Get complete information related to latest Cable Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Laying Tenders.
Tender For supplying installation testing and commissioning of laundry equipment in ashadeep narela delhi - supplying installation testing and commissioning of laundry equipment in ashadeep narela delhi - sitc of front loading washing machine with loading capacity of 30 kg dry weight per charge heavy duty , electrically heater inner basket & outer drum stainless steel, micro countroller base cyclic timer for auto- reserve, auto- timer & auto digital temperature control, water- inlet valve drain valve complete with control panel, & electric motor for wash, driver through pulleys & v- belts and control panel operator on 3ph, 415 v, 50 hz, a.c. supply operation cycle 30 to 40 mintutes complete connection etc as required, sitc of hydro extractor machine direct- driver self- balance with automatic electromangnetic dc injection brake system having capaciy of 30 kg per charge with auto -timed top loading vibration less innner basket and outer drum stainless steel complete with specially designed electric motor and control panel operator on 415 v,3 phase , 50 hz ac supply . operation cycle 5 to 10 mintes complete connection etc as required., sitc of drying tumbler machine front loading open pocket, electrically heater with loading capacity of 30 kg . per charge complete with micro controller base cyclic timer for auto timed & auto - reserver, auto digital temperature control, fitted with control panel , one motor each for driver and blower double walled glass wool insulated outer body mild steel with inner basket stainless steel, self lint screen , v belt driver waster air exhaust etc operates on 415 v, phase 50 hz ac supply . operation cycle 40 to 60 mintes complete connection etc as reqd, supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required.a) 3 x 4 sq. mm, b) 6 x 4 sq. mm, supplying and fixing of following capacity, 240/415 volts, 10ka/15ka c series mcbs suitable for lighting and other loads of following poles in the existing mcb db complete with connection, testing and commissioning etc as reqd.a) 40a, 10 ka , fp mcb (415v), b) 63a, 10 ka , fp mcb (415v), supplying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size complete as required.a) 4x 16 sqmm, b) 4x 25 sqmm, supplying, installation, testing & commissioning of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency >85%, operating voltage ac 140- 270 volt, frequency 50/60 hz, operating temp range -5 c to 40 c, internal surge protection of 2.5 kv with short & open circuit protection, thd 10%, p. f. 0.95, ip20, cri >80, flicker free, (flicker shouldbe below 5 %), life time (led, driver & electrical circuitry), of minimum 50000 burning hours with 70% of initial lumen maintained till life ends, cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 105 120 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). powder coated die cast /extruded aluminium body (thickness > 1.20 mm)a) 40 watt, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in th
Tender For erection work of structures, equipments, earthing, control wiring, cablelaying etc. for 150mva, 220/132kv transformer bay at 400kv veloda s/s under patan tr division.
Tender For supply of supply of hot dip galvanized octagonal street light pole of 7 mtrs length , supply of outdoor type 100w led type flood light luminaire , supply of outdoor type 90w led streetlight luminaire , design, fabrication, supply, installation, testing and commissioning of cubicle type, outdoor type feeder pillar panel , sitc of lt feeder pillar panel , supply power cable of 3. 5 x 50 sq. mm sqmm. , supply of xlpe insulated and pvc sheathed armoured aluminium conductor ug power cable of 4 x 16 sqmm. , supply of xlpe insulated and pvc sheathed armoured aluminium conductor ug power cable of 3. 5 x 300 sqmm. , supply of 50 mm od hdpe pipe of pe 80 pn 6 isi marked , supply of 63 mm od hdpe pipe of pe 80 pn 6 , supply of 110 mm od hdpe pipe of pe 80 pn 6 , supply of underground warning or caution tape size 6 x 250 mtr , supplying and making end termination 3. 5 x 50 sq. mm , supplying and making end termination 4 x 16 sq. mm , supplying and making end termination 3. 5 x 300 sq. mm , excavation for cable trenches in soft soil , laying of upto 63 mm dia size dwc or hdpe pipe , laying of 110 mm dia size dwc or hdpe pipe , laying of cable up to 35 sq. mm in the existing rccor hume or duct or metal or dwc or hdpe pipe as required. , laying of cable above 35 sq. mm and upto 95 sq. mm in the existing rccor hume or duct or metal or dwc or hdpe pipe as required. , laying of cable above 185 sq. mm and upto 400 sq. mm in the existing rccor hume or duct or metal or dwc or hdpe pipe as required. , laying and fixing of cable above 185 sq. mm and upto 400 sq. mm on wall surface , supplying and making of straight through joint with heat shrinkable kit 3. 5 x 300 sq. mm , dismantling bituminous road by manually or mechanical , supply and fixing of single arm bracket having arm length of 1. 2 mtr , supply and fixing of double arm bracket having arm length of 1. 2 mtr , supply of dp mcb, 6 a, c curve , supplying 3 core 1. 5 sqmm of frls pvc round sheathed copper conductor industrial cable , erection of metallic pole upto 7 mtr length including rcc foundation , installation, testing, and commissioning of 90w led type street light fixture , installation, testing, and commissioning of 100w led type flood light fixture , earthing with g. i. earth pipe 4. 5 meter long, 40 mm dia including accessories , providing and fixing 6 swg dia g. i. wire , providing and fixing 25 mm x 5 mm g. i. strip in 40 mm dia g. i. pipe , providing and laying in position cement concrete , dismantling of existing street light poles up to 9 meters , supply and erection of extra supporting ms structure with l channel , laying of caution tape over the cable trench
Tender For annual work contract for cablelaying, termination, jointing, trench excavation work and other related works etc.(as and when required) at chp 3x660mw ktps, koradi.
Tender For supply of sitc of cctv system at kopili ps khps neepco ltd d d - 8 mp intelligent varifocal network camera , 4 mp 32x ir network dome camera , 64 channel network video recorder , joystick for ptz camera control , 8 tb surveillance hard drive , 8 port web managed smart poe switch , l3 switch 16 port , 1000 base lx sfp transceiver module , 75 inch uhd smart display , 15 meters hdmi cable 4k , outdoor cabinet 12u , wallmount 12u 600d , online ups system 6kva , ms rack and irit link for smf batteries , smf battery for 60 minutes 12v 42ah , online ups system 2kva , cat 6 utp cable outdoor cable , cat 6 utp cable unarmoured , ofc cable 12f sm hdpe , patch cord lc 3 meter , optical fibre cable joint closure , fiber drawer liu , patch cord cat 6 utp , pvc conduit pipe casing and crapping , mcv 10 amp with metal box , industrial 2 point 5 copper cable 90 meter , 2 point 5 mm 2 core copper cable , hdpe pipe 32 mm , gi wire for stinging , ss combine 16 amp , round 7m gi pole dia 76mm , optic fibre cable clamp , ofc cable bracket , gi pipe 3 inches , socketweld galvanised elbow 3 inches , installation and commissionig of cctv system , laying of ofc cable , laying of cat cable , erection of gi pole , laying of gi pipe ) /bid number: gem/2026/b/7168435 * /dated: 30-01-2026 & & / bid document1 / 29
Tender For annual rate contract work of ht/lt lines, t/c, maintenance & o/h laying of xlpe cable pole to pole & laying(mandatory), testing & commissioning of 11 kv/22 kv ug xlpe cable of feeders emanating from 66kv palod ss(complex work needs to perform with number of ug utilities and existing dgvcl feeders present in location where cablelaying by open excavation method is also required to protect existing feeders and to attend cable fault and locate the cable fault) for nd and any scheme in the jurisdiction of mota borasara sdn through outsourced agency for existing dgvcl network for sdn under kim division.
Tender For annual rate contract work of ht/lt lines, t/c, maintenance & o/h laying of xlpe cable pole to pole & laying(mandatory), testing & commissioning of 11 kv/22 kv ug xlpe cable of feeders emanating from 66kv mota borasara ss(complex work needs to perform with number of ug utilities and existing dgvcl feeders present in location where cablelaying by open excavation method is also required to protect existing feeders and to attend cable fault and locate the cable fault) for si and any scheme in the jurisdiction of mota borasara sdn through outsourced agency for existing dgvcl network for sdn under kim division.
Tender For annual rate contract work of ht/lt lines, t/c, maintenance & o/h laying of xlpe cable pole to pole & laying(mandatory), testing & commissioning of 11 kv/22 kv ug xlpe cable of feeders emanating from 66kv vadoli ss(complex work needs to perform with number of ug utilities and existing dgvcl feeders present in location where cablelaying by open excavation method is also required to protect existing feeders and to attend cable fault and locate the cable fault) for diss and any scheme in the jurisdiction of kim sdn through outsourced agency for existing dgvcl network for sdn under kim division.