Web Analytics Made Easy - StatCounter

Cement Pole Repair Tenders

Get complete information related to latest Cement Pole Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cement Pole Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cement Pole Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41082917 Due date: 22 Jul, 202522 Jul, 2025 3.59 Crore
Tender For state scheme (nabard)/25-26/barsoi/01 - construction of hl rcc bridge from ganjan to vibhor hat road at ch.-1.720km, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. i) upto 3m depth, providing and constructing temporary island 8 m diameter for construction of pile foundation. assuming depth of water 4.0 m and height of island 4.5 m., dismantling of reinforced concrete pile head complete as per drqwing and technical specification, providing and laying of pcc m15 levelling course 150mm thick below the pile cap. ii. pcc grade m-15 (levelling course), r.c.c. grade m 35 in pile foundation complete as per dwg & tech specification. pile cap in rcc m-35, bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. ii. 1200 mm dia, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 6 mm thick as per detailed drawing., r.c.c. grade m-35 in substructure complete as per dwg & tech specification i) upto 5m height (using concrete mixer), r.c.c. grade m-35 in substructure complete as per dwg & tech specification ii) from 5m upto 10m height (using concrete mixer), r.c.c. grade m-40 in substructure complete as per dwg & tech specification ii) from 5m upto 10m height (using concrete mixer), supplying, fitting and placing hysd bar reinforcement (fe 500) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level pot-ptfe bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, ptfe surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per irc: 83 part-i & ii respectively and other parts conforming to bs: 5400, section 9.1 & 9.2 and clause 2006 of morth specifications complete asper drawing and approved technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8 i) sandy material, providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5 ii. rcc m-35, supplying, fitting and placing hysd bar reinforcement (fe 500) in superstructrue complete as per drawings and technical specification clauses 1002, 1010 & 1202, providing and laying cement concrete wearing course m30 grade including reinforcement complete as per drawing and technical specifications clauses 800 and 1206.3, provision of an reinforced cement concrete crash barrier at the bridge decks& approaches to bridge structures constructed with rein forced cement concrete with hysd r

CTN :41067144 Due date: 22 Jul, 202522 Jul, 2025 8.85 Crore
Tender For mgsy/25-26/siwan-1 /01 - high level bridge across river on const. of rcc hl bridge with approach road over sona river between pakri makriyar to chhotka manjha in block - siwan sadar , rwd division siwan-1 , district - siwan , bihar, pile load test on single vertical pile in accordance with is:2911(part-iv) including dynamic load test for its integrity , length & capacity a) initial and routine load test, pile load test on single vertical pile in accordance with is:2911(part-iv) including dynamic load test for its integrity , length & capacity a) initial and routine load test, pile load test on single vertical pile in accordance with is:2911(part-iv) including dynamic load test for its integrity , length & capacity b) lateral load test, earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. upto 3.000 m depth, providing and constructing temporary island 16 m diameter. all complete job as per specifications and direction of e/i., providing service road etc. all complete job as per specifications and direction of e/i., providing steel liner 6 mm thick for piles including fabricating and setting out as per detailed drawing., bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m., dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres(extra pile length). stripping off rcc m35 in the pile up to cut off level and disposal of debris with all leads and lifts., sand filling in foundation trenches as per drawing & technical specification, providing and laying of pcc m15 levelling course 100mm thick below the pile cap., cement concrete for reinforced concrete m - 35 in pile cap complete as per drawing and technical specification, supplying, fitting and placing un-coated hysd bar reinforcement in foundation complete as per drawing and technical specifications., providing rcc m-30 mechanically mixed concrete in abutment shaft & pier shaft with stone aggregate 20 mm nominal size and clean coarse sand of fm-2 all complete job as per design upto 5 m hieght, providing rcc m-30 mechanically mixed concrete in abutment shaft & pier shaft with stone aggregate 20 mm nominal size and clean coarse sand of fm-2 all complete job as per design beyond 5 m and upto 10m hieght, supply fitting & fixing elasto-meric bearing & seismic pad :-- supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weep holes in abutment cap with 100mm dia ac pipe:-- providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications., supplying, fitting and placing hysd bar reinforcement in substructure complete as per drawing and technical specification., back filling behind abutment, wing wall and return wall, complete as per drawing and \technical specification.(sandy material ), providing and laying of filter media with granular materials/stone crushed aggregate satisfying the requirement laid down in ci. 2504.22 of morth specification of not less than 600mm behind abutment, wing and return wall to the fu

CTN :41082911 Due date: 22 Jul, 202522 Jul, 2025 10.10 Crore
Tender For mgsy/25-26/teghra/02 - construction of h.l rcc bridge ( 6 x 18.75 m) over river balan in between pwd road to mujahidpur ( maheshpur- gehuni ghat per balan nadi par pul ) under bhagwanpur block in the district of begusarai, excavation for structures , earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. up to 3.00 m depth ., levelling course for pile cap , providing and laying of pcc m15 levelling course 100mm thick below the pile cap., providing and laying reinforced cement concrete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5 , rcc grade m -35 in pile cap, bored cast in situ piles r.c.c m-35 , pile excluding reinforcement complete as per drawing and technical specification and removal of excavated earth with all lift and lead up to 1200 m, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawing and technical specifications , tmt in foundation , refer bbs ,qty = 54.273+16.411+74.929+ 29.651= 175.264, 6mm thick. steel liner as per drawing and technical specification ., providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. well. assuming depth of water 1.0 m and height of island to be 1.25 m including royality for earth @ rs. 3768.00 for each island., pile load test on single vertical pile in accordance with is:2911(part-iv) 1985, a) initial load test @ 2.5 times load on 1 pile, c) lateral load test, confirmatory boring at abutment and pier location, back filling behind abutment, wing wall and return wall complete as per drawing and technical specification, providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of morth specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification., plain/reinforced cement concrete in sub-structure complete as per drawing and technical specificationsheight upto 5m , rcc grade m30, plain/reinforced cement concrete in sub-structure complete as per drawing and technical specifications ,rcc grade m30 , height 5m to 10m, supplying, fitting and placing hysd bar reinforcement in sub-structure complete as per drawing and technical , reinf qty = 20.810+28.454+1.762+0.313+1.289+1.139 =53.77, providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., furnishing and placing reinforced/prestressed cement concrete in super-structure as per drawing and technical specificatio,rcc grade m 30, height 5m to 10m, reinforeced cement concrete m30 grade approach slab including reinforcement and formwork complete as per drawing and technical specification, pcc m15 grade leveling course below approach slab complete as per drawing and technical specification, construction of rcc railing of m30 grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical rcc post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as

CTN :41082914 Due date: 22 Jul, 202522 Jul, 2025 4.44 Crore
Tender For (nabard)/25-26/rajauli/01 - 1) name of work: construction of hl rcc bridge over khuri river in gram panchayat bakshanda, earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. upto 3.000 m depth, providing and constructing temporary island 16 m diasmeter all complete job as per specifiactions and direction of e/l, providing service road etc. all complete job as per specifications and direction of e/i., providing steel liner 6 mm thick for piles including fabricating and setting out as per detailed drawing., bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m., dismantling of reinforced concrete pile head complete as per drawing and technical specification, providing and laying of pcc m15 levelling course 100mm thick below the pile cap., cement concrete for reinforced concrete m - 35 in pile cap complete as per drawing and technical specification, supplying, fitting and placing un-coated hysd bar reinforcement in foundation complete as per drawing and technical specifications., providing rcc m30 mechanically mixed concrete in abutment shaft & pier shaft with stone aggregate 20 mm nominal size and clean coarse sand of fm-2 .all complete job as per design upto 5 m height, supply fitting & fixing elasto-meric bearing & seismic pad :-- supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications. elastomeric bearing & pad, providing weep holes in abutment cap with 100mm dia ac pipe:-- providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications., supplying, fitting and placing hysd bar reinforcement in substructure complete as per drawing and technical specification., back filling behind abutment, wing wall and return wall, complete as per drawing and \technical specification.(sandy material ), providing and laying of filter media with granular materials/stone crushed aggregate satisfying the requirement laid down in ci. 2504.22 of morth specification of not less than 600mm behind abutment, wing and return wall to the full height compacted., providing rcc m 30 grade & super structure :--furnishing and placing reinforced/ prestressed cement concrete in super-structure as per drawing and technical specification beyond 5 m and upto 10m hieght (t beam slab), providing hysd bar in all types of rcc work:-- supplying, fitting and placing hysd bar reinforcement in super-structure complete as per drawing and technical specifications ., wearing coat :-- providing and laying cement concrete wearing coat m-30 grade including reinforcement complete as per drawing and technical specifications, providing rcc m30 grade in railing:-- construction of precast rcc railing of m30 grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical rcc post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications., providing drainage spout:-- drainage spouts complete as per drawing and technical specification, providing pcc m15 grade below approach slab:-- pcc m15 grade leveling course below approach slab complete as per drawing and technical specification, providing pcc / rcc m30 in approach slab:-- reinforced cement concre

CTN :41082915 Due date: 22 Jul, 202522 Jul, 2025 9.97 Crore
Tender For (nabard)/25-26/samastipur/01 - construction of hl rcc bridge over shanti river in chakmahesshi panchayat near chakmaheshi dhala, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.i) upto 3m depth, providing and laying of pcc m15 levelling course 100mm thick below the pile cap.ii. pcc grade m-15 (levelling course for pile cap), r.c.c. grade m 30 in pile foundation complete as per dwg & tech specification.pile cap in rcc m-30, bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m.ii. 1200 mm dia, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing, providing and constructing one span service road to reach island location from one pier location to another pier location including royality for earth @ rs. 225.00 per m for service road., carrying out load test on any pile as per standard procedure laid down in the is:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load1.2 m dia pile, b) routine pile load test on pile for 1.5 times the design load specified in drawings1.2 m dia pile (2% of piles in total)., c) horizontal pile load test on pile for 1.5 times the design load specified in drawings1.2 m dia pile (2% of piles in total) ., substructure, r.c.c. grade m-30 in substructure complete as per dwg & tech specificationi) upto 5m height (using concrete mixer), ii) from 5m upto 10m height (using concrete mixer), r.c.c. grade m-35 in substructure complete as per dwg & tech specificationrcc m-35ii) from 5m upto 10m height (using concrete mixer), supplying, fitting and placing hysd bar reinforcement (fe 415) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8 i) sandy material, providing and laying filter media with granular crushed aggregates (jhama metal) as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, superstructure, providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5ii. rcc m-30, supplying, fitting and placing hysd bar reinforcement (fe 415) in superstructrue complete as per drawings and technical specification clauses 1002, 1010 & 1202, providing and laying cement concrete wearing course m 30 grade including reinforcement complete as per drawing and technical specifications clauses 800 and 1206.3,

CTN :41059441 Due date: 21 Jul, 202521 Jul, 2025 16.50 Lacs
Tender For mgnrega re e tender fy 2025-26 - 0295 stone aggregate(single size):20 mm nominal size, 0297 stone aggregate(single size): 10 mm nominal size, 0982 coarse sand (zone iii), 0367 portland cement, 0002 hire charges of concrete mixer 0.25 to 0.40 cum with hopper, 0012 vibrator (needle type 40 mm), 7319 wall form panel 1250x500 mm, 7326 corner angle 45x45x5 mm 1.50 m long, 7327 100 mm channel shoulder 2.5 m long, 7328 double clip (bridge clip), 7329 single clip, 7330 m.s. tube 40 mm dia, 4009 mild steel tubes hot finished welded type, 1215 welding by electric plant, mr113 galvanised wire mesh of average width of aperture 1.4 and nominal dia. of wire 0.63 mm, 1219 wire nails, 1023 galvanised steel j or l hooks 8 mm dia, 1208 bitumen washer, 1209 g.i. plain washer thick, mr186 precoated aluminium trafford sheet 0.450mm thick, 0293 stone aggregate(single size):40 mm nominal size, mr2 solid block masonry of size 30x30x20cm, 1005 twisted steel bars/deformed bars, mr52 pvc pipe 75mm outer dia 6kgf/cm2, mr53 pvc pipe 75mm outer dia 4kgf/cm2, mr70 pvc bend 75mm dia

CTN :41037854 Due date: 22 Jul, 202522 Jul, 2025 9.00 Crore
Tender For mgsy/25-26/teghra/01 - construction of h.l rcc bridge ( 6 x 21.750 m) in alapur to pasopur & l021 to pakthaul , ( khijir chak abm kirtoul ke bich balan nadi par pul ) under teghra block in the district of begusarai, excavation for structures , earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. up to 3.00 m depth ., levelling course for pile cap , providing and laying of pcc m15 levelling course 100mm thick below the pile cap., providing and laying reinforced cement concrete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5 , rcc grade m -35 in pile cap, bored cast in situ piles r.c.c m-35 , pile excluding reinforcement complete as per drawing and technical specification and removal of excavated earth with all lift and lead up to 1200 m, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawing and technical specifications , tmt in foundation , refer bbs ,qty = 54.273+16.411+74.929+ 29.651= 175.264, 6mm thick. steel liner as per drawing and technical specification ., providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. well. assuming depth of water 1.0 m and height of island to be 1.25 m including royality for earth @ rs. 3768.00 for each island., pile load test on single vertical pile in accordance with is:2911(part-iv) 1985, a) initial load test @ 2.5 times load on 1 pile, b) routine load test @ 1.5 times load on 2% pile, c) lateral load test, confirmatory boring at abutment and pier location, back filling behind abutment, wing wall and return wall complete as per drawing and technical specification, providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of morth specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification., plain/reinforced cement concrete in sub-structure complete as per drawing and technical specificationsheight upto 5m , rcc grade m30, plain/reinforced cement concrete in sub-structure complete as per drawing and technical specifications ,rcc grade m30 , height 5m to 10m, supplying, fitting and placing hysd bar reinforcement in sub-structure complete as per drawing and technical , reinf qty = 20.810+28.454+1.762+0.313+1.289+1.139 =53.77, providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., furnishing and placing reinforced/prestressed cement concrete in super-structure as per drawing and technical specificatio,rcc grade m 30, height 5m to 10m, reinforeced cement concrete m30 grade approach slab including reinforcement and formwork complete as per drawing and technical specification, pcc m15 grade leveling course below approach slab complete as per drawing and technical specification, construction of rcc railing of m30 grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical rcc post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space b

CTN :41037844 Due date: 22 Jul, 202522 Jul, 2025 13.03 Crore
Tender For mgsy/25-26/balia/01 - construction of h.l rcc bridge ( 8 x 21.750 m) in between t01 se sonwarsha path under shamho akha kurha block in the district of begusarai, excavation for structures , earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. up to 3.00 m depth ., providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per drawing and technical specification. as per morth clause no. - 1200&, plain cement concrete in open foundation complete as per drawing and technical specifications pcc grade m -15 below abutment well cap, providing cement concrete /reinforced cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification rcc m-35 in well curb, providing plain cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification , pcc m-25 in well bottom plug, providing cement concrete /reinforced cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification , rcc m-25 in well steining, providing plain cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification , pcc m-25 in well intermediate plug, well sinking as per technical specification, depth 0.00m to 3.00 m (clay soil), depth 3.00m to 10.00 m (sandy soil), depth 10.00m to 20.00 m (sandy soil), depth 20.00m to 30.00 m (sandy soil), for 7.00 m dia well :; pier, depth 0.00m to 3.00 m (clay soil), depth 3.00m to 10.00 m (sandy soil), depth 10.00m to 20.00 m (sandy soil), depth 20.00m to 30.00 m (sandy soil), sand filling in wells complete as per drawing and technical specifiction. as per morth clause no. - 1207, providing cement concrete /reinforced cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification , rccm-35 in well cap, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawing and technical specifications , tmt in foundation , refer bbs ,qty = 67.622+155.612 =223.234 t, confirmatory boring at abutment and pier location, back filling behind abutment, wing wall and return wall complete as per drawing and technical specification, providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of morth specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification., plain/reinforced cement concrete in sub-structure complete as per drawing and technical specificationsheight upto 5m , rcc grade m30, plain/reinforced cement concrete in sub-structure complete as per drawing and technical specifications ,rcc grade m30 , height 5m to 10m, supplying, fitting and placing hysd bar reinforcement in sub-structure complete as per drawing and technical , reinf , qty = 23.851+24.330+1.762+0.313+1.289+1.139 =, providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., furnishing and placing reinforced/prestressed ceme

CTN :41058941 Due date: 01 Aug, 202501 Aug, 2025 25.00 Lacs
Tender For annual percentage rate contract on mes ssr 2020 for joinery,masonry, plumbing,sanitary, fabrication and cement concrete, painting and connected works in type-iv bungalows in west land estate at ofk.

Central Government/Public Sector

CTN :41055247 Due date: 23 Jul, 202523 Jul, 2025 35.48 Lacs
Tender For tender for supply of street light at mvi airport ayodhya dham - supply of bakelite sheet with 1nos of 6a dp mcb and stud type connector suitable for 4cx 6sq mm cable complete as required. , supply of 25w led street light luminiare with pre die cast aluminium housing and ip 66 protection , pf greater than equal to 0.95 , thd less than 10 percent , cri greater than equal to 70 as per technical specification complete as required. , supply of lt power cable of 1.1 kv grade of following sizes aluminium conductor xlpe insulated pvc sheathed armoured cable confirming to is 7098 part-i-1988 with upto date ammendment as required. a) 3.5 c x 95 sq. mm , supply of lt power cable of 1.1 kv grade of following sizes copper conductor xlpe insulated pvc sheathed armoured cable confirming to is 7098 part-i-1988 with upto date ammendment as required. 4c x 6sq.mm(copper conductor) , supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket , bend , couplers etc. conforming to is 14930 , part ii complete with fitting and cutting , jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. a) 63 mm dia (od-63 mm & id-50 mm nominal) , laying of one number pvc insulated and pvc sheathed/xlpe power cable of 1.1kv grade of following size in the existing rcc/gi/hume/metal/hdpe pipe etc. as required. a) above 35sq.mm and up to 95 sq mm , laying of one number pvc insulated and pvc sheathed/xlpe power cable of 1.1kv grade of following size in the existing rcc/gi/hume/metal/hdpe pipe etc. as required. b) up to 35 sq mm , supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. a) 3.5c x 95 sq.mm , supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. b) 4c x 6sq.mm(copper conductor) , itc of gi octagonal pole of following length in reinforced cement concrete 1 ratio 2 ratio 4 (1 cement 2 coarse sand 4 stone aggregate 40mm nominal size) foundation i/c excavation and refilling etc. complete as required a) 5 mtr. height , itc of 30w led street light luminiare on existing pole bracket i/c connection with 1.5sq.mm frls copper wire complete as required. , earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. , providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut , bolt , spring , washer excavation and re-filling etc. as required. , earthing with g.i. earth pipe 4.5 metre long , 40 mm dia including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. , providing and laying earth connections , from earth electrode with 6 swg dia , g.i wire in 15mm dia , g.i pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. , providing and fixing 6 swg g.i. wire on surface or in recess for loop earthing alongwith the existing cable as required. , design , fabrication , supply , installation , testing & commissioning of outdoor feeder pillar , cubicle type , made out of 2 mm thick crca sheet , totally enclosed , ip 55 , free standing , floor mounting , dust and vermin proof , indoor , compartmentalised , suitable for operation on 3 phase and neutral , 415 v , 50 hz ac system , including internal wiring with suitable size wires/cable , interconnection , duly powder coated painting etc. , including supply & insta
 Loading, Please wait...

Connect us via What's Up