Tender For corrigendum : repair/renewals of capacitor panel, control panel, capacitor bank, earthing, lt panel, relay associated switch gear and allied works at zone iia and iid under age em ii of ge (u) secunderabad
Tender For supply of electrical items c c - 1.5 sq. mm isi marked, frls orhffr pvc insulated, single core copper conductor cable , 2.5 sq. mm isi marked, frls or hffr pvc insulated, single core copper conductor cable , 4.0 sq. mm isi marked, frls or hffr pvc insulated, single core copper conductor cable , 6.0 sq. mm isi marked, frls or hffr pvc insulated, single core copper conductor cable , modular base and cover plate for 4 modules , modular base and cover plate set for 8 module , modular base and cover plate set for 12 module , s.p. 5a or 6 a, one way modular switch, isi marked , s.p. 15a or 16 a, one-way modular switch, isi marked , 3 pin 5a or 6 a modular socket outlet, isi marked , 6 pin 15a or 16 a modular socket outlet, isi marked , stepped type modular fan regulator 2 module , 2 plus 2 way spn single door mcb db , 8 way 4 plus 24, tpn, mcb db, double door, horizontal type , 25 a, ratings, sp mcb, c curve, 10 ka breaking capacity , 4 pole mccb, 125a, 36ka ics equal to 100 percent icu and operational voltage 690v , 4 pole mccb,250a, 36ka ics equal to 100 percent icu and operational voltage 690v , led batten light system lumen efficacy greater than 105 or less than 120 lm per watt of materials crca sheet body thickness greater than 0.50 mm 18-22 watt , led panel light 2x2 ft. system lumen efficacy greater than 105 or less than 120 lm per watt of materials crca sheet body thickness greater than 0.50 mm 45 watt , led down lighter cob type system lumen efficacy 120 lm per watt powder coated die cast or extruded aluminium body including trim with aluminium reflector, 12- 15 watt , led down lighter smd type system lumen efficacy greater than 135 lm per watt powder coated die cast or extruded aluminium body including trim with aluminium reflector 12 -15 watt , led flood light, powder coated pressure die cast aluminium system lumen efficacy greater than 135 lm per watt 100 watt , led flood light, ) /bid number : gem/2026/b/7232088 * /dated: 12-02-2026 & & / bid document 1 / 44 & & ' ' /item category powder coated pressure die cast aluminium system lumen efficacy greater than 135 lm per watt 250 watt , aluminium lugs for 120 sq. mm cable , aluminium lugs for 95 sq. mm cable , aluminium lugs for 50 sq. mm cable , aluminium lugs for 35 sq. mm cable , straight through cable jointing kit with cast resin compound with ferrules for 3.5 x 95 sq. mm 1.1 kv grade cable , 2.5 sq mm, 3 core, multi-strand copper wire of 90 mtr length , 4 module pvc box , 8 module pvc box , 12 module pvc box , ac box with 25 a mcb and top , 63 a triple pole, type c mcb, 220 v , 63 a four pole, type c mcb, 220 v , suitable enclosure box , 9 watt led bulb , 18- watt led bulb , flood light 30 watt, 220-240 v , 100 a changeover, 4 pole with enclosure box and handle, 415v , 250 a changeover, 4 pole with enclosure box and handle, 415v , starter for 3 hp single phase submersible with enclosure ip 65, 50hz, 240v , smf battery 12v 7ah, , 10 sq mm 2 core aluminium unarmoured cable , 10 sq mm 2 core aluminium armoured cable , 95 sq mm, 3.5 core, xlpe aluminium armoured cable in rmt , 185 sq mm , 4 core end termination kit lt -out door use , rachit set tool kit 22 sockets of size 8 mm, 9 mm,10mm,11mm, 12 mm, 13 mm, 14 mm, 15 mm, 16 mm, 17 mm, 18 mm, 19 mm, 21 mm, 22 mm, 23 mm, 24 mm, 26 mm, 27 mm, 28 mm, 29 mm, 30 mm, 32 mm , metal anchor fastner 8 mm , metal anchor fastner 10 mm , 6.0 mm dia. and 160 mm length hammer drill bit , 4 inch dia metal cutting blade , 5 inch dia wall cutting blade , electrical safety shoes 8 number pair , electrical safety shoes 9 number pair , hand gloves pair type 2 - for use at voltage not exceeding 1100 ac rms , 2.5 mfd fan capacitor , 45 plus 4 mfd capacitor , 1.5 inch screw , self-adhesive pvc electrical tape 7 mtr , 20 mm casing caping pvc 3 mtr approx of length, single lock , casing caping clip , 20 mm pvc tee , 20 mm iron saddles , 25 mm iron saddles , pvc fastner 40mm long , 20 mm dia, isi marked, pvc conduit , 25 mm dia, isi m
Tender For arm electrical works esic and esis campuses at thathaneri, ponnagaram, maninagaram under madurai region for a period of 12 months - engaging of 1 no charge electricean having c licence holder of day to day maintenance of electrical maintenance works and to monitor these works are properly attended and to take care of complaints arised related to repairs / replacement of damaged fittings / fixtures in the campus such as switches, sockets, switch boards, ht/lt panels , mcbs, mcb dbs, mccbs, sfus, fsus etc., and all types of fans / light fittings, ug cables etc., complete all as directed by the engineer-in-charge. ( 01 no.) (qualification: diploma in electrical engineering with 10 years related experience/iti with 12 years or experience (supervisory) in maintenance job) (qualification: iti certificate with 03 years experience in operation of 11kv / 415v substation and equipment and dg sets along with valid 11kv /415v supervisor permit /c- certificate/grade c-license holder) (higly skilled). he is resposonsible to maintain & update the all logbook of preventive maintenace e&m equipment(lifts,panels,substation,dg sets,fire equipment,ro,stp&etp etc...) with respective staff.[1 no c licence holder ( highly skilled)]. note:-1. he is the responsible for ht metering cubicle to monitor & maintain all parameter readings.2. he is the responsible for timely calibration of ht vcbs, lt acbs/mccbs and earth fault relays and over current relays.3. he is the responsible for ht panels, transformers, acbs, mccbs, apfc panels with connected capacitor banks, power contactors & relays, up keep & maintain records for earth results in the ht & lt installations as per the direction of engr-in-charge.4. during main eb supply failure to monitor the running of stand by dg sets and maintain the plant running record book with all parameters and earth test register & insulation test register, fire alaram, smoke detection and fire fighting register all as directed.5. to maintain the eb shutdown register & obtain the necessary signature from eb authorities . (it should be talley with stand by dg set prrb), engaging lift operator cum electrician for day to day ( 1 shift /day in gen shift) lift operator is responsible for the safe operation of elevators/ lifts.checking of lift condition, to carry out rescue operation and following up with oem for pm & break down calls etc.., to make it in proper working condition etc.., here are some common duties and tasks associated with this roleof lift operator is to assist passengers in safely while loading and unloading and to ensure the safety and comfort of passengers during lift operations.maintenance: operators maintain the lift area, keeping it clean and organized. they also implement emergency procedures when necessary.evacuation: in case of disabled lifts or emergencies, lift operators evacuate passengers as per established protocols.qualification of lift operator: iti electrician with 3 years experience operation & maintain of lifts.- 1 nos (01 lift operator cum electrician for esih thathaneri), engaging electrician cum substaion attendant cum dg operator cum panel opearator for day to day ( in 3 shifts /gen shift) operation of substation, dg sets, lt panels , mcbs, mcb dbs, mccbs, sfus fsus etc and maintenance of electrical works like repairs to internal and external electric supply by replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, lt panels , mcbs, mcb dbs, mccbs, sfus fsus etc and all types of fans/ light fittings, oh lines, ug cables, dg set etc complete all as directed by the engineer-in-charge. and maintain logbooks along with shift register to be updated daily etc to be maintained as directed by engineer-incharge..electrician skilled (iti certificate with 3 years experience)- 4 nos note:1. he will maintain the shut down cum log book register and duly enter all the parameters.2. duri