Tender For corrigendum : tender for supply of equipment design erection tetsing and commissioning for sop to 4g bsnl tower authority by providing single phase lt line at lagga chalga along with augmentation of existing dtr under esd chamba no ii - supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, supply of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, erection of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, mannual carriage of existing & new transf.(25 & 63 kva) 2.00 km back to store, supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96 /24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint
Tender For corrigendum : cwek/token-124/864 ews/2024-25 repair/renewal of gi wire earthing for bldg, distribution board, submain wiring and building security light with connected items at various locations under ge 864 ews job no stpp 24-25
Tender For supply of supply of 3 phase 415v mcc panel 1, iec61439 compliant, floor mounted , installation, testing and commissioning of iec61439 compliant, floor , supply of 3c x 25 sq. mm, stranded copper conductor, xlpe insulated , laying of 3c x 25 sq. mm, stranded copper conductor, xlpe insulated , supply of 3c x 10 sq. mm, stranded copper conductor, xlpe insulated , laying of 3c x 10 sq. mm, stranded copper conductor, xlpe insulated , supply of 4c x 6 sq. mm, stranded copper conductor, xlpe insulated , laying of 4cx6sq. mm, stranded copper conductor, xlpe insulated , supply of 12cx1.5.sq mm, 1.1 kv grade, xlpe insulated, and overall sheathed, , laying and fixing of one number 12cx1.5sqmm pvc insulated and pvc sheathed , supply of indoor end termination with nickel coated brass double compression gland , making of indoor end termination with nickel coated brass double compression gland , supply of 12cx1.5.sq mm size indoor end termination with nickel coated , making of 12cx1.5sqmm size indoor end termination with nickel coated , rerouting of the 3.5cx240sqmm stranded aluminium, xlpe insulated, , supply of 300 mm w x 50 mm d x1.6 mm t size, hot dipped galvanised iron ladder , installation of 300 mm w x 50 mm d x1.6 mm t size, perforated,hot dipped , supply of 150mm w x 50 mm d x1.6 mm t perforated pre galvanised finish , installation of 150mm w x 50 mm d x1.6 mm t perforated pre galvanised finish , supply of 50mm w x 50 mm d x1.6 mm t perforated pre galvanised finish , installation of 50mm w x 50 mm d x1.6 mm t perforated pre galvanised finish , supply of 25 mm x 5 mm gi strip along with g.i. nut, bolt, spring, washer , fixing 25 mm x 5 mm gi strip for earthing on surface or in recess for connections etc , providing of 8 swg dia g.i. wire on surface or in recess for loop earthing , fixing 8 swg dia g.i. wire on surface or in recess for loop earthing , supply of outdoor type junction box having size 630mm x 300mm x 250mm, ms sheet , installation , testing commissioning of outdoor type junction box 630mm x 300mm x 250mm on wall , dismantling and relocating existing mcc panel
Tender For bid to ras supply of mcb box four pole cab tree , pvc cable four mm sqr four core havells , pvc wire four mm sqr red , pvc wire four mm sqr black , mcb box forty amp two pole , blank pvc switch board fifteen amp , pvc conder pipe one inch , pvc clip one inch , phase preventer l and t minilec , copper lug fifty mm sqr , copper lug seventy five mm sqr , copper lug sixteen mm sqr , copper lug six mm sqr , pvc getty two inch , pvc getty one poit five inch , screw one point five inch , screw two inch , heat sink sleeve sixteen mm sqr red , heat sink sleeve sixteen mm sqr yellow , heat sink sleeve sixteen mm sqr blue , heat sink sleeve sixteen mm sqr black , pvc flexible pipe one inch black , top anchor sixteen amp , insulation tape length forty m each , t nut bolt one feet , fastner m ten , fastner m eight , cable tie heavy duty eight inch , dol stater twenty amp l and t , earthing reuired resistance less than three ohm , suction valve three inch
Tender For removing, shifting and re-erection the electrical substation equipments from 6th berth s s to proposed location thereof inside cargo jetty area - removing & shifting of the following equipments as per tech spec. no:-1, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit., lt panel ( way-15), re-erection, testing & commissioning of the following equipments as per tech. spec. no. 2, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit, supply at site 3 core armoured ht aluminium conductor xlpe cable of 11 kv grade, following rating of the as per technical specification no. 3 a). 3c x 150. sq. mm., supply at site 4 core armoured lt aluminium conductor xlpe cable of 1.1 kv grade, following rating of the as per technical specification no. 4 a) 3.5c x 300 sq. mm., supply, installation testing & commissioning at site of following 11-way lt load point panel (as per proven design) as per technical specification no. 511 ways {2 i/c, i changeover (bus coupler), 8 o/g}., laying ht/lt armoured aluminium conductor cable 3.5/4 core up to 35 sq. mm. to 150 sq. mm. as per technical specification no. 6, through hdd, with hdpe heavy duty pipe., in existing rcc trench, hard & soft soil, supply at site following way lt distribution panel (as per proven design) as per technical specification no. 715 ways (2 i/c, 1 bus coupler, 12 o/g)., installation, testing & commissioning of lt distribution panel as per technical specification no. 8, providing & connecting following type of earth wire from earth station to equipment as per requirement as per tech. spec. no. 9, 25 x 3 mm. copper strip, 25 x 3 mm. hot dip gi strip., 8 swg gi earthing wire, supply & preparation of earthing station, tfc, chemical treated back filled compound earthing system as per technical specification no. 10a) pipe-in-pipe 50-60 mm. dia. gi type 3 mtr. depth, for transformer body earth, maintenance free, supply of 3 phase 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 11, installation, testing & commissioning of 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 12, supply of tpn double door ip 42 db 4 ways distribution board as per technical specification no. 13, fixing of tpn double door ip 42 db 4 ways distribution board as per technical specification no. 14, supply of following type of mcb as per technical specification no. 15, 40a tpn mcb with 10ka breaking capacity, 32a sp mcb with 10ka breaking capacity, fixing of tpn/sp mcbs with 10 ka breaking capacity as per technical specification no. 16, providing & fixing of surface wiring with 2 x 2.5 sq. mm. copper conductor with pvc insulated (single phase and neutral) for single phase sub-circuit from the db/mcbs to the switch board as per technical specification no. 17, providing and fixing surface wiring with 1.5 sq. mm. copper conductor for light /tube point with pvc insulated single core standard copper conductor wire as per technical specification no. 17, providing and fixing surface wiring for 20a & 10a, 240 volt, 50hz power point as per technical specification no. 19, supply & installation of surface mounted 20 watt led tube light luminary complete with batten as per technical specification no. 20, supply at site 300mm sweep exhaust fan as per technical specification no. 21, fixing of 300mm sweep exhaust fan as per technical specification no. 22, supply of heat shrink straight through joint kit for 11kv, 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 23, fixing the heat shrink straight through joint kit for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no.24, supply of heat shrink long sleeve & boat, suitable for rmu end terminationkit (indoor type) for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 25, fixing of heat shrink long sleeve & boat, suitable
Tender For corrigendum : supply of electrical fencing - single zone energizer , external hootor , ac charger controller unit , battery , lightning diverter kit , fence live light , outdoor console rack , inter mediate posts , corner and end posts , support pole , intermediate post insulators , end strain hooks , end strain insulators , joint clamps , fine pitch wire strainer , ht wire , double insulated cable , warning sign board , earthing , gate top electrification , service fence erection , service post welding , freight and insurance
Tender For corrigendum : supply of copper conductor, main switch and other electrical materials at contai (a-m) sub-divisional store under tamluk (a-m) division under non-plan programme 2024 - 2025. - 63 amps ac tpn sheet metal enclosed rewireable type fuse main switch 415 volts 3 phase 50 cycles ac supply conforming to is 60947, 32 amp ac tpn sheet metal enclosed re-wireable type fuse, main switch, 415 vlts, 3 phase, 50 cycles ac supply confirming to is 13947(part-3) 1993., fuse wire for 63 amps. as per sample., 20 swg tinned copper fuse wire -32 amp. as per sample., 10 sq mm. 3 core flexible copper conductor (flexible) pvc/xlpe insulated heavy duty industrial (sheathed), 1100 volts grade for earthing of electric installation on barge.conforming to is; 1554 ( part i & ii) & is : 7098 (part i & ii) isi marked., 3core x2.5 sq.mm copper cable (flexible) pvc/xlpe insulated heavy duty industrial (sheathed), 1100 volts grade.conforming to is; 1554 ( part i & ii) & is : 7098 (part i & ii) isi marked. make: havells/ finolex/ polycab& equivalent reputed makes., voltmeter (0-500 volt) (as per sample), magnetic no volt coil (dry type) make bmc (as per sample), magnetic over load relay 28-35 amp for make- bmc starter (as per sample), terminal plate with 6 nos bolts ,12 nos nut and washer(20hp kirlosker motor) (as per sample), gi earthing rod(20 swg ) (as per sample), gi earthing wire (10 swg)(as per sample), pvc insulated1.5 sqm single core copper wire- 1.1kv , isi marked as per is694, fr grade, line analog electic tester 6. as per sample., 15 amp male plug (as per sample), 15 amp. female plug (as per sample), bulb holder (as per sample), 9 watt- white led bulb (as per sample), 18 watt - white led bulb (as per sample), flexible electric wire 2 core pvc coated any make brand. as per sample., pvc insulation tape- 1.80cm x 9m x 0.125 mm make: steelgrip. as per sample., electrical plier with wire cutter any make brand (as per sample), wooden pannel board (6x 4x1 " 2) with coat of panting of app.quality (as per sample), dashpot oil 50ml (as per sample)
Tender For complete rewiring of different union offices at nts colony barkakana. - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group b., supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required ., supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required., supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required., wiring for circuit/sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in surface/recessed pvc conduit as required. 2x2.5 sq.mm +1x2.5 sq. mm earth wire., wiring for circuit/sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in surface/recessed pvc conduit as required. 2x4 sq.mm +1x 4 sq. mm earth wire., wiring for circuit/sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in surface/recessed pvc conduit as required. 2x6 sq.mm +1x 6 sq. mm earth wire, supplying and fixing 5 amps to 32 amps rate 240 v c series mcb suitable for inductive load of following poles in the existing mcb db complete with connections testing and commissioning etc as required. single pole., supplying and fixing 5 amps to 32 amps rate 240 v c series mcb suitable for inductive load of following poles in the existing mcb db complete with connections testing and commissioning etc as required. double pole., supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 8 way double door., supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 a "c" curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required., supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required., supplying and fixing brass batten /angle holder including connection etc. as required., supplying, installation, testing and commissioning of following capacity tpn tap off box made of 1.6 mm thick sheet steel enclosure duly painted with power coating on existing rising mains complete with tpn disconnector fus and hrc fuses, connections, earthing etc as required. 32 amp tpn, earthing with copper earth plate 600 mm x 600mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required., providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connection etc. as required., providing and fixing of recessed mounting led round panel light fitting (18 watt)., total impact of gst for the purpose of ctc