Web Analytics Made Easy - StatCounter

Catapult System Tenders

Get complete information related to latest Catapult System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Catapult System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Catapult System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :40494646 Due date: 16 Jun, 202516 Jun, 2025 NA
Tender For sensors and measurement lab equipment - purchase of sensors & measurements laboratory, voltage, current and power measurement in single phase ac circuit digital power monitor- 10 asingle phase variac 0-240 v, 5 arheostat as load -500 , 5 avoltmeter 0-300 vammeter 0- 5 awattmeter analog 0-3000 welectrical panel & wiring , measurement of current in 3 phase circuit using single ammeter ammeter selector switch 440 v, 6 a 3 loading 5 a 3 phase variac 5 acurrent transformer 3 nos.ammeter 0-10 aelectrical panel, wiring & switches, measurement of resistance using wheatstone bridge necessary connecters provided to connect four arms range of measurement: 5 - 100k accuracy (min to max.): +0.2tolerance: +5%one digital meter provided to indicate the balance conditionsbuilt-in power supplynecessary patch chordsdecade resistance box, measurement of earth resistance by earth tester suitable connectors for 4 main arms and 2 adjacent armspotentiometer to keep the bridge in balance condition.inbuilt 1 khz oscillatormeasuring range : 25mh - 500mhsensitivity : +2mhbulit in audio amplifier with speakerbuilt-in power supplynecessary patch chords decade inductance box, measurement of inductance using anderson bridge suitable connectors for 4 main arms and 2 adjacent armspotentiometer provided to keep the bridge in balance condition.inbuilt 1 khz oscillatormeasuring range : 25mh - 500mhsensitivity : +2mhbulit in audio amplifier with speakerbuilt-in power supplynecessary patch chords decade inductance box, measurement of capacitance using schering bridge suitable connectors with 4 arms providedprovision to connect the unknown capacitance at one armtwo potentiometers provided to keep the bridge balance condition.inbuilt 1 khz oscillator and audio amplifier with speakermeasuring range: 0.001uf - 2.0ufsensitivity: +0.1uftolerance : +5%decade capacitance box , temperature measurement thermocouple trainer kit sensor type: thermocouplerange: upto 99 degree centigradetemperature source: water bath ( 1 kw)bridge: full bridge configurationsignal conditioning output: (0-5) vdcdisplay: 31/2 digital led display & analog thermometeroperating voltage: +12 vdc. -12 vdc, + 5 vdc, - 5 vdctest points: 2 mm sockets, temperature measurement rtd trainer kit sensor type: rtd (pt100)range: up to 99 degree centigradetemperature source: water bath ( 1 kw)bridge: full bridge configurationsignal conditioning : (0-5) vdcdisplay: 31/2 digital led display & analog thermometeroperating voltage: +12 vdc. -12 vdc, + 5 vdc, - 5 vdctest points: 2 mm sockets , behavior of proximity sensors proximity sensor of inductive provided to detect the metallic object. capacitive sensor provided to detect both metal and non-metal object.switching circuits provided to actuate the buzzer and relay.inbuilt regulated power supply.housed in a powder coated cabinet, linear variable differential transformer measurement trainer type: inductiverange: (0-25) mmexcitation: 4 khz, 1 v pp sine wavecalibrated range: (0-20) mm or + 10 mm/-10 mmsignal conditioner output: 0-5 vdc or +5/-5 vdcdisplay: 31/2 display digit ledmicrometer range: (0-25) mmtest points: 2 mm sockets, performance of ultrasonic and moisture sensors arduino uno board ultrasonic sensor to measure the distance.moisture sensor to measure the humiditylcd displayselector switch for display of sensor output.regulated power supplymount in a closed cabinet

State Government

CTN :40071789 Due date: 02 Jun, 202502 Jun, 2025 NA
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above
 Loading, Please wait...

Connect us via What's Up