Web Analytics Made Easy - StatCounter

Cable Route Marker Tenders

Get complete information related to latest Cable Route Marker Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Route Marker Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Route Marker Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :38151900 Due date: 23 Dec, 202423 Dec, 2024 20.08 Lacs
Tender For corrigendum : realignment of building service lines sjvn chq building at shanan shimla - providing and fixing 65mm dia g.i. pipes , painting 65 mm g.i. pipes , providing and filling sand of grading zone , re laying of dismantled 65mm g.i. pipes , c class heavy duty 150mm ms pipe is 1239 , c class heavy duty 150mm ms pipe fixing , c class heavy duty 150mm ms pipe is 3589 , 150mm non-return valve , perforated pre-painted m.s. cable trays , m.s. cable trays bends , pvc insulated and pvc sheathed xlpe power cable , gland and aluminium lugs , laying 200mm dia od , masonry chamber , one number pvc insulated and pvc sheathed xlpe power cable , outdoor cable end termination with heat shrinkable jointing kit , cable route marker with cement concrete

State Government

CTN :38564131 Due date: 30 Dec, 202430 Dec, 2024 NA
Tender For building material - store material, cement (is) (rate 50 kg per bag) 43 grade 53 grade ordinary portland cement (opc) ppc-portland pozzolana cement, (is) thermo mechanically treated bars (tmt) mild steel rod (rate per kg) required in 8mm, 10mm, 12mm dia, sand (white sand) (rate per cubic metre) excluding void is: 1542 is: 2166 for using it in construction works, aggregate (rate per cubic metre) excluding void 20 mm nominal size graded stone aggregate 20 mm nominal size graded stone aggregate, hard moorum (rate per cubic metre) excluding void hard muram having cbr> 12%, stone dust (rate per cubic metre) excluding void crusher stone dust, brick (rate per thousand numbers)size (190*90*90 mm) well burnt chimney bricks in bulls pattern trench kiln manufactured by ghol process crushing strength not less than 40 kg/cm to and water absorption not more than 15% , floor tiles (rate per square feet)size 300x300 mm ceramic glazed tiles istiles thickness 6 to 7 mm, wall tiles (rate per square feet)size 300x450 mm ceramic glazed tiles istiles thickness 6 to 7 mm, western commode (rate per each)size 360mmx475mmx395mm anti-germ fluoro-polymer coated water closet european type w. c. pan size 360x475x395 mm with solid poly propelyne made soft closing seat cover., wash basin (rate per each)size- 570mm x 470mm x 190mm all fittings and fixtures, door frame (rate per kg)size 100mm x 50mm x1.6mm profile c of 1.6 mm thick single rebate is 4351 manufactured from commercial mild steel sheet, flush door (rate per metre)size- 1800 mm x 850 mm x 35 mm is marked flush door shutters is: 2202 (part 1) decorative type, core of block board construction with frame 1st class hard wood and well matched teak 3 ply veneering with vertical or cross bands and face veneers on both faces of shutter, gi pipe size- 32 mm dia (rate per meter) is mark g.i. riser pipe as per i.s. 1239 minimum thickness 3.2 mm, gi pipe (rate per metre)size 65 mm dia galvanized iron (ms) pipes is-1239 nominal bore in 65 mm minimum thickness in 3.6 mm, hdpe pipe (rate per metre) size- 50 mm dia hdpe 100is 4984/ 14151/ 12786/ 13488 minimum thickness 3.6 mm, wire (rate per running meter) size- 4.0 sq.mm multi strand submersible flat cable is marked 3 core copper wire, water storage tank pe capacity 500, 1000, 10000 ltr. (rate per nos), socket (rate per nos) size 66 mm dia galvanized iron (ms), elbow (rate per nos) size 66 mm dia galvanized iron (ms), pvc pipe (rate per metre) the oriented un-plasticized polyvinyl chloride pvc-o pipes for potable water supply as per is: 16647-2017 duly inspected and tested and having bis certification mark size (20 mm) dia minimum thickness 2.87 mm size 1 (25 mm) dia minimum thickness 3.38 mm size 1 (40 mm) dia minimum thickness 3.68 mm

Central Government / Public Sector

CTN :38582668 Due date: 06 Jan, 202506 Jan, 2025 NA
Tender For provision of cable route markerfor s&t cable of khurda road division.

State Government

CTN :38497475 Due date: 07 Jan, 202507 Jan, 2025 NA
Tender For for removing of trench cover tracing the defecting cable applying the ht tape and replacement of dmz and defective cable at 400kv ss unnao

State Government

CTN :38485761 Due date: 23 Dec, 202423 Dec, 2024 5.36 Lacs
Tender For construction of 30m long inplant rcc road, replacement of broken cover slabs on cable trench and other tit bit civil works at kotulpur 33/11 kv sub station under bishnupur (d) division, dist. bankura.

Central Government/Public Sector

CTN :38456951 Due date: 26 Dec, 202426 Dec, 2024 25.00 Lacs
Tender For repair/replacement of lt ug cable, lt poles, control panels board, change over switches and allied items at af station naliya under ge(af) naliya - taking out old unserviceable lt cable of any size any type from trench/duct/ poles / roof/pipe etc and keeping aside for segregation of serviceability. serviceable cable will be re-laid at same place or other place as required complete all as specified and directed., supply, laying and connecting xlpe insulated, armoured, heavy duty electric cable multi stranded aluminum conductors, 1100v grade, of size 06 sqmm 2core with proper size of lugs and laid in trenches / ducts / through gi pipe / fixed to poles etc complete all as specified and directed. note: excavation earthwork, cable covers, sand cushioning and gi protection pipe shall be measured and paid separately under relevant item., all as per serial item number 2.00 here-in-before but of size 16 sqmm 4 core., all as per serial item number 2.00 here-in-before but of size 35 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 50 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 70 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 95 sqmm 3.5 core, re-laying of old serviceable cable of any size obtained from item above. note:- excavation earthwork, cable covers, sand cushioning and gi protection pipe shall be measured and paid separately under relevant item., excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in soft/ loose soil, for laying of under ground electric cable, pipes etc complete all as specified and directed. note:-(i) authorised width & depth shall only be excavated, measured and paid as specified in clause 3.2.3 of ssr part ii and 19.74.1 of ssr part i for cable/pipe laying portion.(ii) serviceable pcc /rcc cable cover obtained during excavation shall be stacked separately carefully without any extra cost to the deptt., material and labour for river bed sand filling in trenches/ ducts 15 cm above cable and 8 cm under the cable for cushioning/protection to cable including spreading, leveling and get thick 18cm after hand punning complete all as specified and directed, laying only serviceable un-reinforced precast concrete cable cover class lv, type 1, flat, of 250 mm x 150 mm x 40 mm obtained from trenches, abetting each other with gap between adjacent slab not exceeding 10 mm over under cable for protection complete all as specified and as directed., supply and laying un-reinforced precast concrete cable cover, class lv, type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over under cable for protection complete all as specified and as directed., returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed., removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed., material and labour for cutting under the road /pavement /hard standing or in any other situation with the manual labour for crossing of u/g cable through it and making both the end good complete all as specified and directed ., supply and laying gi water tubing of 80 mm bore, light grade, is-1239 marked with all fittings is marked and laid in trenches/under roads/in drains with suitable size flat iron/gi clamps, bolts, nuts and washers etc for cable protection complete all as specified and directed., supply and laying gi water tubing of 50 mm bore, light grade, is-1239 marked with all fittings is marked and laid in trenches under roads/in drains, fixed to poles/walls with suitable size flat iron/gi clamps, bolts, nuts and washers etc for cable protection, complete all as specified and directed ., supply and laying gi water tubing of

CTN :38363368 Due date: 18 Dec, 202418 Dec, 2024 NA
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar

CTN :38388172 Due date: 18 Dec, 202418 Dec, 2024 NA
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar

Central Government And Public Sector

CTN :38354542 Due date: 18 Dec, 202418 Dec, 2024 93.15 Lacs
Tender For provision of power supply infra items for implementation of leh-chushul-thakung itbp link in ba leh. (rate contract for 06 sites) - sub head-i:- (dg set), supply of diesel engine alternator set suitable to generate 5 kva at site conditions, cpcb-iv, totally enclosed diesel engine of suitable to deliver minimum 8.0 bhp (at ntp) , factory assembled and factory tested single/multi cylinder air / water cooled electric start ready to use (rtu) type, housed in a sound proof canopy with manual control panel and coupled with 5 kva single phase, 230 volts alternator at 1500 / 3000 rpm, 0.8 lagging power factor, h-class insulated winding, mounted on rigid ms sheet channel base-frame of sturdy design with necessary reinforcement and with in-built fuel tank of sheet metal, suitable enough for minimum 8 hours running of dg, complete with drain valve, air vent, inlet, outlet connections and gauge. complete with all accessories, battery, engine control panel and having lube oil pressure meter, fuel level gauge, voltmeter, ammeter, frequency meter, engine rpm meter complete as per specifications attached., supplying , installation, testing and commissioning of maintenance free chemical earth station as per latest rdso specifications consisting of :-a) copper bonded steel electrode of 3 meter long, 17 mm dia with copper bonded thickness of minimum 250 microns and ul listed and marked - 1no.b) maintenance free, environmental friendly, mineral compounds, semi soluble , non corrosive , conductivity improving material of rdso approved- 35 kgc) polyplastic , heavy duty, weatherproof, environmetle free earth pit chamber with cover size approx. top dia 250mm, bottom dia 330 mm and height 260 mm heavy duty of 7 ton load capacity, the base unit should have knockouts for interconnecting of strips- 1no., providing and fixing 32 mm x 3 mm g.i. strip direct in ground including digging the trench, laying of strip and refilling the trench, making good the damages, connections etc. as required., supplying installation, testing and commissioning of 32 a rating, double pole, side handle type changeover switch in sheet steel enclosure suitable for operation on 240 v,1-phase, 50 hz ac supply including interconnections , complete as required (bsnl approved makes)., replacement / supplying & laying of 2 x 6 sq mm pvc insulated, pvc sheathed copper conductor armoured cable of 1.1kv grade on surface/wall i/c making connections, testing etc complete as reqd. (isi make), supplying and fixing of fire bucket set( set of 3 buckets) of 9 litre capacity coloured with fire red paint and written "fire on it including supplying and fixing suitable size ms angle iron frame suitable for 3 buckets having hooks etc. including fixing on wall and filling soft sand in buckets complete as required., supplying and fixing of abc type fire extinguishers of 2 kg (abc powder type map-90) complete with delivery hose, squeeze grip release valve, locking arrangement, pressure gauge, operation manual and bracket complete with installation at site with suitable bracket complete as required (isi), acceptance testing of the 5 kva dg set with initial testing after commissioning of dg set at site for 4 hrs in presence of bsnl representative and final acceptance testing after the initial testing for 8 hours on full load and 1 hour on 10% over load at site as per bsnl a/t performa. all resources (fuel, artificial load arrangement, skilled manpower etc.) required for this acceptance testing shall be arranged by vendor., sub head - ii: ( solar power plant), supplying, installation, testing and commissioning of mono perc solar pv panels for 12.5 kwp solar generation system rating complete as required as per the attached specifications., supplying, installation, testing and commissioning of battery bank of 180 v suitable for 12.5kwp solar pv system comprising of 90 nos.. 2v - 200 ah rating vrla batteries, battery rack, protections, dc distribution board, suitable teflon cabling for interconnections,
 Loading, Please wait...

Connect us via What's Up