Tender For diagnostic and therapeutic items for cardiac cath lab (group b) - ecgelectrodesofhighqualitymaterialtominimize interference and signal distortion during prolonged cardiology procedurest (fda/ce approved), manifoldwithtwosideportsforptca(fda/ce approved), manifoldwiththreesideportsforptca(fda/ce approved), tefloncoatedguidewires(j-tip&straight-tip)standard length-145 or 150cm (fda/ce approved), tefloncoatedguidewires(j-tips&straight-tip)exchange length-260 or 300cm (fda/ce approved), femoral introducer sheath with puncture needle for adults (sizes 5 - 11 fr.) standard length; 10-16-25 cm long; 0.021 or 0.025-inch guide wire compatible. material of sheath tubing should be made of etfe, cross cut valve should be made up of silicon rubber & should have silicone coating. dilator tube should be made up of polypropylene and should have silicon coating. must have with haemostatic crosscut valve; with integrated side arm with attached 3-way stopcock; with suture eye for securing sheath and click sound; kink resistant. must have with dilator-hub lock mechanism to prevent its back-out during insertion; pack must include with or without metallic needle usfda approved, longintroducersheath(20-50cmlong)(fda/ce approved), extra-longintroducersheath(>50cm)(fda/ceapproved), radial introducer kit with puncture needle for adults (sizes 5 - 7 fr.) standard length 7 cm long; 0.035 or 0.038-inch guide wire compatible, include surflash 20g*2 entry needle (plastic iv catheter) and 0.025 mini plastic guidewire must have etfe sheath tubing, dilator tube should be made up of polypropylene and should have silicon coating.should contain a haemostatic crosscut valve to prevent back leak of blood and aspiration of air; with integrated side arm with attached 3-way stopcock, transradialcoronarydiagnosticcatheter (us fda approved) of various lengths, syringeforpressureinjector-150mlwithpressuretubing compatiblewiththeavailablesysteminthecathlab(medred-mark-7)arterion, highpressureconnectingtubingupto50cmslong for pressuresyringe, a). coronarydiagnosticangiographycatheter(judkinstype- leftandright)(us fda, b). coronary diagnostic angiography catheters ( judkins type) europeanceapproved), a). diagnosticcoronaryangiographycatheter(amplatztype- leftandright)(us fda), b). diagnostic coronary angiographic catheter ( amplaz type left &righceapproved), pigtailcatheters(fda/ceapproved), shortpigtailforpericardiocentesis, diagnosticmultipurposecatheters(fda/ceapproved), nihcatheter(fda/ceapproved), imacatheter(fda/ceapproved), ptcainflationdevice-analogdisplay(ballooninflation, deviceanalogdisplay,30atmpressurewithtubingand3, waystopcock)(fda/ceapproved), y-connectorsetwithextensiontubingtuohyburst,pci, needleand3-way, specialy-connectorsetwithbothfixedandhaemostatic, valvewithupto10frinnerdiameter, pcineedlewith/withouttorquerdevice, disposableplasticsterileluerlocksyringerfor angiographyandptca(leurlock), largelumenptcaguidingcathetersof5to8fr sizes-fda approved, largelumenptcaguidingcathetersof5to8fr sizes-ce approved, brkneedle(fda/ceapproved)for paediatrics/adults, embolicprotection(distalprotection)device(epd)for ptca (fda approved), embolicprotection(distalprotection)device(epd)for ptca (ce approved), manualthrombosuctioncatheterforptca(fda approved), manualthrombosuctioncatheterforptca(ceapproved), radialarterycompressiondevice, crossoverarterialsheaths(fdaapproved), snareloop(fdaapproved), snareloop(ce approved), micrograbber(fda approved), micrograbber(ceapproved), intravascularretrieversnareofvarioussizeswithsingle foldable loop, intravascularretrieversnare-twoloops(gooseneck type), intravascularretrieversnare-threeormoreloops (gooseneck type), pericardiocentesiskit(fda/ceapproved), pigtailcatheterwithmultiplemarkers(fdaapproved), rotalinkplussystem, rotalinkprosystem, rotalinkguidewire, intracoronarypressurewire(ffr)forptca-compatible with abbott vascular, ivuscatheterforcoronaryinterventionscompatiblewith boston scientific vascular, ivushdco
Tender For supply of cardiac surgery consumables - chest binder , coach 2 2500 ml one way valve spirometer , pressure monitoring kit with dual transducer , introducer sheath for pa catheter size 8.5 fr , maltodextrin and stevia leaves based pre surgery carbohydrate drink 355 ml
Tender For corrigendum : e-bid for the finalization of rate contract for the procurement of diagnostic & therapeutic items for cardiac cath lab for the year 2025-27 group -b - ecg electrodes of high quality material to minimize interference and signal distortion during prolonged cardiology procedurest (fda/ce approved), manifold with two side ports for ptca (fda/ce approved), manifold with three side ports for ptca (fda/ce approved), teflon coated guide wires (j-tip & straight-tip) standard length-145 or 150cm (fda/ce approved), teflon coated guidewires(j-tips & straight-tip) exchange length-260 or 300cm (fda/ce approved), trans femoral introducer sheath with mini guide wire and puncture needle (fda/ce approved), long introducer sheath (20-50cm long) (fda/ce approved), extra-long introducer sheath (>50 cm) (fda/ce approved), trans radial introducer kit with mini guide wire and puncture needle (fda/ce approved), trans radial coronary diagnostic catheter (fda/ce approved), syringe for pressure injector-150ml with pressure tubing compatible with the available system in the cath lab (medred-mark-7) arterion, high pressure connecting tubing up to 50 cms long for pressure syringe, act cartridges compatible with the available machine in the cath lab (sonoclot-sienco-inc. & medtronic), diagnostic coronary angiography catheter(judkins type-left and right) (fda/ce approved) all sizes, diagnostic coronary angiography catheter(amplatz type-left and right) (fda/ce approved) all sizes, pigtail catheters (fda/ce approved), short pigtail for pericardiocentesis, diagnostic multipurpose catheters (fda/ce approved), nih catheter (fda/ce approved), ima catheter (fda/ce approved), ptca inflation device-analog display (balloon inflation device analog display, 30 atm pressure with tubing and 3 way stopcock) (fda/ce approved), y-connector set with extension tubing tuohy burst, pci needle and 3-way, special y-connector set with both fixed and haemostatic valve with upto 10 fr inner diameter, pci needle with/without torquer device, disposable plastic sterile luer lock syringer for angiography and ptca (leur lock), large lumen ptca guiding catheters of 5 to 8 fr sizes-fda approved, large lumen ptca guiding catheters of 5 to 8 fr sizes-ce approved, brk needle (fda/ce approved) for paediatrics/adults, patch electrodes for defibrillation compatible with the available machines in the cath lab(nihon-cohden & lifepack-20, iabp balloon catheter (fda/ce approved) compatible with the available machine (maquet) in cathlab, embolic protection (distal protection) device (epd) for ptca (fda approved), embolic protection (distal protection) device (epd) for ptca (ce approved), manual thrombosuction catheter for ptca (fda approved), manual thrombosuction catheter for ptca (ce approved), radial artery compression device, cross over arterial sheaths(fda approved), snare loop (fda approved), snare loop (ce approved), micro grabber (fda approved), micro grabber(ce approved), intra vascular retriever snare of various sizes with single foldable loop, intra vascular retriever snare-two loops (gooseneck type), intra vascular retriever snare-three or more loops (gooseneck type), pericardiocentesis kit (fda/ce approved), pigtail catheter with multiple markers (fda approved), rotalink plus system, rotalink pro system, rotalink guidewire, intracoronary pressure wire (ffr) for ptca-compatible with abbott vascular, ivus catheter for coronary interventions compatible with abbott vascular, ivus hd compatible catheter for coronary interventions, pharmacological hemostasis topical dry pad/bandage based mechanism, micropuncture needle with stainless steel guidewire for adults, paediatric & neonatal use, micropuncture needle with hydrophilic guidewire for adults, paediatric & neonatal vascular access, introducer sheath for use in neonates, mullins sheath with side arm (4-14 fr), percutaneous transluminal valvuloplasty balloon (compatible with 5 fr-7 fr, 0.018-0.035 inch