Get complete information related to latest Cc Pavement Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cc Pavement Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cc Pavement Tenders.
Tender For purchase of biomechanical lab - force platedimensions (w x d x h) in mm : 600 x 400 x up to 50 number of axes for force measurement: all 3 axes. x,y,z plate should be portable in naturesensor type: piezoelectricsampling frequency-(hz) =1000 hz or more force measured on each axis-fx,fy: 2,000 newton or more, fz: 10,000 newton or more hysteresis- (%fso): 0.5 linearity (%fso) 0.5 crosstalk (%) : 2water resistance rating: ip 50 or better.should be inclusive of installation.should be supplied with carrying case for 2 plates and noise free ups for on-ground assessment. the carrying case should be strong and sturdy.should be able to accommodate portable force plate 9286 ba, daq box 5695 and connecting cablesshould be able to protect the equipment from rain, impact and dust, should have rollers to move easilyshould be able to accommodate an ups also., isokinetic dynamometershould be able to access/test various joints in isolation should be able to meet requirements to test sports personsshould be able to test in different resistance modes such as isokinetic (concentric-concentric, concentric-eccentric ,eccentric, concentric ,and eccentric-eccentric), isotonic, isometric, and passive protocols should include options for angles, hold-times, rest period, repetitions, and sets. the system should be able to test all the major body segments and joints such as shoulder, forearm, elbow, wrist, hip, knee, and ankle.should have adjustable range of motion stops in full 360 degrees.should have 360-degree rotation for the force arm (connecting dynamometer to the pedal) to have wide range of motionshould be able to accommodate different athletes with varying height and weight with provision for seatbelt harness for better stabilitythe dynamometer or chair should be movable to accommodate different athletes for quick set-up and better usability with locking clamps for securing the system in place for testingshould be able to do gravity correction when the limbs are positioned with the lever arm on the dynamometerthe software should be provided to analyze the raw data and export the raw and processed data in different file formats such as excel, text, etc. the software should provide detailed report for various testing protocols such as individual test for joints, data/graph overlay for comparing pre and post testing, repeatability, progress, multi-session.should be provided with latest compatible workstation/laptop of reputed brand like hp, dell (latest generation) processor, minimum16gb ram, windows os 11, and laser printerconcentric speed: 500 deg/sec or more eccentric speed: 500 deg/sec or more concentric torque: 500 ft-lb (678nm) or more eccentric torque: 500 ft-lb (678 nm) or more isometric torque: 500 ft-lb (678 nm) or more isotonic torque: 500 ft-lb (678 nm) or more isotonic torque as low as .5 ft-lbfeedback formats: roadway, interactive line, interactive path, reaction training, proprioception training, breakout, and pong.torques. time, torques. angle, torque bars, work bars, power bars. it should be possible to use mechanical stops even with custom patterns (important for safety in research)the same attachment should be usable for left and right side of subject for consistencies in data.should be certified and approved by ce/eu medical devices directives or usfda, nord boardit should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless connectivity connec
Tender For repair and maintenance of infrastructure assets in r-iii division during 2025-26. sh- repair and maintenance of footpath and service lanes of shanti path road area under moti bagh r-iii
Tender For corrigendum : supply of chemicals, consumables and glasswares etc. required for smooth running of different laboratories under birbhum division, phe dte. - supply of chemicals & consumables etc. of different laboratories under birbhum division, phe dte, edta n/50 solution for total hardness analysis (500ml/pack)make : merck/fisher/sigma/finar, ammonia buffer solution for total hardness analysis (500 ml/pack) make : merck/fisher/sigma/finar, eriochrome black t indicator for total hardness analysis (25gm/pack) make: merck/fisher/sigma/finar, triethanolamine min 99.50% for total hardness analysis (500ml/pack) make : merck/fisher/sigma/finar, buffer ph 4.01@25 deg c calibration solution calibrated against nist traceable sbs (480ml pack) suitable for ino lab & ph510/700 ph meter.make : eutech/wtw/equiv, buffer ph 7.00@25 deg c calibration solution calibrated against nist traceable sbs (480ml pack).make : eutech/wtw/equiv, buffer ph 10.00@25 deg c calibration solution calibrated against nist traceable sbs (480ml pack).make : eutech/wtw/equiv, ph paper 2-10.5, reagent suitable for spectrophotometric analysis of iron in potable water, range 0.02-3.00 mg/l soluble iron (1000 tests/pack)make: merck/lovibond/palin/wtw, iron standard solution 1000 mg/l traceable to srm from nist traceable (125 ml/pack)make: inorg venture/reagecon/merck/sigma/equiv, reagent suitable for spectrophotometric analysis of manganese in potable water range : 0.1-10mg/l of manganese (250 tests/pack) make: merck/lovibond/palin/wtw, spectrophotometric reagent for fluoride analysis, range: 0.10-20.0 mg/l of f (250 tests/pack) make: merck/lovibond/palin/iv or equivalen, total ionic strength buffer solution-ill for fluoride estimation soln suitable for ionometric analysis of fluoride (475 ml/pack) thermo-orion/merck/carlo erba, fluoride standard solution traceable to srm from nist traceable (500 ml/pack) make: inorg vent/reagecon/merck/sigma/wtw, universal bridge electrolute electrode filling solution for fluoride ise, 5x50 ml, dpd tablet, chromogenic cotiform agar, for simulteneous determination & count of escherichia coli and total coliforms in water samples as per iso 9308-1:2014, 100 gm pack merck/himedia, consumables for bacteriological analysis by mf technique, membrane filter- cellulose nitrate, sterile- individually packed, white membrane, gridded, 47mm dia, 0.45 micron porosity, pack of 100 circles merck/himedia/axiva, consumables for bacteriological analysis by mf technique, radiation sterile plate 15x60 mm, 250 nos a pack., petridish autoclavable, borosilicate glass 60x15 mm, sterilising ether solvent (biosol) (450mi/pack), extran/labolene/finklin (5l/pack)make : merck/fisher/finar, aluminium foils 9mt -hindalco/equivalent, tissue paper, conductivity standard- 25 c, certified by iso 17025 accredited test method. nist traceable 1413us/cml at 25 c in 500 ml bottles, turbidity standard non ratio, 1000 ntu, certified by iso 17025 accredited test method. nist traceable, 500 ml, filter paper no: 542, 12.5 cm, whatman, iso propyl alcohol analytical quality, 500 ml, potassium iodide analytical quality, asay: min 99.8%, set of 200 gm, sodium thiosulfate pentahydrate, 500 gm, acetic acid glacial analytical grade, set of 1000 ml, starch soluble analytical quality, 500gm, edta disodium salt, analytical grade, 100 gm, sodium hydroxide analytical grade, 500 gm, manganese standard solution traceable to srm from nist traceable (125 ml.pack)make : inorg vent/reagecon/merck/sigma, water for chromatography, 1 lit pk, turbidity standard solution for tb 210ir, make: lovibond, formaldehyde 500 ml, borax, 500 gm, supply, delivery demonstration of residual chlorine kit complete with comparatorbox with continuous colour scale disc for residual chlorine & total chlorine analysis. range / gradation: 0/0.2/0.4/0.6/0.8/1.01.211.4/1.6/1.8/2.012.5/3.0/3.5/4.0, to be supplied with unbrakeable cells, frosted on two sides 13.5 mm path length, volume 10 ml, with lid, easily di
Tender For corrigendum : construction of atal path from newra road-gopasariya road to ladaniyo ki dhani via deramnagar adhuni dhani school km.0/0 to 2/500 (village newra road) package no -rj-21-ap-25-26-03