Get complete information related to latest Bus Trunking Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bus Trunking Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bus Trunking Tenders.
Tender For tender for supply of gis spares of panel - panel connection 1xplug-in size 2 , pre mounted with contact bolt dia 40mm for one phase , screwing material for cb housing and panel connection for one phase , maintenance package 8da/b cb ms gis accessories , spare parts , maintenance package 8da busbar ms gis accessories , spare parts , maintenance package 8da gas monitoring ms gis accessories , spare parts , maintenance package 8da panel connection /cable housing ms gis accessories , spare parts , accessories , spare parts grease barriert a gte 403 3ml , cleaning tissue , lint free , blue 80 pieces/pack
Tender For supply of nflp vcb of 3.3kv with a busbar rating of 400a and ctr- 400/200: 5 , flp vcb of 3.3kv with a busbar rating of 200a and ctr- 200/100: 5 , nflp vcb of 3.3kv with a busbar rating of 400a and ctr- 200/100: 5 , nflp vcb of 3.3kv with a busbar rating of 400a ctr- 100/50: 5 , nflp vcbs of 3.3kv with a busbar rating of 200a and ctr- 200/100: 5 , nflp vcb 3.3 kv switch 100a ctr 100/5 , flp tsu 315 kva, 3.3 kv/550 v , nflp vcb, 3.3kv, 200a, ctr-200/100: 5a , nflp vcbs of 11kv with a busbar rating of 400a, ctr- 200/100: 5 , nflp vcbs of 11kv with a busbar rating of 400a, ctr 100/50: 5 , nflp vcbs of 11kv with a busbar rating of 400a, ctr 60/30: 5 , nflp vcbs of 11kv with a busbar rating of 400a, ctr-400/200/100: 5 , nflp vcbs of 11kv with a busbar rating of 400a ctr 200/100/50: 5 , nflp vcbs of 11kv with a busbar rating of 400a ctr- 400/200: 5, , 1 set of 3 panels (1 incomer of 800a+ 2 outgoing of 400a) 11kv vcb, ctr-25/5, bus bar rating- 1200a , 1 set of 4 panels (1 incomer of 800a+ 3 outgoing of 400a) 11kv vcb, ctr-25/5, bus bar rating-1200a , dgms approved flp vcb 6.6 kv, 400a, ctr 400-200/5-5a , dgms approved flp vcb 6.6 kv, 400a, ctr 300-150/5-5a , dgms approved flp vcb 6.6 kv, 400a, ctr 200-100/5-5a , dgms approved flp vcb 6.6 kv, 400a, ctr 150-75/5-5a
Tender For supply of earth discharge rod assembly for 25kv ac traction to be supplied along with two rail clamps, fiber glass poles of 3 equal length. top clamp (sui table for round/stranded conductor of 10mm to 20mm dia and circular busbar) and cable 9 meters long(7.5m+1.5m) size:248/0.45mm with canvas bag as pe r rdso specification. no: eti/ohe/51(9-87) rev- 1 (oct-92) or latest. material should be supplied as per drawing no.im-107/95 rev 4. [ warranty period: 30 months after the date of delivery ]
Tender For supply of lt distribution panel with 04 nos suitable capacity and size copper busbar arrange ment consisting of 02 nos .4 pole 400 amps mccb for incoming and 01 no. 4 pole 250 amps mccb , 01 no. 4 pole 160 amps mccb , 01 no. 4 pole 125 amps mccb and 02 no. 4 pole 63 amps mcb for out going along with complete wiring , indication lamp , metering arrangement and all accessories as per pcee/cege/ser s pecification no. ser/elec/gs/description /lt panel/1/rev-0/mar 2024, dimension - h x w x d - 1500mm x 1 800mm x 700mm. [ warranty period: 30 months after the date of delivery ]
Tender For supply of electrical materials for the repair and maintenance of street lights as per the boq - t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder, led driver 50w bis certified, led mcpcb plate 50w, led mcpcb plate 100w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply, installation, testing and commissioning of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10 ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply, installation, testing and commissioning of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolyt
Tender For corrigendum : supply and erection package for illumination at ash dyke of ntpc bongaigaon - supply of items, supply of 11 m poles for flood light, supply of 11 mtr gi poles for street lig, supply of foundation bolt set, supply of cable gland of al ar 4cx16 sq., supply of cable gland of al u/a 3.5cx70, supply of cable gland of al u/a 3.5cx240, installation & commissioning works, foundation work of poles & panels, installation & commissioning of light po, direct driven ms rod for earthing, earthing of pole by 25x3 gi flat, under ground laying of power cables, end termination of 240 sq. mm power cabl, end termination of 16 sq. mm power cable, end termination of 70 sq. mm power cable, supply & erection of cable route marker, installation of lighting panels & busbar, letter writing on poles & panels, compliance to safety, compliance to safety
Tender For supply of split air conditioner including green ac, wall mount type (v2) (q2) , supply of 11 kv, 800 amps ht vacuum circuit breaker bus coupler, indoor panel conforming to iec 62271, 200, 25 ka for 3 sec, all as mentioned in specification and as directed , installation, testing and commissioning of 11 kv, 800 amps, ht vacuum circuit breaker, bus coupler indoor panel , supply of ht bustrunking chamber adopter panel of capacity 12 kv 800 amp or nearest higher rating bus bar totally sheet metal enclosed matching with ht panel including busbar , installation, testing and commissioning of ht bustrunking chamber adopter panel of capacity 12 kv 800 amp , shifting of existing 8 nos vcb for installing of bus coupler between existing vcb and connect the bus coupler complete