Tender For strengthening of (e/m) equipments of various tube wells installed at babu park kotla area under kasturba nagar constituency ac-42 . - s/o double flanged g.i pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with g.i flange on both ends having the slot for sub cable.make: - tata/jindal, supply of out door type 7.5 to 10hp hut type electrical feeder pillar/metal board of welded construction of size 1370mm x 760mm x 460mmfabricated with 16 swg m.s. sheet with horizontal and vertical intermediate chamber of suitable size onsuitable size insulating board to make the panel robust, having double door with 14 swg s.s hinges along with double locking arrangement with arrangement for mounting of switch gear and electrical energy meter i/c powder coating, vermin proof having following items.1. mccb 63 amp, 4 pole-1 no2. rccb/elcb 63 amp, 4 pole with earth fault indicator and positive contact indication protecting a circuit automatically 1no3. fully automatic star delta starter of 10hp, 3phase oil immersed type 1no4. digital ampere meter 96mmx96mm square shape of 0-30 amp range 1no5. digital voltmeter of 96mm x 96 mm square shape of 0-500 volt range with selector switch 1no6. led indicating lamps with fitting (a set of 3 lamps) 1set7. shunt capacitor of 5 kvar with three phase isolator 1no8. motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage-low voltage protection. 1no9. programmable time switch (i.e. ryb phase & facility to change over from automatic to manual & vice versa) up to 10 h.p.1no10. complete wiring of panel board & installation of electrical accessories in the panel with required copper conductor wire & thimbling etc.as required. the panel board shall be mounted on the base frame of 600mm height made of 50x50x6mm angle iron frame.make:-all the insert used in panel must be of djb approved makes and should be isi marked where make of that equipment is not approved.djb item code 10.2.1, supply of pvc insulated pvc sheathed copper conductor flat cable size 3 core x 4sq mm,1100 volts, confirming to is 694(each roll 100mtr long) make: finolex / havells./kei/any djb approved make., s/o nut bolts,washer dia 1 long full threaded, s/o rubber packing 50 mm dia. flange., lowering and lifting of sub/sets from bore by taking out double flanged gi pipes, submersible p/set, cable, cutting of rusted nuts and bolts etc and replacement of damaged d/f gi pipes, cable, defective pump set etc as per site requirement and lowering of sub p/set, sub cable, gi pipe etc as required, jointing of cable from sub p/set along with holding of cable with pipes and jointing of d/f pipes etc with nuts bolts and rubber packing etc. the job includes hiring of all t&p, tripod stand, chain pulley block and other material handling equipments, safety gadgets ad required and consumable material (rubber packing and nuts bolts) will be arranged by the firm as per site requirement. the other material required during execution will be provided by department.
Tender For supply, installation, testing and commissioning of automatic power factor correction (apfc) panel including capacitor bank at wtp nagda (275 kvar)
Tender For supply of various electrical consumable items for emd 3 & emd-5 at wtps, gsecl. - jyoti make voltage operated auxiliary relay type re-300, voltage: 220 v dc with 4 c/o contacts without plug in base with optional led indicator, plug in type relay make paramount coil voltage 110 v ac 50 hz., plug in type relay, "paramount" make, coil voltage - 24 v dc, with 2 c/o contacts, type-p3-2-pz-m-24 v dc with led & relay base., plug in type relay, "paramount" make, coil voltage- 240 v dc, with 3 c/o contacts, type-p3-3-fpzi -240 v dc with led & relay base., oks contact cleaner [ 2621 /2 ] size 500 ml [ 275 gms ] spray bottleman u oks speciality lubricants { india } pvt. ltd., wd 40 size 340 gms spray bottle manu hardcastle & waud mfg . co . ltd, crc-226 contact cleaner in 415 ml/300 gram spray bottle., red insulating varnish-class f epoxy insulation & protection coating., becktol gray varnish in 1 ltr tin dr.back make, thinier 221, 901 easyclean (nf) 500 ml. spray can - on line electrical contact cleaner., puff seal have polyurethene based foam sealing compound, silica gel blue 4 to 6 mm, heat shrinkable sleeve,size:45mm/18 mm( for 240/300 sq.mm )for 11 kv, mcb 4 pole, 32 amp, 440 volts, breaking capacity 10 ka, mcbs(3 pole+nutral) miniature circuit breker current rating 63amp., mcb 1 pole 25 amp,l 43125 ro, plug socket 6 amp 230v,5 hole, 3 pin plug top 6amp. 4657, single way switch 230 v, 6 amp. confirming is 3854., pvc adhesive insulation tape roll, ceiling fan capacitor, change over switch 63a x 415v x 4 pole, ictp switch 415 volts,100 amp. t.p. heavy duty., lighting panel with 18 outgoing c.k.t., supplied with double door,insulated busbar,insulated neutral bars,earth bar,cable ties,circuit identification lables, industrial padestal fan, wall mounting fan smart looks flexible tilting neck with toggle switch for oscillation control metal blades 230v 50hz. power saver., 4 pole, 100 amp, 415 volt, ac 23 a, 4p l&t make manual changeover switch ,disconnector, size fr1, catalogue no : co11000oooo, (conforms to iec 60947-3, is/iec 60947-3 ),type : open execution, push button station surface mounting type 3sb08 02-8ac, start-stop positions, siemens make, start push button green make:esbee ,230v,6a with n0 contact element, stop push button red make:esbee ,230v,6a with nc contact element, led type indication lamp, 22.5 dia, 240 v ac, red colour with lvgp, led indication lamp 22.5mm dia colour:-red voltage:-110vac make:-l&t cat no.:-eplr110a, 4 switch and 1 socket pvc switch board, 4 switch and 4 socket pvc switch board, ht pvc insulation tape size 0.18 mm x25 mm x 65 mtr length, 2 switch pvc switch board, 3 core , 6 mm sq. flexible pvc insulated copper cable, flexible unsheathed pvc insulated copper cable of size 4 corex6 sqmm, 1.1 kv busbar /cable couductor protection heat shrinkable sleeve dia .before shrink: 50 mm dia. after shrink : 16 mm for 1.1 kv lt cable, pvc flat copper cable 3 corex35 sqmm for submercible pump, 1100 v grade, multi-stranded, unarmored flat copper cable, pvc insulated, for submersible pump, as per is 694, 1990 size :3 c x 70 mm2
Tender For bid to ras supply of demand of maint stores d d-- led batten (q2) , self ballasted led lamps for general lighting services (v2) conforming to is 16102 (q2) , led luminaire for road and street lights (v2) conforming to is 10322 (part 5 / section 3) (q3) , led luminaire for floodlight (v2) conforming to is 10322 (part 5/section 5) (q3) , molded case circuit breakers (mccb) as per is / iec 60947 (q3) , xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1) (q2) , pvc copper cable single core and multi core circular sheathed cord with flexible conductor (v2) as per is 694 (q2) , piano type modular domestic fan regulator as per is 11037 (q3) , piano type non modular domestic fan regulator as per is 11037 (q3) , modular piano type domestic electrical switches as per is 3854 (q3) , piano type non modular electrical switch socket combination as per is 3854 and is 1293 (q3) , 10 sqmm 2 core pvc service cable , 4 sqmm 2 core pvc service cable , 6 sqmm 2 core pvc service cable , 2.5 mfd capacitor , 18w led panel light , 16amp 3 pin plug top , 6amp 3 pin plug top , 16amp 1 way piano type switch , 6amp 1 way piano type switch , 6amp 2 way piano type switch , 15amp socket , 5amp 5pin switch socket combination , 60w led batten , led thread type 9 or 12w , 16amp 4 pole power contractor
Tender For corrigendum : enquiry for rate contract for supply of maintenance items - various tripping coil, various closing coil, expulsion fuse 20 a. for capacitor bank ( for 100 kvar unit ), expulsion fuse 40a for capacitor bank ( for 200 kvar unit ), silica gel, breather for ptr (capacity- 3 kg.), c&r panel indicators, selector switch, tnc switch, mfm, bucholz relay, mog, 33 kv stud 20 mm suitable for ptr, 11 kv stud 20 mm suitable for ptr, 33 kv bushing for ptr suitable for 20 mm stud, 11 kv bushing for ptr for 20 mm stud, smart clamp/bimetallic clamp for ptr bushing stud size 20 mm, gi nut bolts assorted size, rubberized cork seat 4 mm (2 x 3 ft.), rubberized cork seat 10 mm (2 x 3 ft.), oil temperature indicator (oti), dial 150mm , with capillary, mercury switch type, winding temperature indicator (wti), dial 150mm , with capillary, mercury switch type, smart t clamp of all sizes, smart pg clamp of all sizes, isolator pad clamp for raccoon & dog conductor, silica gel, robust fuse unit, (i) rubber conical washer suitable for 12 mm stud(hv side), (ii) rubber conical washer suitable for 12 mm stud (lv side), gi nut bolt & washers assorted size, bamboo ladder, (i) do fuse element for dtrs 25 kva -- 1.3 amp, (ii) do fuse element for dtrs 63 kva -- 3.3 amp., (iii) do fuse element for dtrs 100 kva -- 5 amp., (iv) do fuse element for dtrs 200 kva -- 10 amp, (v) do fuse element for dtrs 315 kva -- 15 amp, (i) hrc fuse 125 amp, (ii) hrc fuse 250 amp, (iii) hrc fuse 400 amp, (i) hrc fuse base dtr 100 kva, (ii) hrc fuse base dtr 200 kva, (iii) hrc fuse base dtr 315 kva, (i) tc fuse wire 25 kva -- 36 amp - 21 swg, (ii) tc fuse wire 63 kva -- 89 amp. - 18swg, (iii) tc fuse wire 100 kva -- 131 amp. - 2*16 swg, (iv) tc fuse wire 200 kva -- 262 amp - 2*15 swg, (v) tc fuse wire 315 kva -- 454 amp - 2*15*2 swg
Tender For rca for procurement of local purchase materials required for operations and maintenance of equipmets of 33/11 kv s/ under city cirle bhopal. - computer items :, various tripping coiltripping coils 30v for stelmec, 11 ky vcb with assembly specification:operating voltage: 30v dccoil resistance: 3.2 0.1ohmmake: sunkid/rabco/ssrcomplete metal enclosure, various tripping coiltripping coils schneider/areva only coilspecification:operating voltage: 30v dccoil resistance: 8.7 0.1ohmbobbin-outer diameter: 46mminner diameter: 16mmheight: 40mmcopper woundwith 0.5 meters insulated pvc 1.5 sqmm wireoverall min weight of coil: 225gms, various tripping coiltripping coils crompton with assymblyspecification:operating voltage: 30v dccoil resistance: 2.4ohm20.1ohmbobbin outer diameter: 51mminner diameter: 20mmheight: 48mmcopper wound with 0.5 meters insulated pvc 1.5 sqmm wireoverall weight of coil: 300gms, various tripping coil tripping coils 30v for megawin, with assemblyspecification:operating voltage: 30v dccoil resistance: 4.8:0.1 ohmsbobbin outer diameter: 42mminner diameter: 16mm (with brass tube)length: 93mmbrass tube length: 98mmplunger length: 140mmcopper wound and varnishedwith 0.25 meters insulated pvc 1.0 sqmm wireweight1) coil: 505gms2) plunger: 126gms3) minimum overall weight of coil: 960gms, various tripping coil tripping coils abbspecificationcomplete, model: ivc102950a01a, 24v, various tripping coiltripping coils bhel specification:bobbin outer diameter: 42mminner diameter: 16mm (with brass tube)length: 93mmbrass tube length: 98mmplunger length: 140mmcopper wound and varnishedwith 0.5 meters insulated pvc 1.0 sqmm wireweight:1) coil: 505gms2) plunger: 126gms3) minimum overall weight of coil: 965gms,, various tripping coil tripping coils shreem only specification:operating voltage: 30v dccoil resistance: 3.9.ohmsbobbin outer diameter: 51mminner diameter: 26mmheight: 51mmcopper wound with 0.5 meters insulated pvc 1.5 sqmm wirea-1nominimum overall weight of coil: 395gm, various closing coil 30 volt closing coil with assembly suitable for 11 kv stelmec make-vcb length of coil 37 mm, i.d. 14 mm., o.d. 31 mm., resistance 3.3 ohm tolarance 0.1 ohm.. weight coil 120 gram, total weight with assembly 265 gram overall length 88 mm, various closing coil 30 volt closing coil with assembly of 11 kv crompton make, various closing coil 30 volt closing coil with assembly of 11 kv bhel make, various closing coil 30 volt closing coil with assembly of 11 kv abb make, various closing coil 30 volt closing coil with assembly of 11 kv megawin make, various closing coil 30 volt closing coil with assembly of 11 kv schnieder/areva make, various closing coil 30 volt closing coil with assembly of 11 kv shreem make, expulsion fuse 20 a. for capacitor bank ( for 100 kvar unit, expulsion fuse 40a for capacitor bank ( for 200 kvar unit ), breather for ptr (capacity- 3 kg.), robust high ampacity smart connector for ct/pt/me, m-16, robust high ampacity smart connector for ct/pt/me, m-20, c&r panel indicators, tnc switch, mfm, buchholz relay, mog, 11 kv vacuum interrupter make- cg (suitable for cg/megawin/bhel), 11 kv vacuum interrupter make- stelmec (suitable for stelmec), robust high ampacity smart connector for ptr of size m-20 for raccoon connec, robust high ampacity smart connector for ptr of size m-20 for panther, gi nut bolts assorted size, rubber cork seat 4 mm , rubber cork seat 10 mm , oil temperature indicator (oti) , winding temperature indicator (wti) , smart t clamp of all sizes racoon conductor, smart t clamp of all sizes dog conductor, smart t clamp of all sizes panther conductor, smart pg clamp of all sizes panther conductor, smart pg clamp of all sizes racoon conductor, smart pg clamp of all sizes dog conductor, isolator pad clamp, 30 volt dc bell, ampere meter selector switch, voltmeter selector switch, dc mcb 16 amp, ac mcb 16 amp, mft (multi-functional transducer), cmr ( contact multiplying relay), auxiliary switch-8 no+8 nc ( suitable f
Tender For shifting of electrical equipment with associated material from rsu nangal raya to t.e. bldg. janak puri, delhi - dismantling of 2 nos. dg set 75 kva complete with batteries, exhaust pipes, cables, panel(inside canopy) from rsu nangal i/c dismantling of all cable, earthing & exhaust pipe connection etc. complete as reqd., dismantling of 3x8.75 tr ductable ac units from rsu nangal i/c dismantling of indoor & outdoor units, piping, cable tray, drain pipe and cable, connection etc. complete as reqd., dismantling of one 3x31.5 kva avr from rsu nangal i/c dismantling of all type cables, earthing connection etc. complete as reqd., dismantling of the following material from rsu nangal i/c dismantling of all types of cables/conduits, earthing connection etc. complete as reqd.: capacitorpanel, avr by pass panel, l t panel, ac panel, fire panel, wall fans, fittings, phase reversal, change over switches, distribution boards, cable trays, cables, celing/wall fans, exhaust fans, and fire detectors etc complete as required., loading & unloading of dg sets with associate material i/c transportation from rsu nangal to t.e. bldg. janak puri by heavy labour, chain pulley/hydra etc as reqd., loading & unloading of 3x8.75 tr ductable ac units i/c indoor units & outdoor units, piping, cable tray and cable, etc. i/c transportation from rsu nangal to t.e. bldg. janak puri, by heavy labour,,chain pulley/hydra etc as reqd., loading & unloading of 3x31.5 kva avr with associated material etc.complete as reqd. i/c transportation from rsu nangal to t.e. bldg. janak puri, by heavy labour, chain pulley/hydra etc as reqd., shifting of the following material from rsu nangal i/c loading of all types of cables/conduits, earthing connections, capacitorpanel, avr by pass panel, l t panel, ac panel, fire panel, wall fans, fittings, phase reversal, change over switches, distribution boards, cable trays, cables, celing/wall fans, exhaust fans, and fire detectors etc. unloading at janak puri bldg., and location as per the directions of engineer-in-charge. note: 1) the agency has to prepare a detailed inventory of all items to be dismantled i/c quantity before dismantling and shifting to other site and submit it to the engineer-in-charge for taking gate pass. 2) the agency is fully responsible for any misplaced/short material receipt from rsu site and suitable recovery will be made for any such item. 3) the cables will be rolled into loops and approximate length should be mentioned in inventory. 4) the dismantled items alongwith inventory will be handed over to engineer-in-charge, after shifting the material at site.
Tender For repair/ replacement and maintenance of lt switch gear, panel, apfc panel, capacitor bank and connected item at certain location of training bn of 1 eme centre, hq tasa under age em i of ge(u) secunderabad
Tender For repairs/ replacement and maintenance of lt switch gear, panel, apfc panel, capacitor bank and connected item at certain location of or md/ jco md accn of trishul line area, sanjay line area, lake line area and certain area under age em i of ge(u) sec
Tender For replacement of existing main essential panel, pump panel, capacitor bank panels in the existing substation installed at cdsco campus, sanathnagar, hyderabad.