Web Analytics Made Easy - StatCounter

Busbar Chamber Scrap Tenders

Get complete information related to latest Busbar Chamber Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Busbar Chamber Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Busbar Chamber Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39053351 Due date: 22 Feb, 202522 Feb, 2025 NA
Tender For corrigendum : supply of material code 401800018 vertical busbar/alstan riser r phase aluminium tinned bus bar of 1766 mm and , material code 405000013 vertical busbar/alstan riser y phase aluminium tinned bus bar of 1720 mm and , material code 405000014 vertical busbar/alstan riser b phase aluminium tinned bus bar of 1682 mm and

Central Government And Public Sector

CTN :39075342 Due date: 20 Feb, 202520 Feb, 2025 11.05 Lacs
Tender For corrigendum : supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sens

State Government

CTN :39246362 Due date: 21 Feb, 202521 Feb, 2025 5.00 Lacs
Tender For annual agreement to purchase of different electrical materials as per requirement for maintenance - bulb pin/screw type, 25/40 watts, night lamp, 100 watt, 200 watt, bakalite sheet, 3 mm thick, 6 mm thick, box type tube fittings complete with aluminium polister heavy duty choke, starter, holder duly wired etc but without tube rod., 1x20 watt, 1x40 watt, ball bearing for fan electric motors, bearing number 6201, bearing number 6202, bearing number 6203, bearing number 6204, bearing number 6205, bearing number 6206, bearing number 6207, bearing number 6208, bearing number 6304, bearing number 6305, bearing number 6306, bearing number 6308, bearing number 6309, ball socket, 3/4"(20mm), board teak wood with sunmica top, 4"x4", 7"x4", 6"x8" or 6"x6", 8"x10" for 8"x12", 10"x12", frame teak wood, 4"x4", 7"x4", 6"x8" or 6"x6", 8"x10" for 8"x12", 10"x12", bulkhed fitting water tight suitable for 100 watt lamp aluminium die cost, bush for celling fan, bus bar chamber made of heavy gauge iron sheet complete with copper strips & solter with hinged metallic cover, 32 amps 440 volts 4 way, 63 amps 440 volts 4 way, 100 amps 440 volts 4 way, 200 amps 440 volts 4 way, band pipe of required size & length for service line, choke, aluminium wound 40/20 watt, copper wound 40/20 watt, copper wound 70 watt m.h., copper wound for h p m v lamp 125 watt, copper wound for h p s v/m h lamp 150 watt, copper wound for h p s v/m h lamp 250 watt, copper wound for h p s v/m h lamp 400 watt, electronic choke for t5 28 watt, electronic choke 40/20 watt, call bell, buzzer, ding dong, card less, ceiling rose 3 plate pvc/pb, conduit pipe 16 guage, 20 mm, 25 mm, 32 mm, 40 mm, condute pipe flexibel, 20 mm, 25 mm, conduit band/ eibow deep of surface, 20/25 mm, 32/40 mm, 50 mm, conduit tee / junction box, 20/25 mm, 32/40 mm, 50 mm, capacitor/conduener, 2.5 mfd 440 volt ac, 4.0 mfd 440 volt ac, 6.5 mfd 440 volt ac, for s v lamp fitting 150 watt 20 mfd, for s v lamp fitting 250 watt 33 mfd, for s v lamp fitting 400 watt 42 mfd, for m v lamp fitting 125 watt 8 mfd, capacotor (oil filled), compound water proof (for air coolers & cable), cable xlpe insulated heavy duty 1100 votls grade aluminium stranded/soild condutor unarmoured 2 core weather proof, 6 sq. mm, 10 sq. mm, 16 sq. mm, cable xlpe insulated heavy duty 1100 votls grade aluminium stranded/soild condutor unarmoured 4 core weather proof, 10 sq. mm, 16 sq. mm, 25 sq. mm, 35 sq. mm, 50 sq. mm, 70 sq. mm, 95 sq. mm, cable xlpe insulated heavy duty 1100 votls grade aluminium stranded/soild condutor armoured 3 1/2 core weather proof, 25 sq. mm, 35 sq. mm, 50 sq. mm, 70 sq. mm, 95 sq. mm, 120 sq. mm, 150 sq. mm, c.f.l. lamps pin type, 9 watt, 11 watt, 13 watt, 18 watt, c.f.l. lamps for direct holder, 5 watt, 8/9 watt, 11 watt, 14/15 watt, 18 watt, 20 watt, 23 watt, 65 watt, 85 watt, closser for mcb box, energy meter electronic, single phase, 240 volts, 0-30 amps, three phase 415 volts, 0-30 amps, earth wire / strip, as required size of g.i., as required size of copper, as required size of aluminium, enclouser box sheet steel enclosure (dust product) powder painted d b sleek consumer unit type inclusive bus bar. neutral eart bar etc. complet without isolator single door single phase & neutral, 4 way, 8 way, 12 way, enclouser box sheet steel enclosure (dust product) powder painted d b sleek consumer unit type inclusive bus bar. neutral eart bar etc. complet without isolator single door. three phase & neutral, 4 way, 8 way, 12 way, enclouser box sheet steel enclosure (dust product) powder painted d b sleek consumer unit type inclusive bus bar. neutral eart bar etc. complet without isolator double door.verticalthree phase & neutral vertical type, 4 way, 8 way, 12 way, plug socket d.b.s. spn sheet enclosure (dust product) inclusive of 2 pole and earth metal plug and socket and space to incorporate s p m c b complete without m c b up to 20 amps m c b, flexible wire 3 core, 1.5 sq.mm, 2.5 sq mm., 4.0 sq
 Loading, Please wait...

Connect us via What's Up