Get complete information related to latest Centre Table Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Centre Table Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Centre Table Tenders.
Tender For supply of following items for setting up measurement and instrumentation lab for 4 year b.tech in electrical engineering curriculum and application for university of calcutta. - experimental set-up for calibration of a wattmeter using dc potentiometer with following features/items:regulated power supply 2 volts, 100 ma to operate the potentiometer.calibrated electronic standard cell voltage 1.0186 volts.regulated power supply 0-5 volts/0.5 amps with milliammeter 0- 500ma for current coil of wattmeter.regulated high voltage power supply 0-250 dc volts with voltmeter 0-250 volts for pressure coil of wattmeter.a panel mounting wattmeter 0-125 watt is required to perform the experimentgalvanometer for null balance.a volt ratio box for measurement of higher voltage.complete circuit diagram with wattmeter connections to be provided on the front panel of the instrument.with standard accessories, experimental set-up for low resistance measurement using kelvin s double bridge with following features:range: 0.2 micro ohm to 11 ohms, with an accuracy of 0.05 %required accessories:spot reflecting galvanometer. dc source 10 a with one analog current meter. attachment of 1 meter length.brass clamp with terminals for zero setting. with standard accessories, experimental set up for unknown capacitance measurement using de-sauty s bridge with following specifications:source: sine wave signal of 1khz. the amplitude of ac switch indicating lamp is provided on the bakelite board. two sockets are to be provided for the output of ac signals.detector: for detecting small ac signals in the output, null detector is required as in-built with digital display.circuit diagram:the circuit layout on the board is to be provided out to facilitate convenient working. 4 or 5 mm socket required for making connection. features:r2 --- three decade resistance dials having value 10 1000, 10 100 and 10 10 ohmsr1 ---- single decade resistance dial having value 10 100 ohmsc1 ---- unknown capacitor.c2 ---- two fixed standard capacitors having value 0.01mfd 0.1mfd (loss free)with standard accessories, experimental set-up for calibration of a 1-phase watt-hour meter with following scopes: to adjust & calibrate a single-phase energy meter by direct loading method to adjust & calibrate a single-phase energy meter by comparing with a sub-standard meterspecifications: static energy meter single phase: under test (local) duly mounted, wired and terminated static energy meter single phase: sub-standard meter (isi mark) duly mounted, wired and terminated voltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v ac ammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a ac wattmeter: dynamometer type ac single phase, multi-range with current coil 5 / 10 amp and potential coil 75 / 150 / 300 v ac variac: variable voltage transformer (portabletable / floor mounting type with enclosure) input: 230v ac and output: 0 270v / 8 amp ac variable load: made up of 3 load resistors of 70 ohms / 700 w each duly mounted and connected / terminated to form different loads (35 to 210 ohms) as per external connections digital stop clock: portable with start / stop & reset operation set of necessary 4 mm spring loaded patch cords for interconnections detailed instruction manual supply to be connected: 230v, 1phase, 50 hz, ac mains, experimental set-up for calibration of a 3-phase watt hour meter with following specifications: to adjust & calibrate a three-phase energy meter by direct loading method to adjust & calibrate a three-phase energy meter by comparing with a sub-standard meterspecifications:static energy meter three phase: under test (local) duly mounted, wired and terminatedstatic energy meter three phase: sub-standard meter (isi mark) duly mounted, wired and terminatedvoltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v acammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a acwattmeter: