Web Analytics Made Easy - StatCounter

Ceramic Plug Tenders

Get complete information related to latest Ceramic Plug Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ceramic Plug Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ceramic Plug Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40966272 Due date: 21 Jul, 202521 Jul, 2025 18.15 Lacs
Tender For procurement of electrical materials for regular electrical maintenance works in all floors of sldc building, ground, first & second floors of main building vidyut soudha and ground & first floors of appcc building in vidyut soudha premises, vijayawada.(re-call) - supply of 36 wrecessed / surface mounting 2' x 2' (600x600 mm) led luminaire made of crca sheet housing with powder coated with acrylic diffuser, constant current driver as per is: 15885 (part 2/ sec 13) : 2012 , with operating voltage range of 150 to 265 volts ac, p.f > 0.9, surge protection: 2kv, thd<10%, with high power leds, having system efficacy of >=100 lumens / watt, cct: 3000k - 5700k, minimum cri>70, .etc., complete crompton make., supply of 22 w led slim panel round /square suitable for recessed / surface mounting made of diecast aluminum body with powder coating, acrylic diffuser with driver as per is: 15885 (part 2/ sec 13) : 2012, operating voltage range of 150 to 265 volts ac, p.f > 0.9, surge protection: 2kv, thd<10%, with high power leds, having system efficacy of >=100 lumens /watt, cct: 3000k - 5700k, minimum cri>70, .etc., complete crompton make., supply of 18 w led slim panel round /square suitable for recessed / surface mounting made of diecast aluminum body with powder coating, acrylic diffuser with driver as per is: 15885 (part 2/ sec 13) : 2012, operating voltage range of 150 to 265 volts ac, p.f > 0.9, surge protection: 2kv, thd<10%, with high power leds, having system efficacy of >=100 lumens /watt, cct: 3000k - 5700k, minimum cri>70, .etc., complete crompton make., "supply and transportation of150w led street light luminaire made of pressure diecast aluminum body with powder coated, having protective toughened glass, supply input voltage 120 - 270v ac, p.f > 0.90, high power leds having system efficacy >= 120 lumens/watt and junction temperature < 70c, with ingress protection ip66, luminaire performance complies to is 10322 (part 5/sec-3), driver surge protection 4kv, in-house additional surge protection 10 kv with optics distribution, thd<10% at 110 volts ac, driver efficiency >90%, cct: 3000k - 5700k, minimum cri>70, etc., complete with earth connection and not less than two years warranty. a) luminaire make : wipro(skyline) / philips (greenline extra) / ge- venture / crompton(nexus / hawk series) / bajaj (edge) / halonix (modular/ lumos-super) / havells (endura series)/greenlites(hi-lux) /capart(premium)/polycab/keselec / hpl(city vision)/jaquar (premium) /eveready /surya (pollux) / fortune arrt (leaf) / rhino(gpsl06) b) led make :philips lumileds / cree / nichia / osram / samsung / lg.", supplyof 24w, not less than 1100mm length led batten light with extruded aluminum housing and polycarbonate cover, input voltage ac 220 - 260 volts, with high power leds, having system efficacy of >=100 lumens/watt , pf>0.9, surge protection: 2kv, thd<15%, with inbuilt driver and frosted cover cct: 3000k - 5700k, minimum cri>70, etc., complete crompton make., supply and transportat of led 18 w stylus surface led light slim panel round /square ., supply of 16" (400mm) wall mounted fan.makes: crompton wind flo / bajaj elite / havells swing / orient wall 50/halonix krypton/g.m. (bolt)/ goldmedal(nora-16), "supply of 16"" (400mm) pedestal fan. makes: crompton wind flo / bajaj spectrum / havells swing / orient stand 37/halonix krypton/polycab / g.m. (bolt)/goldmedal(nora-16)", supply of 48" (1200mm) sweep 5 star rated bldc (brush less direct current) ceiling fan with double ball bearings, input voltage 230v ac converted to 24 v dc, power input not more than 30w, air delivery not less than 220 cubic meter/min and a minimum service value of 7.0, with remote and without regulator. makes: atomberg(gv2 )/ halonix(plasma) /havells(efficiencia neo)/ crompton(en groove)/superfan(e281)/rjp(ecowise), supply of 15" (375mm) isi, 900 rpm heavy duty exhaust fan with metallic blades with isi mark.makes: crompton / almounard / havells turbo force/halonix krypton, su

State Government

CTN :40985778 Due date: 28 Jul, 202528 Jul, 2025 1.80 Crore
Tender For purchase of sports physiotherpy lab equipments - focused shockwave therapy the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high laser therapy should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser power output of 15 watts should have wavelengths of 810 nm & 980 nm should have an aiming beam of 650nm, should have 2 operating modes: continuous wave or pulsed applicate and piece should have embedded finger switch and light, should have a technology to customize patient treatment based on conditions, body area, body type, skin type, chronicity and absorption characteristics applicator should have a fused silica composition massage ball at the point of contact of applicator and skin. pulse frequency: 2, 10, 20, 100, 200, 500, 1000, 2500, 5000 & 10000hz pulse duration: 50% duty cycle at any given pulse frequency setting, should have a 10 hd display touch screen with password protection to reach the home screen should be supplied with 2nos. of laser protection glasses power: 100-240v, 50-60 hz the unit should be supplied with 5 different types and sizes of treatment heads (large cone, large massage ball, flat window, small massage ball, and small cone. the unit should have inbuilt battery. electrical safety class: class i, type b weight should not exceed 4 kilograms (main unit; without applicators & accessories. must have class iii also., combination therapy machine with vaccum should have 3 independent electrotherapy channels, one ultrasound channel should provide multiple clinical waveforms including interferential (2 and 4 poles and isoplanarvector), tens (asymmetric biphasic &symmetric biphasic), han, russian, vms, surged(rectangular &triangular), hvpc, microcurrent, galvanic (continuous, interrupted and low level),rabert & dia dynamic cpid/cpiso should have independent parameter adjustments for each channel including intensity, frequency, duty cycle, vector scan, channel mode, phase duration, ramp, cycle time and treatment time based on waveform should have maximum output intensity up to 140ma should have constant current and constant voltage modes should have 2 colour coded lead wires for easy picking of selected channels should have suggested electrode placement guidelines ultrasound should offer 1 and 3 mhz frequencies should have the ultrasound bnr of 5:1 or lesser should be supplied with one 5cm applicator head should have pulsed & continuous frequency modes (10%, 20%, 50% & 100%) should have variable duty cycles of 16 hz, 48 hz &1 bb 00 hz should have facility to indicate applicator uncoupling should be able to use electrotherapy and ultrasound independently and also in synchronizedcombination of electrotherapy and ultrasound, where ultrasound head functioning as bothultrasound head and electrode should have minimum 7 high resolut

Central Government/Public Sector

CTN :40974363 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; electrical system or installation, design, supply, installation and commissioning of diffrential protection system; service provider

State Government

CTN :40977598 Due date: 28 Jul, 202528 Jul, 2025 NA
Tender For supply of sitc of pigtail ofc - 1 meter , sitc of cat-6a cable , sitc of 19 inch 6 u rack , sitc of lan system , sitc of liu 12 port , sitc of patch cord cat-6 -1 meter , sitc of patch cord cat-6 -2 meter , sitc of patch cord cat-6 -10 meter , sitc of hdpe pipe , supplying and fixing io box alongwith base and cover plate , sitc of cctv camera with night vision - 5 mp , supply and fixing of cat-6 wire in pvc conduit , sitc of cctv camera , fire work sitc talk back slave station , sitc smoke detector with built in led , sitc 6 kg powder type fire extinguishers , citc 2 kg powder type fire extinguishers , sitc addressable manual call point complete as required. , civil works as per boq , cement work as pe boq , providing and laying in position cement concrete of specified grade , double charge vitrified tiles , centering and shuttering , steel reinforcement for r.c.c. work , smooth finishing of the exposed surface of r.c.c. work , brick work with common burnt clay , 12 mm cement plaster of mix , partition upto ceiling height , cement fiber board , frames of doors, windows, clerestory windows , isi marked flush door shutters , universal hydraulic door closer , structural steel work , polishing in high gloss matt finish melamine , bright finished brass hanging type floor door stopper , false ceiling with cove and design at all height , removing dry or oil bound distemper, water proofing cement paint , providing and applying white cement based putty , wall painting with acrylic emulsion paint , 2mm thick pvc mat finished on floor of approved design , ac duct made of wooden batten , sitc of vertical blinds , electrical works , wiring for light point etc , wiring for circuit , supplying and fixing following modular switch etc , supplying and fixing following modular switch socket , supplying and fixing following modular switchs , supplying and fixing modules , supplying and fixing following way , supplying and fixing miniature circuit breaker , miniature circuit breaker suitable for inductive load , supplying and fixing single pole blanking plate , supplying and fixing of following sizes of medium class pvc conduit , supplying and fixing suitable size gi box wih modular plate , frls pvc insulated copper conductor , frls pvc insulated copper conductor 2 , frls pvc insulated copper conductor3 , frls pvc insulated copper conductor,4 , 3x2.5 mm flexible wire for connection , wiring for group controlled , led 2x2 luminaire 36w , recess mounted led downlighter , wall fan with brush less direct current bldc motor , electrical earthing sitc crs radio station transmitter of 50 w fm set , sitc of self supported transmission tower , vhf transmitting antenna , low loss feeder cable with n connector , studio monitor (speaker) , on-air broadcast console/mixer with inbuilt phone in unit and usb , dynamic cardioid microphone , portable solid state field recorder , headphones , broadcast audio processor , dummy load with connector , extra lightening protection circuit , 19 equipment rack ht. 5 ft , mts/equivalent, work station with antivirus for 3 years , audio editing software , automation/scheduling software licence, condensor microphone with wind filter and arm stand , audio distribution amplifier , headphone distribution amplifier , 10 kva online ups with 30 minutes back up online iso certified, xlr 6 microphone junction box , professional audio/line cable , professional microphone cable , xlr connecter male and female, trs stereo connecter , professional on air studio light , digital clock with time , supply and fixing of work station table , supply and fixing of vob table , supply and fixing of discussion table l shape, supply and fixing of on air table and side table , supply //bid details 2 / 87

corporations/Associations/Others

CTN :40968680 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For complete servicing and overhauling along with allied electrical works for protection system of 500kva (6kv/433v) oil type transformer at jinjira bazar mps under grbu.

Central Government / Public Sector

CTN :40780815 Due date: 23 Jul, 202523 Jul, 2025 NA
Tender For corrigendum : secunderabad division electrical maintenance department - sw - i sc- upgradation of existing prs data centre at secunderabad for hosting disaster recovery site of next generation e-ticketing (nget) system. sw- ii - replacement of automatic fire alarm and fire protection system and rodent repllent system at drdc centre- prs/sc.

Central Government / Public Sector

CTN :40960271 Due date: 23 Jul, 202523 Jul, 2025 NA
Tender For secunderabad division electrical maintenance department - sw - i sc- upgradation of existing prs data centre at secunderabad for hosting disaster recovery site of next generation e-ticketing (nget) system. sw- ii - replacement of automatic fire alarm and fire protection system and rodent repllent system at drdc centre- prs/sc.

CTN :40962677 Due date: 21 Jul, 202521 Jul, 2025 72.00 Lacs
Tender For supply of wheatstone bridge , wiens bridge , lab grade calibration set , power devices io fet igbt , 1 ph hw scr thyristor rectifier , 1 ph fw full bridge scr thyristor rectifier , 1 ph fw scr thyristor semi controlled rectifier , 3 ph hw scr thyristor rectifier , 3 ph fw scr thyristor controlled rectifier , 1 ph half bridge inverter , 1 ph full bridge inverter , 3 ph full bridge inverter , 3 ph 3 level diode clamped inverter , 1 ph to 1 ph cycloconverter , 3 ph to 1 ph cycloconverter , 3 ph to 3 ph cycloconverter , buck converter , boost converter , buck boost converter with variable r r l load , transmission line model , string efficiency measurement calculation model , dc ammeters , ac ammeters , lpf wattmeter , upf wattmeter , digital storage oscilloscope , mcb miniature circuit breaker , over current relay testing system , under voltage over voltage relay testing system , industrial electrical protection training system , earth fault relay testing system , high voltage power electronics lab , radial and ring main distribution system , symmetrical and unsymmetrical fault demonstrator , function arbitrary waveform generators , dual tracking fixed power supply , cathode ray oscilloscope , dsb ssb am transmitter , dsb ssb am receiver , frequency modulation and demodulation , am fm radio receiver , synchronous am detector , pcm generation demodulation , delta adaptive delta sigma delta modulator demodulator , data formatting carrier modulation transmitter , carrier demodulation data reformatting receiver , qpsk oqpsk dqpsk modulator demodulator , digital communication training system , sampling and reconstruction techniques , 8051 development board ) /bid number : gem/2025/b/6390980 * /dated: 04-07-2025 & & / bid document 1 / 49

CTN :40963151 Due date: 10 Jul, 202510 Jul, 2025 NA
Tender For supply of driven plate for clutch , housing friction clutch , armature motor , regulator engine generator , water pump assy , hose fuel , solenoid electrical solenoid , parts kit slave cylinder clutch , ball bearing , protective bag , relay emergency valve relay inversion , system protection valve , winding starter generator field , hose radiator outlet to water pump

Corporations And Associations And Others

CTN :40937203 Due date: 10 Jul, 202510 Jul, 2025 4.74 Lacs
Tender For procurement of electrical material for day to day repair and maintenance at various ctcs (community toilet complexes) and pts (public toilets) under south zone (for swachhta survekshan - 2025) - rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required.group c, supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3x1.5 sq. mm, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3x2.5 sq. mm, supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required. (a)5/6 amps switch, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 3 pin 5/6 a socket outlet, supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 a socket outlet and 15/16 a piano type switch, connections, painting etc. as required., installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.upto 450 mm sweep, supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole, supplying and fixing following rating ,double pole,240 volt,isolator in the existing mcb db complete with connections,testing and commissioning etc. as required.(b) 63 amps, supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan fresh air type complete with shutter blades etc. as required., supplying, installation, testing & commissioning of led surface mountedbatten light of following body material and construction as per is : 10322with driver (replaceable) as per the requirement with driver efficiency>85% ,operating voltage ac 140-270 volt, freq 50/60 hz, operating temprange -15 deg to 40 deg centigrade, internal surge protection of 2.5 kv withshort & open circuit protection ,thd 10% , p. f. 0.95, ip20, cri >80,flicker free, (flicker should be below 5 %), life time (led,driver & electricalcircuitary), of minimum 50000 burning hours with , 70% of initiallumen maintained till life ends, cct 3000 k / 4000 k / 5700 k/6000 k/6500 k (as per ansi bin), sdcm(standard deviation colormatching) 3, maximum power consumption should not more than thespecified rating and fixture shall be of relevant bis standard and trademark certificate ( t.c.). manufactures word mark/ name engraved/embossing/ screen printing on housing. complete in all respect i/cconnections with 1.5 sq mm frls, pvc insulated copper conductorsingle core cable and earthing etc. as required with minimum 5 year oemwarranty. system lumen efficacy 105 120 lm/watt output . lm79 & lm80test report from nabl lab for all testing required for led fixtures asper bis shall be submitted. shape size and cct shall be as approved byengineer-in-charge as per requirement. (thermal management: heat sinkof aluminum housing such that led junction temperature shall not riseabove 90 c). 18- 22 watt, supply,installation,testing and commissioning of single /three phase monoblock pumpset complete with all accessories workable on 240/
 Loading, Please wait...

Connect us via What's Up