Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
Tender For providing of repair and overhauling service - repairing work of exhaust muffler thermal insulation cover of under slung engine of tc2 bdgm rake and provision of schaku coupler housing work; repairing work of exhaust muffler thermal insulation cover of under slung..
Tender For corrigendum : thermal insulation works pertaining to boiler and its auxiliaries of unit-ii, rgtpp and thermal insulation works on turbine, pipelines, valves etc. of unit-ii during overhauling at rgtpp, khedar, hisar.
Tender For supply of re-useable thermal insulation pads made with high temperature binder-less fiber mat and , 2. supply of adhesive tape for installation of re-useable thermal insulation pads (item no: -1) made
Tender For corrigendum : supply of thermal insulation for exhaust pipes and fitting c c - thermal insulation for exhaust pipes fittings main engine exhaust , service for thermal insulation of exhaust pipes fittings main engine exhaust , thermal insulation for exhaust pipes and fittings main diesel generator exhaust system , service for thermal insulation of exhaust pipes and fittings main diesel generator exhaust system , thermal insulation for exhaust pipes and fittings incinerator exhaust system , service for thermal insulation of exhaust pipes and fittings incinerator exhaust system , thermal insulation for exhaust pipe emergency air compressor exhaust system , service for thermal insulation of exhaust pipes and fittings emergency air compressor exhaust system , thermal insulation for exhaust pipes and emergency dg exhaust system , service for thermal insulation of exhaust pipes and fittings emergency dg exhaust system , thermal insulation for exhaust pipes and emergengy fire pump exhaust system , service for thermal insulation of exhaust pipes and fittings emergengy fire pump exhaust system , thermal insulation for exhaust pipes hot pipes and fittings , service for thermal insulation of exhaust pipes and fittings hot pipes and fittings , thermal insulation for exhaust pipes miscelleneous , service for thermal insulation of exhaust pipes and fittings miscelleneous
Tender For supply of moulded case circuit breaker[mccb],4-pol [moulded case circuit breaker[mccb],4-pole, rated current 63a,rated voltage 415v,50hz,3-phase ac,conforming to is:13947[pt 1&2]/iec 60947- 1&2,breaking capacity 25ka,insulation voltage 690v ac or higher,capable to withstand 50 degree c ambient temperature, fitted with adjustable thermal magnetic overload release and fixed magnetic short circuit release,impulse withstanding voltage capacity of 8kv or higher,fitted with rotary handle for operation having indication of on/off/tripped with locking arrangement in off position to avoid accidental on position, maximum overall mechanical dimension of]