Web Analytics Made Easy - StatCounter

Carrying Case Tenders

Get complete information related to latest Carrying Case Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Carrying Case Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Carrying Case Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41044984 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For supply of hell fire payload dropping f p v drone features payload 500 grams payload m m h g endurance upto 20 min mode piloted and auto application payload dropping , controller with screen , charger , batteries , carrying case

CTN :41044985 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For supply of hell fire kamikaze dropping f p v drone features payload 500 grams payload m m h g endurance upto 20 min mode piloted and auto application payload dropping , controller with screen , charger , batteries , carrying case

CTN :41002883 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For corrigendum : supply of charger e e - traning model for tech traning of tps in drone warfare , traning quad copter for traning of tps on drone technology , mini quad copter for traning of observation parties on drone warfare , carrying case , charger

CTN :41011030 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For supply of 32 channel data acquisition system ssd , 4 channel voltage module , 2 channel voltage module , 2 channel high speed voltage module , input cable 2m with insulated bnc cable alligator clip , hard carrying case with castor wheels , thermal paper rolls

CTN :40978215 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For supply of ftth splicer for enhancement of regtl comn , plastic mouled dedicated carrying case for splicer for enhancement of regtl comn , high precision cutting knige , miller forceps for enhancement of regtl comn , cord stipper for enhancement of regtl comn , cat 6 cable for enhancement of regtl comn , cooling tray for enhancement of regtl comn

corporations/Associations/Others

CTN :40991461 Due date: 25 Jul, 202525 Jul, 2025 NA
Tender For auction sale of bty o/s,wheel disc o/s,radiator o/s,gen set 5.6kva trolley mtd,gen set 30kva trolley mtd,gen set 5.5kva trolley mtd,gen set 11.2kva trolley mtd,gen set 11kva trolley mtd,steel scrap (track link),steel scrap (track link assy),mt scrap,steel scrap (rod spring),bty scrap,tarpauline o/s,helmet o/s,bicycle os,steel scrap,steel scrap (water tank),tarpauline old,textile old,net mosquito,tentage old,computer o/s,engine o/s,case & cradle os,eng assy tatra,steel scrap (hard metal loader ramp),plastic scrap (ice box)

State Government

CTN :40985783 Due date: 28 Jul, 202528 Jul, 2025 1.50 Crore
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a

State Government

CTN :40985789 Due date: 28 Jul, 202528 Jul, 2025 3.50 Crore
Tender For purchase of biomechanical lab - force platedimensions (w x d x h) in mm : 600 x 400 x up to 50 number of axes for force measurement: all 3 axes. x,y,z plate should be portable in naturesensor type: piezoelectricsampling frequency-(hz) =1000 hz or more force measured on each axis-fx,fy: 2,000 newton or more, fz: 10,000 newton or more hysteresis- (%fso): 0.5 linearity (%fso) 0.5 crosstalk (%) : 2water resistance rating: ip 50 or better.should be inclusive of installation.should be supplied with carrying case for 2 plates and noise free ups for on-ground assessment. the carrying case should be strong and sturdy.should be able to accommodate portable force plate 9286 ba, daq box 5695 and connecting cablesshould be able to protect the equipment from rain, impact and dust, should have rollers to move easilyshould be able to accommodate an ups also., isokinetic dynamometershould be able to access/test various joints in isolation should be able to meet requirements to test sports personsshould be able to test in different resistance modes such as isokinetic (concentric-concentric, concentric-eccentric ,eccentric, concentric ,and eccentric-eccentric), isotonic, isometric, and passive protocols should include options for angles, hold-times, rest period, repetitions, and sets. the system should be able to test all the major body segments and joints such as shoulder, forearm, elbow, wrist, hip, knee, and ankle.should have adjustable range of motion stops in full 360 degrees.should have 360-degree rotation for the force arm (connecting dynamometer to the pedal) to have wide range of motionshould be able to accommodate different athletes with varying height and weight with provision for seatbelt harness for better stabilitythe dynamometer or chair should be movable to accommodate different athletes for quick set-up and better usability with locking clamps for securing the system in place for testingshould be able to do gravity correction when the limbs are positioned with the lever arm on the dynamometerthe software should be provided to analyze the raw data and export the raw and processed data in different file formats such as excel, text, etc. the software should provide detailed report for various testing protocols such as individual test for joints, data/graph overlay for comparing pre and post testing, repeatability, progress, multi-session.should be provided with latest compatible workstation/laptop of reputed brand like hp, dell (latest generation) processor, minimum16gb ram, windows os 11, and laser printerconcentric speed: 500 deg/sec or more eccentric speed: 500 deg/sec or more concentric torque: 500 ft-lb (678nm) or more eccentric torque: 500 ft-lb (678 nm) or more isometric torque: 500 ft-lb (678 nm) or more isotonic torque: 500 ft-lb (678 nm) or more isotonic torque as low as .5 ft-lbfeedback formats: roadway, interactive line, interactive path, reaction training, proprioception training, breakout, and pong.torques. time, torques. angle, torque bars, work bars, power bars. it should be possible to use mechanical stops even with custom patterns (important for safety in research)the same attachment should be usable for left and right side of subject for consistencies in data.should be certified and approved by ce/eu medical devices directives or usfda, nord boardit should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless connectivity connec

Central Government/Public Sector

CTN :41001031 Due date: 17 Jul, 202517 Jul, 2025 NA
Tender For wheel diameter gauge model wd-2 (e) with digital display for measurement of wheel diameter in both mounted (in situ) and unmounted wheels of track machines. specifi cation: - (1) measuring range: - 650 to 1250 mm (2) accuracy: +/- 0.2 mm (3) applicability: - b g wheels (4) resolutions: - 0.1 mm/0.01 mm /0.001 mm (selectable) (5) measurement at distance of edge: - 63.5 mm (6) distance between axes of ball base: - 250+/-0.5 mm (7) display: - wireles s display on android 7 segment led/lcd (8) power supply: - inbuilt rechargeable battery (9) operating temperature: -10 degree celsius to 60 degree celsius (10) operating humidity: - 15 -85% (no condensation) (11) storage of data: - wireless data transmission with unlimited d ata storage (12) measurement scheme: - 3 point measurement of curve using linear encoder (13) carrying case: - padded ruggedized pvc carrying (14)case functionability: - measureme nt of wheel diameter is possible for loose wheel set as well as without dismantling wheel set. (15) recording of readings: - optional facility on android/device (16) data transfer: - t hrough wireless. part make: pie/ mitutoyo/ hy tech [ warranty period: 30 months after the date of d elivery ]

Central Government/Public Sector

CTN :40957844 Due date: 30 Jul, 202530 Jul, 2025 NA
Tender For digital electronic spirit level horizontal vial &vertical vial 800 millimeter, electronics measurement accuracy@ 0de g and 90deg (+/-)-0.1 degree, electronics measurement accuracy- 0.2 degree, laser working range-30 meter, led display, 9 v alk aline non rechargeable battery, stainless steel body with protective carrying case / bag. warranty period: 36 month(s) from the da te of supply. [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up