Web Analytics Made Easy - StatCounter

Carbon Analyzer Tenders

Get complete information related to latest Carbon Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Carbon Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Carbon Analyzer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :43289644 Due date: 20 Jan, 202620 Jan, 2026 NA
Tender For providing of testing service for on-board /commissioned equipment/ instrument related to plant - electrical, chemical; insulation resistance, residual life analysis (rla) study of transformers a ) cap. & tan delta (b) sfra (c) turn's ratio (d) mag. current (e) ma..

CTN :42096624 Due date: 24 Dec, 202524 Dec, 2025 NA
Location: Goa - Goa Goa - Goa
Tender For bid to ras corrigendum : custom bid for services - repair of mps 12 unit part no mkld 466229 050 tu sl no 050100745; details of items. (a) description (b) part no mps-12 unit mkld.466229.050 tu (c) make russia (d) si no. 050100745 (e) year of purchase 2016. 2. purpose. the mps-12 unit, pt. no. mkld.466229.050 tu is microcomputer based equipment designed to display aircraft radar data and status of radar equipments on the screen. 3. defects. mps-12 unit, pt. no. mkld.466229.050 tu, si no. 050100745 has been loaded on repair order vide repair order k/ro/k31/2024/2148 dated 06 apr 24 by mo (goa). during function checks of the unit found display becomes white after 5 minutes of operation. further unit confirmed defective during workshop test. 4. repair. (a) identifying the defect utilising the standard electrical and electronic tests/ fault analysis techniques available in the industry. the work is required to be undertaken by qualified technicians. support document for qualified technicians be submitted by the firm. the repair methodology/ repair process undertaken to identify defective component be submitted. (b) replacement of defective bds by utilising mil standard serviceable spares supplied by oem/ oem authorised vendors. suitable certificate of conformity from firm be submitted. further, colour photographs/ video recordings of components replaced during the repairs be submitted with old items replaced. (c) submission of report regarding details of testing, if any, carried out for mps-12 unit in the firm premises. in case such test has been undertaken at firm nromioca thon details of the equipment utilised for testing and qa clearance/ ca applicable) of the test set be submitted. (d) association of firm's engineers for functional, integration anu user acceptance trials at nay (goa). (e) certificate of origin from firm be provided (if imported spares are used). (f) warranty certificates from firm be provided (as applicable). (g) inspection by the yard qa would be undertaken post completion of repairs during user acceptance trials which includes functional checks on aircraft, inspection for transit damage/ visual checks for abnormalities, correctness and completeness of item along with valid documents as per repair order. (h) the item will be tested on sk-801 radar test bench at workshop. if the item fails during testing, the firm agrees to undertake repairs of the item on foc basis irrespective of time elapsed since supply of item to indian navy..

CTN :43185676 Due date: 05 Jan, 202605 Jan, 2026 NA
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer- the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks.warranty must be one year., electronic balance- the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. warranty must be one year., vaccum pump - the pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted withvacuum and filter cartridge., hot air oven- the inner chamber should be made of stainlesssteel and the outer chamber should be m.s powdercoated. the maximum capacity of the oven shouldbe 100 ml or more. the operational temperatureshould be between ambient to 250oc or more witha temperature accuracy of 1o c. pid based digitaltemperature control., double distillation unit- the unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil bath- the oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240oc (0.1oc increment) with a temperature stability of 1oc, water bath- the water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars., ph/ condutivity meter - operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range shouldbe in between 0.00 to 29.99 s/cm, uv cabinet- operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometer- application: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca 2+ :0-99.9 ppmli 2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required

Central Government/Public Sector

CTN :42775293 Due date: 27 Dec, 202527 Dec, 2025 NA
Tender For corrigendum : supply of eye tracker with data analysis software : :--eye tracker with data analysis software with 01 year warranty , 02nd year warranty cost of equipment , 3rd year warranty cost of equipment , 04th year warranty cost of equipmen , 05th year warranty cost of equipment , desktop computer

CTN :43188410 Due date: 30 Dec, 202530 Dec, 2025 18.14 Lacs
Tender For supply of electrical engineering department laboratory equipment c c -single phase transformers , three phase transformer trainer , 3 point starter for 5 hp dc motor, 230 v dc, 20a , dc shunt motor coupled with three phase alternator with control panel , synchronizing panel for dc shunt motor coupled with three phase alternator , b-h curve kit. , dc power supply 5 a 220v , three phase smart energy meter trainer , non contact type tachometer , transient analysis of rlc, rc and rl circuit trainer , single and three phase resistive load bank , dc power supply 0 to 10 a , bldc motor , single phase induction motor trainer , three section radial feeder protection single phase setup , scott connection trainer , machine winding trainer

Central Government/Public Sector

CTN :43055491 Due date: 26 Dec, 202526 Dec, 2025 NA
Tender For corrigendum : procurement of dental items, lab consumables and medical equipment for onward supplies to foreign country - list of products, gumtone gel (charac) 50 gm, desensitizing paste (thermoseal) 100 gm, metohex-plus gel (chlorhexidine gluconate 0.25% + metronidazole 10 mg, zinc oxide powder 110g- packet, zinc phosphate cement powder - 30g, plastic filling instruments pfi, spoon excavators, condensers (cylindrical), ball burnishers, k-files 21mm, 10, 15, 20, 25, 30, 35, 40 (mani india), h-files 21mm, 10, 15, 20, 25, 30, 35, 40 (mani india), barbed broaches 15, 20, 25, (mani, india ), rotary files, protaper gold files, 0.6% (21mm only), dentsply sirona gold, 10-21mm, s1, purple, rotary files, protaper gold files, 0.6% (21mm only), dentsply sirona gold, 15-21mm, s2, white, rotary files, protaper gold files, 0.6% (21mm only), dentsply sirona gold, 20-21mm, f1, yellow, rotary files, protaper gold files, 0.6% (21mm only), dentsply sirona gold, 25-21mm, f2, red, carbide burs (ss white)- straight, carbide burs (ss white)- round, micromotor lab burs- acrylic burs, green stone burs, metal burs (pear/cylindrical shape), disposable plastic mouth mirrors and probe sets, triamcinolone acetate cream, disposable suction tips, chlorhexidine gluconate 0.2% medicated mouthwash 0.2%w/v 150ml bottle, disposable 3 way syringe tips, sterile cotton balls, sterile cotton pellets, sterile plastic sleeves, sterilization pouch rolls color changing, hard surface disinfectant spray (ddca- dimethyl ammonium chloride purestat, spi), glass inomor cement type-1 luting - gc fuji only, glass inomor cement type-2 - restorative - gc fuji only, glass inomor cement type-9 - high strength restorative posterior - gc fuji only, sdf (silver diamine fluoride) - 38% saforide, fa gamin, zinc oxide powder (15g) & eugenol liquid (10ml) - prime dental, temporary filling material (reinforced znoe) - cavit, calcium hydroxide base (hard setting)- dycal, calcium hydroxide + iodoform paste- metapex, root canal sealer - ah 26 sealer, gutta percha (0.6%) - 15 (s2 white), gutta percha (0.6%)- 20 (f1 yellow), gutta percha (0.6%)- 25 (f2 red), self cure acrylic (pink & white) - powder (for denture repair), self cure acrylic (pink & white) - liquid (for denture repair), ornidazole oral gel (ornigreat - mankind), wire cutters ss, artery forceps straight, wire holder, tissue forceps small, metal suction tips small, metal suction tips large, endomotor - cordless with/without apex locator (marathon/woodpecker/morita), micromotor unit external (marathon), micromotor handpiece straight (marathon/ems/supreme), micromotor handpiece contra-angle (marathon/ems/supreme), airotor cartridges super torque for nsk handpiece (push-button model), heat seal machine, black cap vacutainer (with sodium citrate) for esr estimation, borosilicate transparent test tube for lab, size: 12mmx75mm legth, edta vacutainers purple cap, edta vacutainers pink cap, fluoride vacutainers grey cap, glass slides with label ( 75mm x 25 mm) pack of 72 slide, glucostrips acucheck active, hbsag card (rapid test) 25 test, hcv card (rapid test) piece, hydrogen peroxide 6% solution, pregnancy test kit (hcg), sodium hypochlorite liquid, tongue depressor wodden (sterile), trop-t card test, lancets, urine analysis test strips 10 parameters, sob kit (fluorescence immunoassay device designed to determine the concentration of ck-mb, myoglobin, troponin), cover slips small size, arm sling pouchwith shouder pad and elbow support, universal size(right- 50, left-50), crepe bandage 6 (15cm), 4-6 meter/roll, elastic crape bandage adhesive for ortho use (6 inches and 4 inches), crepe bandage 4 "(10cm), 4-6 meter/roll, knee cap (m), knee cap (l), knee cap (xl), lumbo sacral support belt (universal size 70-112 cms), rib belt for ortho use, universal size, dynaplast(elastic crape bandage) adhesive for ortho use, dvt compression stockings for ortho use(m), dvt compression stockings for ortho use(l), synthetic splint for ortho use(

Central Government/Public Sector

CTN :43171387 Due date: 03 Jan, 202603 Jan, 2026 NA
Tender For providing of testing service for on-board /commissioned equipment/ instrument related to plant - total price including all applicable taxes and duties for biennial rate contract for vibration monitoring and analysis of rotary equipment for finding root cause of t..

Central Government And Public Sector

CTN :43211595 Due date: 09 Jan, 202609 Jan, 2026 NA
Tender For supply, installation and commissioning of one set of equipment/system for measurement/determination of stress free temperature of lwr/cwr for indian railways and executing the work of measurement/determination of stress free temperature of lwr/cwr and further analysis for taking maintenance decisions for a period of one year which will cover all seasons of the year or 500 kms whichever is more.

Central Government / Public Sector

CTN :42452833 Due date: 30 Dec, 202530 Dec, 2025 NA
Tender For corrigendum : supply of procurement of automated spectrum management system solution : : - design, development, deployment of technical analysis module, customization of the software, uat and security audit , design, development and deployment of integration with saral sanchar or any other portal of dot , design, development and deployment of integration with monitoring equipment , training-1 , training-2 , miscellaneous

CTN :42901834 Due date: 24 Dec, 202524 Dec, 2025 NA
Tender For corrigendum : purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp freque
 Loading, Please wait...

Connect us via What's Up