Get complete information related to latest Ceramic Item Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ceramic Item Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ceramic Item Tenders.
Tender For corrigendum : day to day and urgent emergency repair and maintenance work at rhtc digod and hostal (including civil work, joinery work, sanitary work, painting work,supply of labour,supply of material etc.)
Tender For corrigendum : day to day and urgent emergency repair and maintenance work at chc sultanpur (including civil work joinery work, sanitary work, painting work,supply of labour,supply of material etc.)
Tender For set of dc mcb used in switch board cabinet (sbc) of lhb ac coaches. a set contains 01 nos of 6a mcb 2p 200vdc, 01 nos of 16a mcb 2p 200vdc, 01 nos of 10a mcb 200vdc, 01 nos of 2.5/3a mcb 2 00 vdc, 01 nos of 6a sp mcb 200vdc i.e. 5 items & 5 in nos. as per rdso specification no. rdso/pe/ spec/ 0184-2015 (rev-1) or latest. material make is abb/ l&t/ schneider/ eaton/ siemens only. material procures from oem or his authorized dealers only. details are as follows: 1) mcb for main light/reading light/ dc- dc c onverter etc rated current 6a, rated voltage 200 vdc, 2 pole, 10 ka breaking capacity. material is m/s l&t part no. bj2006dc or m/s siemens part no. 5sy52067cc or m/s abb part no. s202mtc6uc or m/s eaton par t no. faz-c6/2dc or m/s schneider part no. a9n61526. 2) mcb for lightcontactor rated current 16a, rated v oltage 200 vdc, 2 pole, 10 ka breaking capacity. material is m/s l&t part no. bj2016dc or m/s siemens par t no. 5sy52167cc or m/s abb part no. s202mtc16uc or m/s eaton part no. faz-c16/2dc or m/s schneider part no. a9n61531. 3) mcb for power supply/ sanitary control pasystem etc rated current 10a, rated voltag e 200 vdc, 2 pole, 10 ka breaking capacity. material is m/s l&t part no. bj2010dc or m/s siemens part no. 5sy52107cc or m/s abb part no. s202mtc10uc or m/s eaton part no. faz c10/2dc or m/s schneider part n o. a9n61528. 4) mcb for ventilation fan/cdfan/compressor etc 2.5/3a, rated voltage 200 vdc, 1 pole, curv e c, 10 ka breaking capacity. material is m/s l&t part no. bj1003dc or m/s siemens part no. 5sy51037cc o r m/s abb part no. s201m-c3uc or m/s eaton part no. faz-c3 dc or m/s schneider part no. a9n61503. 5) m cb for anti skid device rated current 6a, rated voltage 200 vdc, 1 pole, 6/10 ka breaking capacity. material is m/s l&t part no. bj1006dc or equivalent part no of m/s siemens or m/s abb part no. s202mtc6uc or m/s eaton part no. faz-c6 dc or m/s schneider part no. a9n1p06d.note: firm should supply proof of purchase f rom oem or authorized dealers only. firm should supply test certificate & guaranty certificate along with su pply of item. accepted make/brand- siemens. (warranty period : upto 30 months from the date of delivery. ) note: this item should be procured from oem/authorized dealer only. [ warranty period: 30 months afte r the date of delivery ]
Tender For corrigendum : periodical services(internal) including repairs to flooring,sanitary and plumbing items works in otm and md accn at ridge, raulki area under age b/r-i of ge satwari - notes : (1) work will be carried out upto 4th storey of bldgs and quoted rates of items shall be deemed to include the cost of necessary formwok and scaffolding required as per site conditions., taking down shutters of any description exc 1.00 sqm and not exc 2.00 sqm each and removing from the site complete all as specified & directed., taking down chowkats or frames with shutter (without taking off shutter from the frame) n. exc 1.5 sqm each including cutting holes for taking out hold fast or dismantling brick work and removing from site complete all as specified and directed., taking down chowkats or frames with shutter (without taking off shutter from the frame) exc 1.5 sqm & n. exc 4 sqm each including cutting holes for taking out hold fast or dismantling brick work and removing from site complete all as specified and directed., demolition of cement concrete (un-reinforced) in ground floor to 4th floor and pavings n exc 15 cm thickness (below or above ground level ) and removing the rubbish from the work site to out side defence premises complete all as specified and directed., demolition of concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed., taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubing down with water etc and removing unserviceable material outside defence land complete all as specified and directed., dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed, s&f pressed steel frames of size 125mm x 60 mm made out of size 1.25 mm thick ms sheet for doors with one or more rebates including mild steel hinges, 100 mm long , medium weright and 25 mm x 3 mm flat iron as in hold fast , tie bar including necessary fixing lugs, lock strike plate and fixing arrangement and making good the disturbed surfaces in cement mortar 1:3 or cement concete 1:2:4 type b-1 including pcc 1:3:6 type c1 as in back fill to chowkats complete all as specified and directed., s&f pressed steel frames of size 105mm x 60 mm made out of size 1.25 mm thick ms sheet for doors with one or more rebates including mild steel hinges, 100 mm long , medium weright and 25 mm x 3 mm flat iron as in hold fast , tie bar including necessary fixing lugs, lock strike plate and fixing arrangement and making good the disturbed surfaces in cement mortar 1:3 or cement concete 1:2:4 type b-1 including pcc 1:3:6 type c1 as in back fill to chowkats complete all as specified and directed., s&f 35 mm thick factory made 2nd class hard wood, plain, framed, panelled shutters (two panels) with lock rail and panel of 9mm thick bwp commercial plywood .the size of rail and stiles as per is: 1003(part-1), kiln seasoned and chemically pressure treated, fitted to chowkats complete all as specified and directed., s&f factory made 35 mm thick 2nd class hard wood, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in ssr part i, section 8, clause 8.24 (a); fitted to chowkats complete all as specified and directed, m&l for 30mm thick factory made flush shutters, solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed., s&f in repair solid pvc door frame of size 50mm x47mm made out of 5mm plain colour pvc sheet reinforced with mild steel square tube, supplying and fixing in opening