Tender For corrigendum : procurement of magnetometer for orv project --magnetometer ,computer acquisition&procesing software,system cables/cable assemblies/connector,peripherals/ associated system,installation material,s & accessories,on board spares,special tools and test equipment ,documentation ,service engineer ,training ,warranty extension charge of 1st year after expiry of initial warranty of 36 months from delivery date. ,warranty extension charge of 2nd year after expiry of initial warranty of 36 months from delivery date. ,
Tender For corrigendum : supply of upgradation of conference cum training studio c c - ceiling speaker , mixing public address amplifier , ceiling microphone , dsp mixer , av controller device , ips panel display size 100 plus minus 2 inch interactive panel , 4k table top document camera cmos sensor , 12 into full hd camera for video conferencing , digital interactive podium , 8 dash port 10 oblique 100 oblique 1000 layer 2 networking switch , providing and fixing of acoustic wall panelling , hdcp compliant hdmi cable oblique hdmi patch cord , installation comma testing comma commissioning, training and documentation charges for complete project along with any other accessories required , 4 years of camc after 3 years of warranty for all items excluding civil works
Tender For corrigendum : supply of refrigeration plant and hvac system and ac plant for grse ars project d d - 590100001001 - supply of ac plant and its accessories , 590100951000 - on board spares for ac plant and system , 590100911000 - instal. and commsng spars_ac plant and accesors , 590100921000 - tool for ac plant and system , 590100271000 - consumables_ac plant and accessories , 590100961000 - documentations for ac system , ser07406 - training_ac plant and system _accessories , ser07407 - ser_instl_stw_hat_sat_ac and sys_ accs , ser07408 - consmbl_prsrvtn and dprsvtn_ac plnt and sys_accs , 590100961001 - submission of bd for ac plant and accs , 590100961002 - ietm documentation for ac plant and accs , 597100001000 - supply of hvac system wth equipment and accs , 597100951000 - obs for hvac system wth equip and accs , 597100911000 - instl and comng spre_hvac sys wth equip and accs , 597100921000 - tools for hvac system and accessories , 597100241000 - consumables_hvac system wth equip and accs , 597100961000 - documentation_hvac system wth equip and accs , ser07409 - training for hvac system wth equip and accs , ser07410 - ser_instl_stw_hat_sat_hvac system and accs , ser07411 - consumable for presrvation and depreservatn , 597100961001 - submission of bd for hvac system and accs , 597100961002 - ietm documentation for hvac system and accs , 597100001001 - suply and erection_hvac ducting wth fitings , 590300000002 - supply of ref plant and sys_its accessories , 590300950002 - obs for refrigeration plant and accessories , 590300910002 - instl and comm spares_ref plant and accessories , 590300920002 - standard tool for ref plant and its acesoris , 590300270002 - consumables_ ref plant and its accessories , 590300960004 - documentation for ref plant and its accs , ser07419 - ser_inst_stw_hat_sat_ref plant and acesoris , ser07420 - ser_preservatn- depreservtn_ref plant and acc , ser07421 - training for ref plant and its accessories , 590300960005 - 1st submisn of bd_ref plant and its acesoris
Tender For corrigendum : supply of cctv system with ai based perimeter surveillance d d - 5mp ir network outdoor ptz camera , 5mp ir network outdoor bullet camera , harware for video management software , video management software as base software with fail over mode , camera licence for vms and fail over , ai suit engine with perpetual camera licence , server for ai suit engine , video recording storage , client work station for control and live view , 11.8 feet x 6.5 feet active led with accessories for live view at gdcc , 55 inch led display unit for live view , 24 port layer 2 gigabit managed poe switch with 4x10g sfp and slot and dual power supply and transreceiver , 8 port layer 2gigabit poe swith with 2x1 g sfp slot and trans receiver , 4 port layer 2gigabit poe swith with 2x1 g sfp slot industrial grade and trans receiver , 6 core single mode armoured opticle fibre cable , 24 port fibre patch panel liu with accessories , 12 port fibre patch panel liu with accessories , 3 meter sc lc opticle fibre patch code , cat 6 4 pair shielded twisted pair cable lszh for outdoor purpose , cat 6 rj 45 stp connector , 24 u floor mount network rack at control room , 9 u wall mount network rack , 6 u pole mount rack for out door purpose , galvanised pole 6 mtr for bullet camera , 5 kva online ups with 30 minutes backup , 3 kva online ups with 30 minutes backup , 1 kva online ups with 30 minutes backup , 3 core 2.5 mm electrical cable , 63 amp mcb with socket box for ups end , 16 amp mcb with socket box for rack end , 50 mm gi conduit for outdoor laying purpose , 25 mm pvc conduit for indoor laying purpose , 50 mm high density polyethylene hdpe pipe , out door camera box , route marker for ofc , lightening ) /bid number : gem/2025/b/6683933 * /dated: 08-10-2025 & & / bid document 1 / 47 & & ' ' /item category arrester , digging and refilling of hard and soft soil concrete bricks , laying of high density polyethylene pipe hdpe underground , laying of gi conduit underground , laying of pvc conduit for indoor laying purpose , laying of optical fibre cable through hdpe gi conduit overhead , laying of cat6 stp through hdpe complete , laying of electrical cable throgh hdpe gi conduit overhead , splicing of optical fibre cores , mounting and fixing of gi pole after excavation of saft hard soil , mounting fixing and dressing of lightening arrestor , mounting and fixing of route marker , mounting fixing and dressing of liu , mounting fixing and dressing of floor standing rack , mounting fixing and dressing of wall mouint rack , mounting fixing and dressing of pole mouint rack , mounting and fixing of all type of cameras , mounting fixing installation and configuration of all type of workstation , mounting fixing installation and configuration of all type of switches , mounting fixing installation and configuration of active led display , mounting fixing installation and configuration of all type of standalone display unit , mounting fixing and dressing of mcb , mounting fixing dressing installation and configuration of ups system , mounting fixing dressing installation and configuration of server hardware , installation and configuration of video management software vms , installation and configuration of ai suit engine , mounting fixing dressing installation and configuration of storage hardware , testing commissioning providing three sets of completion diagram documentation of entire project and training to users //bid details 2 / 47
Tender For corrigendum : tender for supply of power distribution box for mpv project grse yard no 3050 to 3057 e e - pdb(400v fwd mdb)12 way , pdb(400v fwd edb)08 way , pdb(400v aft edb)08 way , pdb(230v fwd mdb)24 way , pdb(230v fwd edb)16 way , pdb(pdb-1)400v , 28 way , pdb(pdb-2)400v , 25 way , pdb(pdb-3)400v , 24 way , pdb(pdb-4)400v , 24 way , pdb(pdb-5)230v , 32 way , pdb(pdb-6)230v , 31 way , pdb(400v gally db)14 way , pdb(230v gally db)24 way , pdb(400v laundry db)12 way , pdb(vdb-1)230v , 16 way , pdb(vdb-2)230v , 23 way , pdb(ndb-1)230v , 24 way , pdb(ndb-2)230v , 26 way , pdb(communication db)230v , 24 way , pdb(230v laundry db)06 way , pdb(workshop db)230v , 08 way , pdb(ecr pdb-1)230v , 20 way , pdb(ecr pdb-2)230v , 17 way , ldb-1(230v) , 10 way , ldb-2(230v) , 13 way , ldb-3(230v) , 22 way , ldb-4(230v) , 24 way , ldb-5(230v) , 25 way , ldb-6(230v) , 16 way , ldb-7(230v) , 13 way , ldb-8(230v) , 12 way , eldb-1(230v) , 15 way , eldb-2(230v) , 21 way , eldb-3(230v) , 20 way , eldb-4(230v) , 7 way , test panel(230v) , 5 way , obs , documentation , installation material , service of engineer , pdb(400v fwd mdb)12 way , pdb(400v fwd edb)08 way , pdb(400v aft edb)08 way , pdb(230v fwd mdb)24 way , pdb(230v fwd edb)16 way , pdb(pdb-1)400v , 28 way , pdb(pdb-2)400v , 25 way , pdb(pdb-3)400v , 24 way , pdb(pdb-4)400v , 24 way , pdb(pdb-5)230v , 32 way , pdb(pdb-6)230v , 31 way , pdb(400v gally db)14 way , pdb(230v gally db)24 way , pdb(400v laundry db)12 way , pdb(vdb-1)230v , 16 way , pdb(vdb-2)230v , 23 way , pdb(ndb-1)230v , 24 way , pdb(ndb-2)230v , 26 way , pdb(communication db)230v , 24 way , pdb(230v laundry db)06 way , pdb(workshop db)230v , 08 way , pdb(ecr pdb-1)230v , 20 way , pdb(ecr pdb-2)230v , 17 way , ldb-1(230v) , 10 way , ldb-2(230v) , 13 way , ldb-3(230v) , 22 way , ldb-4(230v) , 24 way , ldb-5(230v) , 25 way , ldb-6(230v) , 16 way , ldb-7(230v) , 13 way , ldb-8(230v) , 12 way , eldb-1(230v) , 15 way , eldb-2(230v) , 21 way , eldb-3(230v) , 20 way , eldb-4(230v) , 7 way , test panel(230v) , 5 way , obs , documentation , installation material , service of engineer , pdb(400v fwd mdb)12 way , pdb(400v fwd edb)08 way , pdb(400v aft edb)08 way , pdb(230v fwd mdb)24 way , pdb(230v fwd edb)16 way , pdb(pdb-1)400v , 28 way , pdb(pdb-2)400v , 25 way , pdb(pdb-3)400v , 24 way , pdb(pdb-4)400v , 24 way , pdb(pdb-5)230v , 32 way , pdb(pdb-6)230v , 31 way , pdb(400v gally db)14 way , pdb(230v gally db)24 way , pdb(400v laundry db)12 way , pdb(vdb-1)230v , 16 way , pdb(vdb-2)230v , 23 way , pdb(ndb-1)230v , 24 way , pdb(ndb-2)230v , 26 way , pdb(communication db)230v , 24 way , pdb(230v laundry db)06 way , pdb(workshop db)230v , 08 way , pdb(ecr pdb-1)230v , 20 way , pdb(ecr pdb-2)230v , 17 way , ldb-1(230v) , 10 way , ldb-2(230v) , 13 way , ldb-3(230v) , 22 way , ldb-4(230v) , 24 way , ldb-5(230v) , 25 way , ldb-6(230v) , 16 way , ldb-7(230v) , 13 way , ldb-8(230v) , 12 way , eldb-1(230v) , 15 way , eldb-2(230v) , 21 way , eldb-3(230v) , 20 way , eldb-4(230v) , 7 way , test panel(230v) , 5 way , obs , documentation , installation material , service of engineer , pdb(400v fwd mdb)12 way , pdb(400v fwd edb)08 way , pdb(400v aft edb)08 way , pdb(230v fwd mdb)24 way , pdb(230v fwd edb)16 way , pdb(pdb-1)400v , 28 way , pdb(pdb-2)400v , 25 way , pdb(pdb-3)400v , 24 way , pdb(pdb-4)400v , 24 way , pdb(pdb-5)230v , 32 way , pdb(pdb-6)230v , 31 way , pdb(400v gally db)14 way , pdb(230v gally db)24 way , pdb(400v laundry db)12 way , pdb(vdb-1)230v , 16 way , pdb(vdb-2)230v , 23 way , pdb(ndb-1)230v , 24 way , pdb(ndb-2)230v , 26 way , pdb(communication db)230v , 24 way , pdb(230v laundry db)06 way , pdb(workshop db)230v , 08 way , pdb(ecr pdb-1)230v , 20 way , pdb(ecr pdb-2)230v , 17 way , ldb-1(230v) , 10 way , ldb-2(230v) , 13 way , ldb-3(230v) , 22 way , ldb-4(230v) , 24 way , ldb-5(230v) , 25 way , ldb-6(230v) , 16 way , ldb-7(230v) , 13 way , ldb-8(230v) , 12 way , eldb-1(230v) , 15 way , eldb-2(230v) , 21 way , eldb-3(230v) , 2
Tender For bid to ras corrigendum : supply of cisco c111 x8p isr router , sl 118 uc licence for srst , sl 1100 8p app licence for mpls , cisco catalyst c9 200 l 24p 4x switch , 9u rack with pdu and earthing bus , 42u rack with pdu and earthing bus , sm fiber patch cord 10 mtrs , 5 or 6 kva ups system 20 min backup , 2 kva ups system 20 min backup , cat 6 cabling and patching frorn 9u rack to i or o box a and r with conduit , 2 port io box , 24 port utp jack panel , sm 12c amoured optical fiber , hdpe duct 32mm , 12 port liu with lc pc couplers and connectors for termination of 12c ofc , cisco video ip phone uc 8875 , cisco ip phone uc 7841 , 3c 6sq mm frlsh copper wirer cabling from power db to ups with switch and socket with conduits , chemical earth pit with 25 sq mm gi strip and wall mounted gi termination box , grounding of rack and mounted device to earthing termination box with 1c 6 sq mm copper wire with conduit , i and c of 9 u rack with accessories , i and c of 42 u rack woth accessories , i c and basic configuration of cisco c111x 8p isr router , i c and basic configuration of cisco catalyst c9200l , i c and power cabeling for 5 kva ups , i c and power cabeling for 2 kva ups , cabling charges including supply of accessories , termination charges of 2 port io box , i c of 24 port patch panel , fiber laying charges throught under under ground , fiber termination charges and ic of 12 port liu , electrical and earthing works , project management charges for ic of data center with documentation , logistics charges including insurance for material transportation to island
Tender For providing project management consultancy services including supervision, quality assurance, progress monitoring/reporting, measurement, billing and documentation for the work of construction of pre-metric/post metric - hostel buildings for boys & girls at ballari (3 nos.) & siraguppa talukas in ballari district-pkg no. bcwd-1
Tender For providing project management consultancy services including supervision, quality assurance, progress monitoring / reporting, measurement, billing and documentation for the work of construction of pre-metric/post-metric hostel buildings for boys & girls at khustagi,koppal, yalaburga & gangavathi talukas in koppal district-pkg no.bcwd-3