Get complete information related to latest Bus Bar Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bus Bar Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bus Bar Spares Tenders.
Tender For supply of spares for nflp auto transformer starter - emergency push button switch (q3) , isolator 200 amps. 6.6 kv on off , part no- ht-100a or equivalent for nflp transformer starter. , p.t. 80va pri 0-110v-230v, sec 0 -12v,part no- ht-206b or equivalent for nflp transformer starter. , auxilary contractor 3no plus 1nc, 110v ,part no- ht208 or equivalent for nflp transformer starter. , resin cast p.t.200va-ph 6.6 kv-110v 3ph, part no- ht300d or equivalent for nflp transformer starter. , resin cast moulded cbct 6.6 kv,part no- ht500a or equivalent for nflp transformer starter. , ct resin cast mldd 100-5, 6.6 kv f-o-l s-c,part no- ht600a or equivalent for nflp transformer starter. , ct resin cast mldd, 150-5 6.6 kv f-o-l s- c,part no- ht650a or equivalent for nflp transformer starter. , ammeter 96 sq mm,part noht1000a or equivalent for nflp transformer starter. , voltmeter 96 sq mm, part no- ht1100a or equivalent for nflp transformer starter. , hrc fuse link for control,part no- ht1201 or equivalent for nflp transformer starter. , push button with element for start sto,part no- ht1300 or equivalent for nflp transformer starter. , lamp holder with lamp on-off-trip, part no- ht1400 or equivalent for nflp transformer starter. , copper busbar 400 amps, 6.6 kv set of,part no- ht101a or equivalent for nflp transformer starter.
Tender For corrigendum : the work of supply & erection/installation of tail less unit, d.o. fuse set, boots and sleeves & diffrent types of material use in dtr protection (bp 2024-25 phase-ii) edd i & edd (rural) kasganj under the juridiction of edc, kasganj on semi turn-key basis. - supply of material by the contractor, do fuse set, m.s. top channel (125x65x2240 mm.), holding clamps for ms top channel, tail less unit 500a/650v with fitting suitable for pcc/stp pole., nut, bolt & washer, m.s. angel with clamp and nut & bolt, m.s. earthing with earth rod as per respo norms, boots & sleeves, al lugs 120 sq.mm, distribution panel box no.2 circuit with stud type tail less unit 500 amp, 650 v with brass holding studs, copper contacts, height of tail less unit 48 inch width 3 inch and pannel size h-1650+300 mm, w-750 mm, d-520 mm & thickness of crca sheet gauge 14x16 along with alu busbar of size 50x6 mm for phases & neutral with color code heat shrink sleeve and mounting stand of 40x40x5 mm ms angle with earthing arrangement., distribution panel box no.3 circuit with stud type tail less unit 500 amp, 650 v with brass holding studs, copper contacts, height of tail less unit 48 inch width 3 inch and pannel size h-1650+300 mm, w-1400 mm, d-520 mm & thickness of crca sheet gauge 14x16 along with alu busbar of size 50x6 mm for phases & neutral with color code heat shrink sleeve and mounting stand of 40x40x5 mm ms angle with earthing arrangement., safe carriage of following/ any other material from electricity store center soron/etah/aligarh to pit site of work from the kaccha & pakka road including loading & unloading at the respective ends including the cost of arrangement of labour, t&p etc. which required for topper completion of work., lt xlpe cable al. 1x120 sq.mm., acsr weasel conductor for jumpering, erection of material, erecetion/installation of d.o. fuse set, fixing of m.s. top channel (125x65x2240 mm.) with all accessories., foundation of distribution panel box no.2 circuitwith fixing arrangement & replacement of cable with lugs., foundation of distribution panel box no.3 circuitwith fixing arrangement & replacement of cable with lugs., fixing of tail less unit 500a/650v with fitting suitable arrangement like busbar etc. for pcc/stp pole., erection of m.s. earthing with earth rod as per respo norms.
Tender For s/i of additional safety items for krishi radio station at main campus shalimar, skuast-k.(capex) - fire detection & alarm system, supplying, installation, testing & commissioning sector control panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per is:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required., 4 zone, supplying, installation, testing & commissioning of heat detector each operating at 54 c/57 c with rate of rise cum fixed tempreature (dual thermistor) type with mounting base complete with all connection etc. as required., supplying, installation, testing & commissioning of smoke detector each with builtin led and mounting base complete with all connections etc. as required., supplying, installation, testing & commissioning of manual call each boxes of ms construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as recuired, supplying, installation, testing & commissioning response indicator each on surface/recess ms box having two leds metallic cover complete with all connections etc. as required., supplying, installation, testing & commissioning fire alarm sounder each with facility to make announcement, mounted in a.b.s. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required., supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with p.t.t. knob & speaker/microphone enclosed in a m.s.(16 swg)/ abs box with break glass in front etc. complete as required., supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000v rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable ethylene propylene rubber (epr) insulation and lszh inner bedding, steel wire armouring & lszh outer sheath complete as required., supplying and fixing of co2 type fire extinguisher isi marked confirming to is: 15683 capacity 4.5 kg complete with delivery hose horn, squeeze grip release valve , locking arrangement, operation manual, bracket with two screw and sleeve including transportation cartage upto various post in kashmir region of sib as per anexure attached etc complete as required. (make : life guard/minimax/safeguard), providing and fixing abc type (dry power type ) extinguisher as per is: 15683 consisting of welded ms cylindrical body, with discharge hose, discharge valve, suspension bracket, initial filling, pressure gauge including transportation cartage upto various post in kashmir region of sib as per anexureattached.etc complete as required. (make : life guard/minimax/safeguard), capacity 6 kg., fabrication, supply, installation, testing & commissioning of indoor type compartmentalized feeder pillar having front area not less than 0.60 sqmtr (900 mm x 900 mm) and depth 45 cm (ns) made out of 2mm thick crca sheet with tappered roof having separate cable and busbar alley, 1 door arrangement i/c locking arrangement, having 400 amp four pole aluminium busbar of full length with base frame made out of 50mmx50mmx6mm (thick) angle iron having 80cm legs for erection in ground with construction of cement concrete suitable foundation size complete with connections and interconnections with copper conductor pvc insulated cables/ insulated aluminium busbar strips of appropriate size and terminal blocks (on outgoing) including supplying & fixing following switchgears & accessories there in, powder coating, labelling, earthing etc. complete as required. providing and fixing following accessories in existing cubical panel board i/c making connection etc. as reqd.details as under panel powder coated 2.0mm mccb 160 a 4p 50ka , ther
Tender For supply of lighting materials for colony, vip and adm. office, plant lighting, cpem and switch yard maintenance work. - single pole mcb - 20 amp, single pole mcb - 40 amp b type, mcb 2 pole 20 amp,l 43220 ro, 40 amp mcb dp switch, m.c.b.isi markd 63a, 240/415v 4 pole, ceiling fan capacitor, self fusing rubber tape black , class b , 31 kv die electric strength , size 2.5 cm x 10 mtr., switch socket combined 6 and 16 amp.anchor make, led tube light 4 ft long,20 watt, copper flexible wire 3 cx2.5 sqmm ,1.1 kv, 4 -core 2.5 sq.mm copper pvc cable 660 v, 3 cx1.5 sqmm flexible copper conductor 1100 v, multistrend copper flexible wire 1 core x 4.0 mm2, (7 strendes) pvc (double) insulated, without armourr, 1.1kv grade (100m/coil), multistrend copper flexible wire 1 core x 6.0 mm2, (7 strendes) pvc (double) insulated, without armourr, 1.1kv grade (100m/coil), hrc fuse 63 amp.type nh00 b.l.make, c and s make,hrc link - 250a, cat no.: csdfl1 250, hrc fuse gear 200 amp. with s.c. breaking capacity 120 ka, 63 amp fuse base with base busbar (black), fuse fitting type sm 63h for 63 amp, 500v ac hrc fuse ee make, hrc fuse 160 amp for one to one replacement of siemense make din type 500v ac s.c. breaking capacity 120ka size-00 rating 160 amp type: 3na3 836- 7y, siemens make fuse base ( din) 160 a rated type 3 nh 3 -032 ( plug in connection at both end), ding dong bell, call bell/ buzzer bell, anchor make 15amp 1way switch new code 4147, plug socket anchor make 16 amp 3pin code 4170
Tender For supply of electrical items - supply and laying of 3.5 core 300 mm2 aluminium cable , making of end connection with gland and socket complete set , supply and fixing of 400 a main switch with out enclosure and with proper socketing , supply and installation of 400 a contractor in one existing switch and one in new switch , supply and intallation of 50 inch x 6 inch copper bar with proper taping in existing busbar , supply and drawing of 25 square mm copper flexible wire. , supply and drawing of 16 square mm copper flexible wire. , supply and installation of 220 a busbar with proper nut bolt washer , making of end connection with socket , supply and installation of 100 a busbar , making of end connection , supply and installation of 100 a mccb with enclosure , 3.5 core 50 square mm aluminium cable , making of inter connection from rising main to busbar and mccb
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar