Web Analytics Made Easy - StatCounter

Cad Software Tenders

Get complete information related to latest Cad Software Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cad Software Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cad Software Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :42954907 Due date: 18 Dec, 202518 Dec, 2025 17.12 Lacs
Tender For custom bid for services - hiring of support services required for ils installation; 1. the scope of works involves hiring of suv vehicles, jcb, poklane, gas welding machine, dgps, total station etc as per the list of items. 2. construction of earth pit inspection chambers. 3. the services are required during installation of ils at kolhapur airport. 4. the details of services required are as follows: 1 hiring of passenger vehicle with driver 02 nos of suv type vehicle, with air conditioning and driver. should be able to carry 7 persons comfortably (excluding driver). required for total 32 days. 2 provision of 08 numbers of manpower per day 08 nos of manpower (labourers) preferably male to be deployed at site per day for carrying out works. required for total 32 days. 3 provision of crane/hydra with operator with 80 feet boom and at last boom it should have load capacity of 1.5 tonnes required for 10 days as and when required. 4 provision of jcb machine with operator required for carrying out excavation work required for total 10 days as and when required 5 provision of dgps (along with cad software and gps coordinate to cartesian coordinate conversion software) with operator is required for survey work. required for total 3 days as and when required 6 hiring of total station (survey equipment) total station with accessories for surveying with trained surveyor. required for total 6 days as and when required 7 provision of 02 nos of hammer drill machines with operator to be provided with 14,18 and 20 mm drill bits required for 06 days as and when required 8 hiring of gas welding gas welding machine with accessories/consumables and trained welder. required for total 7 days as and when required. 9 hiring of arc welding arc welder machine with accessories/consumables trained welder. required for total 3 days as and when required 10 provision of transport vehicle (small) for transporting materials to work sites. camper type vehicle to be provided required for total 10 days as and when required 11 provision of heavy lorry trucks/ dumper for transporting the materials and goods to the worksite truck lorry and dumper to provided required for total 10 days as and when required 12 hiring of hydraulic machine/poclaine machine with hydraulic driller for digging hard rocks along with trained operator. required for total 8 days as and when required 13 provision of soil compactor with operator for compacting the refilled surfaces, including removal of malba, rocks, levelling the surface, etc. to be provided with operator required for total 4 days as and when required 14 construction of erath pit inspection chamber to be constructed from brick, mortar having smooth cement plaster on exposed walls. the outer dimensions 450mm x450mmx 450mm. the top surface to be flushed with ground and to be covered with suitable fiber cover having load capacity 40 ton..

CTN :42900851 Due date: 04 Dec, 202504 Dec, 2025 1.84 Lacs
Tender For providing of custom bid for services - supply and installation of auto cad software latest version

CTN :42910405 Due date: 08 Dec, 202508 Dec, 2025 NA
Tender For supply of cadence software to electronics department mit college mysuru

State Government

CTN :42756413 Due date: 05 Dec, 202505 Dec, 2025 NA
Tender For purchase of biomechanical equipments - isokinetic dynamometer (pac), should be able to access/test various joints in isolation should be able to meet requirements to test sports personsshould be able to test in different resistance modes such as isokinetic (concentric-concentric, concentric-eccentric , eccentric, concentric , and eccentric-eccentric), isotonic, isometric, and passive protocols should include options for angles, hold-times, rest period, repetitions, and sets. the system should be able to test all the major body segments and joints such as shoulder, forearm, elbow, wrist, hip, knee, and ankle.should have adjustable range of motion stops in full 360 degrees. should have 360-degree rotation for the force arm (connecting dynamometer to the pedal) to have wide range of motionshould be able to accommodate different athletes with varying height and weight with provision for seatbelt harness for better stabilitythe dynamometer or chair should be movable to accommodate different athletes for quick set-up and better usability with locking clamps for securing the system in place for testingshould be able to do gravity correction when the limbs are positioned with the lever arm on the dynamometerthe software should be provided to analyze the raw data and export the raw and processed data in different file formats such as excel, text, etc. the software should provide detailed report for various testing protocols such as individual test for joints, data/graph overlay for comparing pre and post testing, repeatability, progress, multi-session.should be provided with latest compatible workstation/laptop of reputed brand like hp, dell (latest generation) processor, minimum16gb ram, windows os 11, and laser printerconcentric speed: 500 deg/sec or more eccentric speed: 500 deg/sec or more concentric torque: 500 ft-lb (678nm) or more eccentric torque: 500 ft-lb (678 nm) or more isometric torque: 500 ft-lb (678 nm) or more isotonic torque: 500 ft-lb (678 nm) or more isotonic torque as low as .5 ft-lbfeedback formats: roadway, interactive line, interactive path, reaction training, proprioception training, breakout, and pong.torques. time, torques. angle, torque bars, work bars, power bars. it should be possible to use mechanical stops even with custom patterns (important for safety in research)the same attachment should be usable for left and right side of subject for consistencies in data.should be certified and approved by ce/eu medical devices directives or usfda

State Government

CTN :42756414 Due date: 05 Dec, 202505 Dec, 2025 NA
Tender For purchase of sports physiotherapy lab equipments - focused shockwave therapy, the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high power laser thera, it should have class iv laser solid-state it should have inbuilt protocol for different indications laser wavelength should be 808nm & 980nm for 18w it should provide laser power up to 0.500mw to 18w pick power 18w (808 nm wavelength for 8w & 980 nm for 10w) the unit should have 7 touch screen facility for use the unit should operating mode should be cw (continuous) or pulsed the unit supply with attachments: scanning laser applicator 500-550mw (class 3b) the unit supply with small and large attachments 1cm and 5cm should be provided to cover different areas the unit supply with dila (deep intratissue laser adapter) supply 2 pairs of laser protective goggles to be supplied warranty 2-year class iv laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. the class iv deep intratissue laser therapy machine is european ce approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. it is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication cdsceo device registration certificate unit supply with original trolley, combination therapy machine with vaccum, the unit should be 7 colour display with touch panel treatment encyclopaedia electrodiagnostic i/t curve number of built-in programmes 204 number of user programs 150 number of compatible 2 ultrasound heads electrotherapy parmenter 2 channel electrotherapies max constant current inpatients circuit cc mode- 10. galvanic current 40 ma diadynamic, pules, current 60 ma interferential, kotz, current, unipolar sing surge -100ma tens and sp-tens current 140 ma tonolysis 100 ma microcurrents 1000 a max. voltage in patients circuite (cv mode)-140 v treatment timer 30s 60 min. the unit ultrasound head amplitude- max. 8w for 4cm head working in continuous mode the unit ultrasound head max 12w for cm working in pules mode ultrasound therapy parameter operation frequency- ultrasound head with acoustic working frequency of 1mhz & 3.5mhz with the effective radiation area 4cm effective radiating area- 4cm max ultrasound intensity -continuous /pulse mode 2/3w/cm frequency in pules mode- 16 hz/48 hz/100 hz 24. duty factor in pulse mode 5-75%, step 5% thermal effect 2-year warranty ce european or fda usa certified with iso medical device certifications cdsceo device registration certificate unit supply with original trolley and gel bottle stand and vacuum cup stand with electrode, low frequency electro magnetic therapy, 7 colour touchscreen peration mode: program/manual a sensory indicator of the magnetic field activity- magnetic stripes treatments in dual mode setting the frequency range of the magnetic field with an accuracy of 0,01 hz using the on- screen keyboard illustrated encyclopaedia with a de
 Loading, Please wait...

Connect us via What's Up