (conforming isi standards), 11kv pin insulator with pin (polymeric) (conforming isi standards), 120 w led high mast light (make : syska / bajaj / havells / crompton / any other reputed company make), 140 w led high mast light (make : syska / bajaj / havells / crompton / any other reputed company make), 3-phase, 3 wire trivector meter (secure make), prodigy meter (secure make), ct-pt combine unit with trivector meter, ct-pt combine unit, al. jointing sleeves, al. thimble 120 mm heavy duty (conforming isi standards), al. thimble 185 mm heavy duty (conforming isi standards), al. thimble 300 mm heavy duty (conforming isi standards), al. thimble 400 mm heavy duty (conforming isi standards), al. thimble 630 mm heavy duty (conforming isi standards), al. thimble 95 mm heavy duty (conforming isi standards), aluminium brazing rod, aluminium folding ladder 20 long, aluminium lugs 16 mm2, aluminium paint, angle iron 40x40x5mm, angle iron 40x40x6mm, angle iron 50x50x6mm, angle iron cutter with 3-phase motor, anti climbing device, back clamp for pcc pole/st pole, bamboo ladder 20 long, bamboo ladder 10 long, bamboo ladder 15 long, bimetallic clamp (ht), bimetallic clamp (lt), bus bar insulator (conforming isi standards), chain block of capacity (1 mt), chain block of capacity (2 mt), chain block of capacity (5 mt), chain link fencing 6-0", change over switch (400 amp) (heavy duty) (conforming isi standards), change over switch (100 amp) (heavy duty) (conforming isi standards), change over switch (200 amp) (heavy duty) (conforming isi standards), change over switch (63 amp) (heavy duty) (conforming isi standards), channel iron x-arms 100x50x50x6mm (ismc), channel iron x-arms 75x40x40x6mm (ismc), clamp tester (waco make), come along/rachet, crimping tool hydraulic (with dies 50 mmsq, 95 mm sq, 120 mm sq, 185 mm sq, 300 mm sq , 400 mm sq & 630 mm sq) of standard company conformin to is standard, cutter blade, digital clamp tester/meter (0-1000 amp) ac/dc motwani make, drill bit 16mm (heavy duty), drill bit 20mm ( heavy duty), drilling machine with 3-phase motor and stand (heavy duty), earth tester (waco make), internet energy meter (net meter), flat iron 40x6mm, flat iron 40x5mm, flat iron 50x6 mm, g.i flat 25x3 mm, g.i. wire (8 swg), meter seals, 11 kv go ab switch comp with pipe 5 mtr & operating handle, (3-phase, 3-pole, 200 amp vertical type), guy insulator lt/ht (conforming isi standards), hand gloves rubber insulation level 1.1 k

Central Government/Public Sector

CTN :36253249 Due date: 19 Jun, 202419 Jun, 2024 NA
Tender For supply of dsl bus bar system spares for rtg cranes red or orange colour pvc insulated 400a dsl shrouded busbar, black or blue colour pvc insulated 400a dsl shrouded busbar, green colour pvc insulated 400a dsl shrouded busbar, copper 250a current collector assembly, aluminium end cap for 400a dsl busbar, plastic or rubber end cap cover for 400a dsl busbar, plastic cover joint clamp for 400a dsl busbar, aluminium joint clamp for 400a dsl busbar, plastic anchor clamp for 400a dsl busbar, aluminium end power feed for 400a dsl busbar, plastic or rubber end feed cover for 400a dsl busbar

CTN :36216087 Due date: 17 Jun, 202417 Jun, 2024 NA
Tender For supply, installation, testing & commissioning of set of indoor type vcb panel of 22 nos (06 nos i ncoming, 15 nos outgoing and 01 nos bus coupler) as per enclosed "cee/grc's specification no.- el/con/33 /11/6.6kv/6 kvvacuum-cb/1/2015", rated voltage 12kv, normal current 1250 amps, rated short circuit brea king current ( aginst clause 1.3 of annexure a of referred specification) shall be 40 ka. impulse test voltage (pea k) of 75kv and power frequency test voltage of 28kv (rms) shall be applicable in clause 1.6 of annexure a of ref erred specification. the enclosure shall provide at least the degree of protection ip 53. the oem's type test certif icate of switchgear for extended mechanical endurance class m2 and extended electrical endurance class e2 as per iec 62271-100 are to be furnished along with supply of materials. vcb panels shall be provided with a com mon bus bar set of 2 bars of size 100mmx12mm per phase. busbars will be made out of electrolytic copper of 9 9.9% purity. cts, pts and all other accessories shall be provided as per clause 4.2 to 4.4 of annexure a of referr ed specification. tri-vector meter, ammeter and voltmeter mentioned in clause 4.4 shall have digital display and shall be of modbus rs 485 port, accuracy class 0.5s as per is 15959 latest, power supply -230v ac. microproc essor based numerical protection relay, in addition to clause 4.4 & 6.2 under annexure-a, shall have 4 nos. selec table idmt curves for current-time characteristics. it shall have lcd display to display settings, trip records and also real time & date. it shall record 30 trip records with time and date & shall be provided with modbus rs485 po rt to communicate trip records and protection setting. battery charger and battery under clause 5.0 of annexure a of referred specification will not be required and is not covered under scope of supply. cable glands of stainles s steel are to be provided for all the cable entry holes, cable glands will be suitable for entry of cable and terminati on of armor of cable. cable entry for shall be from bottom only and for this- removable gland plate of thickness 3 mm (minimum) shall be provided as per drawing approval. 44 nos. of insulating mats of class b type conformin g to is 15652 latest, 1.5m (minimum) length & width are to be provided. 02 nos. earthing terminals are to be provi ded on each panel. all fasteners shall be of stainless steel. all meters, indication lamp shall have individual name plate on the front panel. necessary spares should be supplied as per attached annexure -c. the technical data sheet (annexure-b) must be submitted duly filled by the tenderers. work involves removal of existing sf6 & vc b panel including civil work as per annexure-ii. removed vcbs shall be shifted to place as directed by the consi gnee within 1 km. the price shall include transportation of vcb panel to the work site including all loadings and u nloadings without causing any damage of materials. designs/ drawings shall be submitted as per clause 5.1 to 5 .6 of referred specification and also the following for approval of dy.cee/ws /kgpws. a) technical data sheet b ) fully dimensional general arrangement drawing complete with plan, elevation and sectional views, location of ca ble entry for incoming and outgoing feeders. c) complete bill of material clearly indicating nos., rating, make, mod el no etc. of all components/ subassemblies/bought-outs etc. d) foundation drawing and cable entry details. e) s chematic wiring diagrams for all power, control, protection and indication circuits. f) manufacturers' catalogue/ tec hnical literature etc. for numerical relays and other bought-out items. tc & gc as per irs terms & conditions sh ould be supplied along with the material. [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up